Shariq Suleman

Mr. Shariq Suleman

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SMShouvik Mukherjee
Shouvik Mukherjee
SSShariq Suleman
Shariq Suleman
Roberto PillotonRoberto Pilloton
Roberto Pilloton
JNJagriti Narang
Jagriti Narang
Kirti RaniKirti Rani
Kirti Rani
Several illnesses that are chronic and acute are becoming more relevant as the world’s aging population expands, and the medical sector is transforming rapidly, as a consequence of which the need for “point-of-care” (POC), identification/detection, and real time management of health issues that have been required for a long time are increasing. Biomarkers are biological markers that help to detect status of health or disease. Biosensors’ applications are for screening for early detection, chronic disease treatment, health management, and well-being surveillance. Smart devices that allow continual monitoring of vital biomarkers for physiological health monitoring, medical diagnosis, and assessment are becoming increasingly widespread in a variety of applications, ranging from biomedical to healthcare systems of surveillance and monitoring. The term “smart” is used due to the ability of these devices to extract data with intelligence and in real time. Wearable, implantable, ingestible, and portable devices can all be considered smart devices; this is due to their ability of smart interpretation of data, through their smart sensors or biosensors and indicators. Wearable and portable devices have progressed more and more in the shape of various accessories, integrated clothes, and body attachments and inserts. Moreover, implantable and ingestible devices allow for the medical diagnosis and treatment of patients using tiny sensors and biomedical gadgets or devices have become available, thus increasing the quality and efficacy of medical treatments by a significant margin. This article summarizes the state of the art in portable, wearable, ingestible, and implantable devices for health status monitoring and disease management and their possible applications. It also identifies some new technologies that have the potential to contribute to the development of personalized care. Further, these devices are non-invasive in nature, providing information with accuracy and in given time, thus making these devices important for the future use of humanity.

28 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
NANIGAR ANZAR
NIGAR ANZAR
SSShariq Suleman
Shariq Suleman
RKRocky Kumar
Rocky Kumar
RRRachna Rawal
Rachna Rawal
CPC.S. Pundir
C.S. Pundir
Roberto PillotonRoberto Pilloton
Roberto Pilloton
A notable diagnostic for the detection of hemolytic diseases is bilirubin, a by-product of haemoglobin breakdown. The concentration of bilirubin ranges from 0.3 to 1.9 mg in 100 mL of blood. Low blood bilirubin levels are associated with a greater risk of coronary heart disease and anaemia. Hyperbilirubinemia results from a serum bilirubin level of more than 2.5 mg/100 mL. Therefore, it is very crucial to check the serum bilirubin level. Analytical equipment for point-of-care testing must be portable, small, and affordable. A unique method is used to detect bilirubin selectively using paper-based screen-printed carbon electrodes that were covalently linked with nanoparticles, that serves as a key biomarker for jaundice. In order to create an electrochemical biosensor, bilirubin oxidase was immobilised on electrodes modified with AgNPs. The morphology of Ag nanoparticles in terms of size and shape was determined using both UV- Vis Spectroscopy and transmission electron microscopy (TEM). The biosensor’s analytical response was assessed using potentiostat (Cyclic voltammetry (CV) and linear sweep voltammetry (LSV)). The developed paper-based sensor provided optimum feedback and a broad linear range of 1 to 9 µg/mL for bilirubin, with a lower LOD of 1 µg/mL. Through tests of bilirubin in artificial blood serum, the viability is confirmed. The method that is being used makes it possible to create and use an inexpensive, miniature electrochemical sensor.

3 October 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
NANIGAR ANZAR
NIGAR ANZAR
SSShariq Suleman
Shariq Suleman
YSYashda Singh
Yashda Singh
SKSupriya Kumari
Supriya Kumari
PSParvez Suhel
Parvez Suhel
JNJagriti Narang
Jagriti Narang
The increasing use of illicit drugs has become a major global concern. Illicit drugs interact with the brain and the body altering an individual’s mood and behavior. As the substance-of-abuse (SOA) crisis continues to spread across the world, in order to reduce trafficking and unlawful activity, it is important to use point-of-care devices like biosensors. Currently, there are certain conventional detection methods, which include gas chromatography (GC), mass spectrometry (MS), surface ionization, surface-enhanced Raman spectroscopy (SERS), surface plasmon resonance (SPR), electrochemiluminescence (ECL), high-performance liquid chromatography (HPLC), etc., for the detection of abused drugs. These methods have the advantage of high accuracy and sensitivity but are generally laborious, expensive, and require trained operators, along with high sample requirements, and they are not suitable for on-site drug detection scenarios. As a result, there is an urgent need for point-of-care technologies for a variety of drugs that can replace conventional techniques, such as a biosensor, specifically an immunosensor. An immunosensor is an analytical device that integrates an antibody-based recognition element with a transducer to detect specific molecules (antigens). In an immunosensor, the highly selective antigen–antibody interaction is used to identify and quantify the target analyte. The binding event between the antibody and antigen is converted by the transducer into a measurable signal, such as electrical, optical, or electrochemical, which corresponds to the presence and concentration of the analyte in the sample. This paper provides a comprehensive overview of various illicit drugs, the conventional methods employed for their detection, and the advantages of immunosensors over conventional techniques. It highlights the critical need for on-site detection and explores emerging point-of-care testing methods. The paper also outlines future research goals in this field, emphasizing the potential of advanced technologies to enhance the accuracy, efficiency, and convenience of drug detection.

