(1) Objective: To evaluate and compare the depth of cure (DOC) of two bulk-fill flowable composites (Filtek Bulk Fill Flowable Restorative and Tetric EvoFlow Bulk Fill), two conventional flowable composites (Filtek Supreme XTE Flowable Restorative and G-ænial Flo X) and one high-strength universal injectable composite (G-ænial Universal Injectable). (2) Methods: specimens were placed in a stainless-steel mold with an orifice of 4 mm in diameter and 10 mm in depth and light-cured for 20 s using a light emitting diode (LED) light-curing unit (LCU) with an irradiance of 1000 mW/cm2; depth of cure was assessed using the ISO 4049 scrape technique, and the absolute length of the specimen of cured composite was measured in millimeters with a digital caliper. The same procedure was repeated with 14 samples for each material under investigation, for a total number of 70 test bodies. Material roughness and hardness results were also investigated using, respectively, a 3D laser confocal microscope (LEXT OLS 4100; Olympus) at ×5 magnification and a Vickers diamond indenter (Vickers microhardness tester, Shimadzu®, Kyoto, Japan) under 10-N load and a 30 s dwell time. SEM images at 3000 and 9000 magnification were collected in order to study the materials’ filler content. Statistical analysis were performed by a commercial statistical software package (SPSS) and data were analyzed using multiple comparison Dunnett’s test. (3) Results: The average DOC of both bulk-fill composites was more than 4 mm, as a range of 3.91 and 4.53 mm with an average value of 4.24 and 4.12 mm, while that of the conventional flowable composites was much lower, as a range of 2.47 and 2.90 mm with an average value of 2.58 and 2.84 mm; DOC of the high-strength injectable composite was greater than the one of traditional composites, but not to the level of bulk-fill materials, as a range of 2.82 and 3.01 mm with an average value of 3.02 mm. Statistical analysis revealed significant differences (p-values < 0.05) in the depth of cure between bulk fill flowable composites and other composites, while there was no difference (p-values > 0.05) between the materials of the same type. (4) Conclusions: Bulk-fill flowable composites showed significantly higher depth of cure values than both traditional flowable composites and high-strength injectable composites.
The aim of this study was to assess the influence of inclination of the object on the reliability and reproducibility of linear measurements of anatomic structures of the mandible on images obtained using cone-beam CT (CBCT). Ten linear dimensions between anatomical landmarks were measured in a dry mandible. The measurements were performed with a manual calliper three times by three observers. The mandible was scanned with Planmeca Promax 3D cone-beam CT (Planmeca Oy, Helsinki, Finland) with the base of the mandible parallel as well as tilted 45° to the horizontal plane. Computer measurements of the linear dimension were performed by three observers. The radiographic measurements were performed four times for each experimental setting. A total of 240 measurements were performed. Reproducibility was evaluated through comparison of standard deviation (SD) and estimation of intraclass correlation coefficient (ICC). The error was estimated as the absolute difference between the radiographic measurements and the mean manual calliper measurements. The mean SD for the radiographic measurements was 0.36 mm for the horizontally positioned mandible and 0.48 mm for the inclined mandible. The ICC between examiners was 0.996 mm, between sessions was 0.990 mm and between CBCT measurements and calliper was 0.992 mm. The overall absolute mean measurement error was 0.40 mm (SD 0.39 mm). The percentage of errors that exceeded 1 mm was 6.7%. The results revealed high reliability of measurements performed on CBCT images independently from object position, examiner's experience and high reproducibility in repeated measurements settings.
One hundred and eleven children admitted with suspected gastro-oesophageal reflux were studied, with 24 hour oesophageal pH monitoring as the first line of investigation. Barium swallow examination, or oesophagoscopy, or both, were carried out only in children with abnormal pH, who subsequently had a trial of 1-12 months medical treatment. All patients were followed up for eight months to two years. A final diagnosis of gastro-oesophageal reflux was made in 41 patients, in all of whom the pH study was abnormal (100% sensitivity). The final diagnosis was different in 70 patients; 66 of these had a normal pH (94% specificity). All children with gastro-oesophageal reflux were treated with drugs. All those with a percentage reflux time of more than 27 and more than 20 episodes of reflux lasting more than 5 minutes failed to improve and needed operation. We conclude that monitoring of the oesophageal pH should be the first line of investigation in patients with gastro-oesophageal reflux and should be used together with clinical data and other investigations, to identify those children who will need operation.
Introduction: The oral cavity and the teeth are frequently subjected to numerous physiological pH variations, mainly due to the type of diet. These changes are the main cause of enamel demineralization and consequent breakage under mechanical forces. This causes severe sensitivity and sometimes pain, which endures unless the hard tissue is remineralized. Since enamel does not self-repair, the application of alloplastic materials that have the property of releasing remineralizing ions is strongly recommended. The aim of this in vitro study is to evaluate the effectiveness of two different toothpastes and a fluoride varnish in the prevention of demineralization, and their ability to remineralize enamel after it has undergone several acidifications. Methods: Eight human teeth with no caries or defects were prepared. The acid attack simulations were performed using a commercial cola carbonated drink. Samples were immersed in 5 mL of soft drink for two minutes at room temperature, and then were rinsed with distilled/deionized water. The immersion process lasted about 2 min, and was repeated four times for a total of eight minutes. Then, two different types of toothpaste, one with and one without fluoride, and a fluoride varnish were applied to the surfaces of the samples and rinsed off with demineralized water. A second acidification cycle was then carried out, with the subsequent reapplication of the three different products to evaluate their ability to protect against demineralization. SEM and profilometer analysis were then carried out to evaluate the results. Results: The statistical analysis showed a good remineralization capacity for all three products, especially in the fluoride-varnish-treated samples. However, regarding protection from demineralization, non-fluoride toothpaste was found to be ineffective, while fluoride toothpaste and varnish produced positive results. Conclusions: Dental professionals should advise fluoride toothpastes and varnishes over non-fluoride toothpastes. Fluoride toothpastes and varnishes represent a valid treatment for surface remineralization after a first acid attack and for protection from subsequent demineralization in an acid environment, such as that which can develop in the oral cavity.
Pregnancy is a critical time for a woman since it involves a series of changes in the body due to hormonal fluctuations and changes that can also influence the oral cavity and can lead to certain pathologies, such as carious lesions. Furthermore, it has been demonstrated over the years that having poor dental health during pregnancy might have a significant impact on the child’s oral health. The aim of the study is to analyze the level of knowledge and information of mothers on the importance of oral health care before, during, and after pregnancy as a preventive factor for the future oral health of the child. A questionnaire of 13 multiple choice questions was formulated and delivered from 24 February 2022 to 13 July 2022, aimed at women with at least one child. The Department of Pediatric Dentistry of the Borgo Cavalli Clinic in Treviso and the Maxillofacial Surgery Department of Santa Maria di Ca’ Foncello Hospital in Treviso were the data collection centers. Crosstabs with dependency variables were used to statistically analyze the results. The study cohort consists of 411 women, whose responses showed that the majority did not have dental visits before and during pregnancy, which is why 74% of the whole sample did not request or receive information from professionals. Most mothers knew that they had to cleanse their child’s mouth and, among them, those who responded more correctly, that is, who started before the eruption of the teeth, had received instructions from professionals. However, the low frequency of mothers performing dental checks during pregnancy did not allow mothers to become aware of the possibility of transmitting the carious lesions to their child, as conscious mothers represent 21%. Education from dentist and dental hygienists, gynecologists, and pediatricians is essential since they have an impact on mothers’ habits and behaviors and ensure favorable oral health for both the mother and the child.