OBJECTIVE. Precise assessment of the complex nerve-vessel relationship at the root entry zone of the trigeminal nerve is useful for planning microvascul
Object: The precise preoperative assessment of the complex nerve–vessel relationship at the root exit zone (RExZ) of the facial nerve is important when planning microvascular decompression (MVD) in patients with hemifacial spasms. The authors have developed an imaging technique—the fusion of 3D magnetic resonance (MR) cisternography and coregistered 3D MR angiography images—that allows clear visualization of the spatial relationship between the vessels and the rootlet of the facial nerve at the brainstem. Methods: The authors reconstructed 3D MR cisternograms and 3D MR angiograms by using a perspective volume-rendering algorithm that they applied to the volumetric data sets of the following modalities: MR cisternography (a T2-weighted 3D fast spin echo sequence) and coregistered MR angiography (a 3D time-of-flight sequence). The complex anatomical relationship between the offending vessels and the facial nerve RExZ was inspected preoperatively by examining the fusion images from various perspectives within the cerebellopontine angle cistern, within the affected facial nerve, and through the simulated surgical route. The reconstructed 3D findings of the nerve–vessel relationship were compared with the intraoperative findings. Postoperatively, the fused 3D MR imaging technique was used to confirm that microsurgical dissection and the interposed prosthesis had succeeded in maintaining the causative vessels in a position away from the RExZ. Conclusions: The fusion of 3D MR cisternograms and 3D MR angiograms may prove useful in the pre- and postoperative assessment of MVD in patients with hemifacial spasm.
27 November 2008 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Neurovascular contact (NVC) of the trigeminal nerve is not only detected at the affected trigeminal nerve in patients with trigeminal neuralgia (TN) but is also observed at the asymptomatic nerves on the side contralateral to the TN as well as in normal nerves in control subjects. The frequency and severity of the NVC among the affected, contralateral, and normal trigeminal nerves were analyzed by 3D MR cisternogram and angiogram fusion imaging in relation to the cause of TN. MATERIALS AND METHODS: The inner view of the fusion MR imaging projected from inside the trigeminal nerve was used. The severity of the NVC was classified as none, simple, moderate, or severe, according to the nerve circumference in contact with the vessel. The NVC was analyzed in the affected nerves (n = 66) and the contralateral nerves (n = 66). Forty patients underwent microvascular decompression surgery, and 26 were treated medically. The NVC at the normal trigeminal nerves (n = 78) was studied in 39 control subjects without symptoms of TN. RESULTS: The NVC in the affected trigeminal nerve was observed more frequently and much more severely than that at the contralateral and normal trigeminal nerves in controls (P < .01). Additionally, the NVC in the surgical patients was more severe than that in the medically treated patients (P < .01). CONCLUSIONS: Severity analysis of the NVC with the inner view of the fusion MR imaging may provide useful information in the diagnosis of TN and can be a helpful adjunct in treatment planning for patients with TN.
4 April 2019 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Our aim was to visualize the precise configuration of the aneurysmal neck and dome with/without remnants combined with a coiled dome after coiling treatment for cerebral aneurysms. We developed 3D multifusion imaging of silent MRA and FSE-MR cisternography. MATERIALS AND METHODS: We examined 12 patients with 3D multifusion imaging by composing 3D images reconstructed from TOF-MRA, silent MRA, and FSE-MR cisternography. The influence of magnetic susceptibility artifacts caused by metal materials affecting the configuration of the aneurysmal complex with coiling was assessed in a single 3D image. RESULTS: In all cases, TOF-MRA failed to depict the aneurysmal neck complex precisely due to metal artifacts, whereas silent MRA delineated the neck and parent arteries at the coiled regions without serious metal artifacts. FSE-MR cisternography depicted the shape of the coiled aneurysmal dome and parent artery complex together with the brain parenchyma. With the 3D multifusion images of silent MRA and FSE-MR cisternography, the morphologic status of the coiled neck and parent arteries was clearly visualized with the shape of the dome in a single 3D image. CONCLUSIONS: Silent MRA is a non-contrast-enhanced form of MRA. It depicts the coiled neck complex without serious metal artifacts. FSE-MR cisternography can delineate the shape of the coiled dome. In this small feasibility study, 3D multifusion imaging of silent MRA and FSE-MR cisternography allowed good visualization of key features of coiled aneurysms. This technique may be useful in the follow-up of coiled aneurysms.
OBJECTIVE: Offending vessels at the site of neurovascular contact (NVC) in patients with trigeminal neuralgia (TN) and hemifacial spasm (HFS) may have specific hemodynamic features. The purpose of this study was to investigate the wall shear stress (WSS) of offending vessels at NVCs by conducting a computational fluid dynamics (CFD) analysis. METHODS: The authors retrospectively analyzed the cases of 20 patients (10 with TN and 10 with HFS) evaluated by 3D CT angiography and used the imaging findings for analysis of the hemodynamic parameters. The 3D CFD images were directly compared with the NVCs determined by simulated multifusion images of CT angiogram and MR cisternogram, and operative photos. The magnitudes of the WSS (WSSm) at the proximal (WSSm-p), just-beginning (WSSm-j), contact site (WSSm-s), and distal (WSSm-d) areas of each NVC were analyzed. The ratios of the WSSm-j, WSSm-s, and WSSm-d areas to the WSSm-p area were calculated individually. The direction of the WSS (WSSv) and its temporal variation (WSSvV) were depicted and morphologically compared with the NVC confirmed by simulated images and operative findings. RESULTS: The ratios of WSSm at the just-beginning and the contact site to the proximal area of the NVCs (WSSm-j/WSSm-p and WSSm-s/WSSm-p) were both significantly higher than that at the distal area (WSSm-d/WSSm-p) (p < 0.05). The WSSv and WSSvV at the NVCs showed small variation in a single cardiac cycle, especially along the areas that were in contact with the affected nerve. CONCLUSIONS: Areas of relatively high WSSm and temporal variation of WSSm (WSSmV) were observed at the NVCs. Less mobility of the WSSv and WSSvV was detected along the side of the vessels in contact with the nerves. These findings may be consistent with the actual area of the NVC. Hemodynamic features of the site of NVC can be added to the preoperative simulation for MVD surgery, which may be useful for the diagnosis and treatment planning of TN and HFS.
The mechanism of bleb formation in unruptured intracranial aneurysms (UIAs) remains unclear. This study aimed to investigate the association between peri-aneurysmal contact (PAC) and bleb formation. Forty-five aneurysms were classified depending on the presence of blebs and PAC using computed tomographic angiography and magnetic resonance imaging. Aneurysmal hemodynamics were assessed using computational fluid dynamics. The independent variables associated with bleb formation were statistically assessed. Fourteen aneurysms (31.1%) had blebs, all of which were located at the site of PAC (group A). Thirty-one aneurysms (68.9%) had no bleb, of which 13 had a PAC (group B) and 18 had no PAC (group C). PAC was the only independent variable associated with bleb formation (p < 0.05). Aneurysmal volumes were significantly higher in group A, followed by groups B and C in series. Aneurysmal wall shear stress (WSS) tended to be lowest in group A, followed by groups B and C in series. The maximum WSS at the blebs was only 17% of the maximum WSS at the aneurysmal domes. This study demonstrated that bleb formation in UIAs was associated with the establishment of PAC during their growth, which may have more detrimental effects on bleb formation than hemodynamics.