Juha Matti Kortelainen

Mr. Juha Matti Kortelainen


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2010 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
JKJuha Matti Kortelainen
Juha Matti Kortelainen
MMMartin O Mendez
Martin O Mendez
Anna Maria BianchiAnna Maria Bianchi
Anna Maria Bianchi
MMMatteo Matteucci
Matteo Matteucci
SCSergio Cerutti
Sergio Cerutti
We describe a system for the evaluation of the sleep macrostructure on the basis of Emfit sensor foils placed into bed mattress and of advanced signal processing. The signals on which the analysis is based are heart-beat interval (HBI) and movement activity obtained from the bed sensor, the relevant features and parameters obtained through a time-variant autoregressive model (TVAM) used as feature extractor, and the classification obtained through a hidden Markov model (HMM). Parameters coming from the joint probability of the HBI features were used as input to a HMM, while movement features are used for wake period detection. A total of 18 recordings from healthy subjects, including also reference polysomnography, were used for the validation of the system. When compared to wake-nonrapid-eye-movement (NREM)-REM classification provided by experts, the described system achieved a total accuracy of 79±9% and a kappa index of 0.43±0.17 with only two HBI features and one movement parameter, and a total accuracy of 79±10% and a kappa index of 0.44±0.19 with three HBI features and one movement parameter. These results suggest that the combination of HBI and movement features could be a suitable alternative for sleep staging with the advantage of low cost and simplicity.

14 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ETEmmi Turppa
Emmi Turppa
JKJuha Matti Kortelainen
Juha Matti Kortelainen
OAOleg Antropov
Oleg Antropov
TKTero Kiuru
Tero Kiuru
Remote monitoring of vital signs for studying sleep is a user-friendly alternative to monitoring with sensors attached to the skin. For instance, remote monitoring can allow unconstrained movement during sleep, whereas detectors requiring a physical contact may detach and interrupt the measurement and affect sleep itself. This study evaluates the performance of a cost-effective frequency modulated continuous wave (FMCW) radar in remote monitoring of heart rate and respiration in scenarios resembling a set of normal and abnormal physiological conditions during sleep. We evaluate the vital signs of ten subjects in different lying positions during various tasks. Specifically, we aim for a broad range of both heart and respiration rates to replicate various real-life scenarios and to test the robustness of the selected vital sign extraction methods consisting of fast Fourier transform based cepstral and autocorrelation analyses. As compared to the reference signals obtained using Embla titanium, a certified medical device, we achieved an overall relative mean absolute error of 3.6% (86% correlation) and 9.1% (91% correlation) for the heart rate and respiration rate, respectively. Our results promote radar-based clinical monitoring by showing that the proposed radar technology and signal processing methods accurately capture even such alarming vital signs as minimal respiration. Furthermore, we show that common parameters for heart rate variability can also be accurately extracted from the radar signal, enabling further sleep analyses.

1 August 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
JKJuha Matti Kortelainen
Juha Matti Kortelainen
JVJussi Virkkala
Jussi Virkkala
A multichannel pressure sensing Emfit foil was integrated to a bed mattress for measuring ballistocardiograph signals during sleep. We calculated the heart beat interval with cepstrum method, by applying FFT for short time windows including pair of consequent heart beats. We decreased the variance of FFT by averaging the multichannel data in the frequency domain. Relative error of our method in reference to electrocardiograph RR interval was only 0.35% for 15 night recordings with six normal subjects, when 12% of data was automatically removed due to movement artifacts. Background motivation for this work is given from the studies applying heart rate variability for the sleep staging.

15 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DCDavide Coluzzi
Davide Coluzzi
Giuseppe BaselliGiuseppe Baselli
Giuseppe Baselli
Anna Maria BianchiAnna Maria Bianchi
Anna Maria Bianchi
GGGuillermina Guerrero-Mora
Guillermina Guerrero-Mora
JKJuha Matti Kortelainen
Juha Matti Kortelainen
MMMartin Oswaldo Mendez
Martin Oswaldo Mendez
Sleep disorders are a growing threat nowadays as they are linked to neurological, cardiovascular and metabolic diseases. The gold standard methodology for sleep study is polysomnography (PSG), an intrusive and onerous technique that can disrupt normal routines. In this perspective, m-Health technologies offer an unobtrusive and rapid solution for home monitoring. We developed a multi-scale method based on motion signal extracted from an unobtrusive device to evaluate sleep behavior. Data used in this study were collected during two different acquisition campaigns by using a Pressure Bed Sensor (PBS). The first one was carried out with 22 subjects for sleep problems, and the second one comprises 11 healthy shift workers. All underwent full PSG and PBS recordings. The algorithm consists of extracting sleep quality and fragmentation indexes correlating to clinical metrics. In particular, the method classifies sleep windows of 1-s of the motion signal into: displacement (DI), quiet sleep (QS), disrupted sleep (DS) and absence from the bed (ABS). QS proved to be positively correlated (0.72±0.014) to Sleep Efficiency (SE) and DS/DI positively correlated (0.85±0.007) to the Apnea-Hypopnea Index (AHI). The work proved to be potentially helpful in the early investigation of sleep in the home environment. The minimized intrusiveness of the device together with a low complexity and good performance might provide valuable indications for the home monitoring of sleep disorders and for subjects’ awareness.

8 June 2011 in International Journal of Intelligent Transportation Systems Research
Verified
Journal Article
Closed access
PDF file
MDMikio Danno
Mikio Danno
MKMatti Kutila
Matti Kutila
JKJuha Matti Kortelainen
Juha Matti Kortelainen