Masazumi Fujiwara

Prof. Masazumi Fujiwara

Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
Masazumi FujiwaraMasazumi Fujiwara
Masazumi Fujiwara
SSSimo Sun
Simo Sun
ADAlexander Dohms
Alexander Dohms
YNYushi Nishimura
Yushi Nishimura
KSKen Suto
Ken Suto
EKEriko Kage-Nakadai
Eriko Kage-Nakadai
Real-time temperature monitoring inside living organisms provides a direct measure of their biological activities. However, it is challenging to reduce the size of biocompatible thermometers down to submicrometers, despite their potential applications for the thermal imaging of subtissue structures with single-cell resolution. Here, using quantum nanothermometers based on optically accessible electron spins in nanodiamonds, we demonstrate in vivo real-time temperature monitoring inside Caenorhabditis elegans worms. We developed a microscope system that integrates a quick-docking sample chamber, particle tracking, and an error correction filter for temperature monitoring of mobile nanodiamonds inside live adult worms with a precision of ±0.22°C. With this system, we determined temperature increases based on the worms’ thermogenic responses during the chemical stimuli of mitochondrial uncouplers. Our technique demonstrates the submicrometer localization of temperature information in living animals and direct identification of their pharmacological thermogenesis, which may allow for quantification of their biological activities based on temperature.

6 September 2011 in Nano Letters
Verified
Journal Article
Closed access
Masazumi FujiwaraMasazumi Fujiwara
Masazumi Fujiwara
KTKiyota Toubaru
Kiyota Toubaru
TNTetsuya Noda
Tetsuya Noda
HZHong-Quan Zhao
Hong-Quan Zhao
STShigeki Takeuchi
Shigeki Takeuchi

8 September 2021 in Nanotechnology
Verified
Journal Article
Open access
Masazumi FujiwaraMasazumi Fujiwara
Masazumi Fujiwara
YSYutaka Shikano
Yutaka Shikano
Diamond quantum thermometry exploits the optical and electrical spin properties of colour defect centres in diamonds and, acts as a quantum sensing method exhibiting ultrahigh precision and robustness. Compared to the existing luminescent nanothermometry techniques, a diamond quantum thermometer can be operated over a wide temperature range and a sensor spatial scale ranging from nanometres to micrometres. Further, diamond quantum thermometry is employed in several applications, including electronics and biology, to explore these fields with nanoscale temperature measurements. This review covers the operational principles of diamond quantum thermometry for spin-based and all-optical methods, material development of diamonds with a focus on thermometry, and examples of applications in electrical and biological systems with demand-based technological requirements.

23 April 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
TSTim Schröder
Tim Schröder
Masazumi FujiwaraMasazumi Fujiwara
Masazumi Fujiwara
TNTetsuya Noda
Tetsuya Noda
HZHong-Quan Zhao
Hong-Quan Zhao
OBOliver Benson
Oliver Benson
STShigeki Takeuchi
Shigeki Takeuchi
We present a fiber-coupled diamond-based single photon system. Single nanodiamonds containing nitrogen vacancy defect centers are deposited on a tapered fiber of 273 nanometer in diameter providing a record-high number of 689,000 single photons per second from a defect center in a single-mode fiber. The system can be cooled to cryogenic temperatures and coupled evanescently to other nanophotonic structures, such as microresonators. The system is suitable for integrated quantum transmission experiments, two-photon interference, quantum-random-number generation and nano-magnetometry.

6 May 2015 in Scientific Reports
Verified
Journal Article
Open access
ASAndreas W. Schell
Andreas W. Schell
HTHideaki Takashima
Hideaki Takashima
SKShunya Kamioka
Shunya Kamioka
YOYasuko Oe
Yasuko Oe
Masazumi FujiwaraMasazumi Fujiwara
Masazumi Fujiwara
STShigeki Takeuchi
Shigeki Takeuchi
Solid-state microcavities combining ultra-small mode volume, wide-range resonance frequency tuning, as well as lossless coupling to a single mode fibre are integral tools for nanophotonics and quantum networks. We developed an integrated system providing all of these three indispensable properties. It consists of a nanofibre Bragg cavity (NFBC) with the mode volume of under 1 μm3 and repeatable tuning capability over more than 20 nm at visible wavelengths. In order to demonstrate quantum light-matter interaction, we establish coupling of quantum dots to our tunable NFBC and achieve an emission enhancement by a factor of 2.7.

3 April 2020 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
Hiroshi YukawaHiroshi Yukawa
Hiroshi Yukawa
Masazumi FujiwaraMasazumi Fujiwara
Masazumi Fujiwara
KKKaori Kobayashi
Kaori Kobayashi
YKYuka Kumon
Yuka Kumon
KMKazu Miyaji
Kazu Miyaji
YBYoshinobu Baba
Yoshinobu Baba
Intracellular thermometry techniques play an important role in elucidating the relationship between the intracellular temperature and stem cell functions. However, there have been few reports on thermometry techniques that can detect the intracellular temperature of cells during several days of incubation. In this study, we developed a novel quantum thermometric sensing and analysis system (QTAS) using fluorescent nanodiamonds (FNDs). FNDs could label adipose tissue-derived stem cells (ASCs) at high efficiency with 24 h of incubation, and no cytotoxicity was observed in ASCs labeled with less than 500 μg mL−1 of FNDs. The peak of FNDs was confirmed at approximately 2.87 GHz with the characteristic fluorescence spectra of NV centers that could be optically detected (optically detected magnetic resonance [ODMR]). The ODMR peak clearly shifted to the high-frequency side as the temperature decreased and gave a mean temperature dependence of −(77.6 ± 11.0) kHz °C−1, thus the intracellular temperature of living ASCs during several days of culturing could be precisely measured using the QTAS. Moreover, the intracellular temperature was found to influence the production of growth factors and the degree of differentiation into adipocytes and osteocytes. These data suggest that the QTAS can be used to investigate the relationship between intracellular temperature and cellular functions.