The health of the hydroelectric generator determines the safe, stable, and reliable operation of the hydropower station. In order to keep the hydroelectric generator in a better state of health and avoid accidents, it is crucial to detect its faults. In recent years, fault detection methods based on sound and vibration signals have gradually become research hotspots due to their high sensitivity, achievable continuous dynamic monitoring, and easy adaptation to complex environments. Therefore, this paper is a supplement to the existing state monitoring and fault diagnosis system of the hydroelectric generator; it divides the hydroelectric generator into two significant parts: hydro-generator and hydro-turbine, and summarizes the research and application of fault detect technology based on sound signal vibration in hydroelectric generator and introduces some new technology developments in recent years, and puts forward the existing problems in the current research and future development directions, and it is expected to provides some reference for the research on fault diagnosis of the hydroelectric generator.
This paper proposes a new cascaded fractional-order controller (CC-FOC) to solve the load frequency control (LFC) problem of an interconnected power system. The CC-FOC consists of a three-degree-of-freedom fractional-order proportional-integral-differential (3DOF-FOPID) controller and a fractional-order proportional-integral (FOPI) controller. Each area of the two-area interconnected power system in this study consists of a thermal unit, a hydro unit, a diesel unit, and a doubly-fed induction generator (DFIG). The enhanced particle swarm optimization (PSO) and gravitational search algorithm (GSA) under the chaotic map optimization (CPSOGSA) technique are used to optimize the controller gains and parameters to enhance the load frequency control performance of the cascade controller. Moreover, simulation experiments are conducted for the interconnected power system under load perturbation and random wind speed fluctuations. The simulation results demonstrate that the proposed cascaded fractional-order controller outperforms the traditional proportional-integral-differential (PID) controller and three other fractional-order controllers in terms of LFC performance. The suggested cascade controller displays strong dynamic control performance and the resilience of the cascade fractional-order controller by adjusting the load disturbance and analyzing the system characteristics.
The hydraulic turbine governing system (HTGS) is a complex nonlinear system that regulates the rotational speed and power of a hydro-generator set. In this work, an incremental form of an HTGS nonlinear model was established and the Takagi–Sugeno (T-S) fuzzy linearization and mixed H2/H∞ robust control theory was applied to the design of an HTGS controller. A T-S fuzzy H2/H∞ controller for an HTGS based on modified hybrid particle swarm optimization and gravitational search algorithm integrated with chaotic maps (CPSOGSA) is proposed in this paper. The T-S fuzzy model of an HTGS that integrates multiple-state space equations was established by linearizing numerous equilibrium points. The linear matrix inequality (LMI) toolbox in MATLAB was used to solve the mixed H2/H∞ feedback coefficients using the CPSOGSA intelligent algorithm to optimize the weighting matrix in the process so that each mixed H2/H∞ feedback coefficients in the fuzzy control were optimized under the constraints to improve the performance of the controller. The simulation results show that this method allows the HTGS to perform well in suppressing system frequency deviations. In addition, the robustness of the method to system parameter variations is also verified.
The penetration of distributed generators (DGs)-based power electronic devices leads to low inertia and damping properties of the modern power grid. As a result, the system becomes more susceptible to disruption and instability, particularly when the power demand changes during critical loads or the system needs to switch from standalone to a grid-connected operation mode or vice versa. Developing a robust controller to deal with these transient cases is a real challenge. The inverter control method via the virtual synchronous generator (VSG) control method is a better way to supply the system’s inertia and damping features to boost system stability. Therefore, a nonlinear control strategy for VSG with uncertain disturbance is proposed in this paper to enhance the system stability in the islanded, grid-connected, and transition modes. Firstly, the mechanical equations for a VSG’s rotor, which include virtual inertia and damping coefficient, are presented, and the matching mathematical model is produced. Then, the nonlinear backstepping controller (BSC) method combined with the extended state observer (ESO) is constructed to compensate for the uncertainty. The Lyapunov criteria were used to prove the method’s stability. Considering the issue of uncertain items, a second-order ESO is built to estimate uncertainty and external disruption. Finally, the suggested control strategy is validated through three simulation experiments; the findings reveal that the proposed control method has an excellent performance with fast response and tracking under various operating situations.
To address the problem that the hydraulic turbine governing system (HTGS) exhibits poor anti-disturbance ability and instability phenomena under traditional PID control, an improved new integral sliding mode control strategy based on a nonlinear disturbance observer (NISMC-NDO) is designed for the HTGS. This study first establishes a nonlinear mathematical model of HTGS and analyzes its dynamic characteristics. The uncertain disturbances of the system are then accurately estimated using a disturbance observer, and a suitable nonlinear gain function is designed to achieve feedforward compensation of the controller by ensuring that the disturbance observation error converges. To design the controller, a proportional-integral sliding mode surface is selected, and the sliding mode exponential convergence law is improved by using the nonlinear power combination function instead of or . This improves the system’s stability, convergence speed, and tracking accuracy. The simulation results demonstrate that the equilibrium point can be quickly reached and stabilized by the HTGS with chaotic phenomena under the influence of NISMC-NDO. Furthermore, this paper also verifies that the designed controller has good dynamic performance. The findings of this study can serve as a valuable reference for optimizing the operation of hydraulic turbine regulation systems in control applications.
Invertor as a virtual synchronous generator (VSG) to provide virtual inertia and damping can improve the stability of a microgrid, in which the damping is one of the fundamental problems in dynamics. From the view of the Hamiltonian dynamics, this paper researches the damping formation mechanism and damping injection control of VSG. First, based on the energy composition and dynamic characteristics of VSG, the differential equations system of VSG is established and is transformed into the generalized Hamiltonian system. Second, the effects of the three parameters of VSG, the damping coefficient D, active power droop coefficient, and time constant of excitation TE on damping characteristics are researched from a dynamic perspective, and simulation research is carried out with an isolated microgrid. Lastly, the control design method of Hamiltonian structure corrections used to add the damping factor and design the equivalent control inject damping to improve the stability of the isolated microgrid. Research shows that the voltage and frequency stability of the isolated microgrid can be effectively improved by selecting three key parameters of VSG and damping injection control. The innovations of this paper are 1. The Hamiltonian model of the inverter is deduced and established by taking the inverter as a virtual generator. 2. Based on the Hamiltonian model, damping characteristics of inverter in the microgrid are studied. 3. Hamiltonian structure correction method is applied to the inverter, and equivalent damping injection is designed to improve the stability of the microgrid.