24 February 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
SSShariq Suleman
Shariq Suleman
NANIGAR ANZAR
NIGAR ANZAR
SPShikha Patil
Shikha Patil
SHShadan
Shadan
PSParvez Suhel
Parvez Suhel
JNJagriti Narang
Jagriti Narang
Ketamine is one of the most commonly abused drugs globally, posing a severe risk to social stability and human health, not only it is being used for recreational purposes, but this tasteless, odourless, and colourless drug also facilitates sexual assaults when it is mixed with drinks. Ketamine abuse is a threat for safety, and this misuse is one of the main uses of the drug. The crucial role of ketamine detection is evident in its contributions to forensic investigations, law enforcement, drug control, workplace integrity, and public health. Electrochemical sensors have gained considerable interest among researchers due to their various advantages, such as low cost and specificity, and particularly screen-printed paper-based electrode (SPBE) biosensors have gained attention. Here, we reported an ePAD (electrochemical paper-based analytical device) for detecting the recreational drug ketamine. The advantages of using a paper-based electrode are that it reduces the electrode’s production costs and is disposable and environmentally friendly. At the same time, nanographite sheets (NGSs) assisted in amplifying the signals generated in the cyclic voltammetry system when ketamine was present. This ePAD was developed by immobilizing a ketamine aptamer on NGS electrodes. The characterization of proper synthesized NGSs was performed by Scanning Electron Microscopy (SEM), XRD (X-ray Diffraction), Fourier-transform infrared spectroscopy (FTIR), and UV-Vis spectroscopy. Electrochemical techniques, including cyclic voltammetry (CV) and linear sweep voltammetry (LSV), were employed to validate the results and confirm each attachment. Furthermore, the versatility of the proposed sensor was explored in both alcoholic and non-alcoholic beverages. The developed sensor showed a low LOD of about 0.01 μg/mL, and the linear range was between 0.01 and 5 μg/mL. This approach offers a valid diagnostic technique for onsite service with minimal resources. This cost effective and portable platform offers desirable characteristics like sensitivity and selectivity and can also be used for POC (point of care) testing to help in the quick identification of suspicious samples and for testing at trafficking sites, amusement parks, and by the side of the road.

12 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NANIGAR ANZAR
NIGAR ANZAR
SSShariq Suleman
Shariq Suleman
HBHusnara Bano
Husnara Bano
PSParvez Suhel
Parvez Suhel
MKManika Khanuja
Manika Khanuja
JNJagriti Narang
Jagriti Narang
We present the development of an electrochemical paper-based analytical device (ePAD) for the detection of methamphetamine. Methamphetamine is a stimulant that young people use as an addictive narcotic, and it must be detected quickly since it may be hazardous. The suggested ePAD has the advantages of being simple, affordable, and recyclable. This ePAD was developed by immobilizing a methamphetamine-binding aptamer onto Ag-ZnO nanocomposite electrodes. The Ag-ZnO nanocomposites were synthesized via a chemical method and were further characterized via scanning electron microscopy, Fourier transform infrared spectroscopy, and UV-vis spectrometry in terms of their size, shape, and colloidal activity. The developed sensor showed a limit of detection of about 0.1 μg/mL, with an optimum response time of about 25 s, and its extensive linear range was between 0.01 and 6 μg/mL. The application of the sensor was recognized by spiking different beverages with methamphetamine. The developed sensor has a shelf life of about 30 days. This cost-effective and portable platform might prove to be highly successful in forensic diagnostic applications and will benefit those who cannot afford expensive medical tests.

18 October 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
NANIGAR ANZAR
NIGAR ANZAR
SSShariq Suleman
Shariq Suleman
YSYashda Singh
Yashda Singh
PSParvez Suhel
Parvez Suhel
MKManika Khanuja
Manika Khanuja
JNJagriti Narang
Jagriti Narang
Illicit drug misuse has become a widespread issue that requires continuous drug monitoring and diagnosis. Wearable electrochemical drug detection devices possess the potential to function as potent screening instruments in the possession of law enforcement personnel, aiding in the fight against drug trafficking and facilitating forensic investigations conducted on site. These wearable sensors are promising alternatives to traditional detection methods. In this study, we present a novel wearable electrochemical glove-based analytical device (eGAD) designed especially for detecting the club drug, methamphetamine. To develop this sensor, we immobilized meth aptamer onto silver nanoparticle (AgNPs)-modified electrodes that were printed onto latex gloves. The characteristics of AgNPs, including their shape, size and purity were analysed using FTIR, SEM and UV vis spectrometry, confirming the successful synthesis. The developed sensor shows a 0.1 µg/mL limit of detection and 0.3 µg/mL limit of quantification with a linear concentration range of about 0.01–5 µg/mL and recovery percentages of approximately 102 and 103%, respectively. To demonstrate its applicability, we tested the developed wearable sensor by spiking various alcoholic and non-alcoholic drink samples. We found that the sensor remains effective for 60 days, making it a practical option with a reasonable shelf-life. The developed sensor offers several advantages, including its affordability, ease of handling and high sensitivity and selectivity. Its portable nature makes it an ideal tool for rapid detection of METH in beverages too.