Praveen Pankajakshan

Dr. Praveen Pankajakshan

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2012 in Nature Methods
Verified
Journal Article
Closed access
FCFabrice de Chaumont
Fabrice de Chaumont
SDStéphane Dallongeville
Stéphane Dallongeville
NCNicolas Chenouard
Nicolas Chenouard
NHNicolas Hervé
Nicolas Hervé
SPSorin Pop
Sorin Pop
JOJean-Christophe Olivo-Marin
Jean-Christophe Olivo-Marin

4 May 2017 in Chemistry of Materials
Verified
Journal Article
Closed access
PPPraveen Pankajakshan
Praveen Pankajakshan
SSSuchismita Sanyal
Suchismita Sanyal
ONOnno E. de Noord
Onno E. de Noord
IBIndranil Bhattacharya
Indranil Bhattacharya
ABArnab Bhattacharyya
Arnab Bhattacharyya
UWUmesh Waghmare
Umesh Waghmare

27 July 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
PPPraveen Pankajakshan
Praveen Pankajakshan
BZBo Zhang
Bo Zhang
LBLaure Blanc-Féraud
Laure Blanc-Féraud
ZKZvi Kam
Zvi Kam
JOJean-Christophe Olivo-Marin
Jean-Christophe Olivo-Marin
JZJosiane Zerubia
Josiane Zerubia
We propose an alternate minimization algorithm for estimating the point-spread function (PSF) of a confocal laser scanning microscope and the specimen fluorescence distribution. A three-dimensional separable Gaussian model is used to restrict the PSF solution space and a constraint on the specimen is used so as to favor the stabilization and convergence of the algorithm. The results obtained from the simulation show that the PSF can be estimated to a high degree of accuracy, and those on real data show better deconvolution as compared to a full theoretical PSF model.

10 December 2018 in Chemistry of Materials
Verified
Journal Article
Closed access
NKNarendra Kumar
Narendra Kumar
PRPadmini Rajagopalan
Padmini Rajagopalan
PPPraveen Pankajakshan
Praveen Pankajakshan
ABArnab Bhattacharyya
Arnab Bhattacharyya
SSSuchismita Sanyal
Suchismita Sanyal
UWUmesh V. Waghmare
Umesh V. Waghmare

1 June 2009
Verified
Conference Paper
Closed access
PPPraveen Pankajakshan
Praveen Pankajakshan
LBLaure Blanc-Feraud
Laure Blanc-Feraud
ZKZvi Kam
Zvi Kam
JZJosiane Zerubia
Josiane Zerubia
In this paper we propose a method for retrieving the Point Spread Function (PSF) of an imaging system given the observed image sections of a fluorescent microsphere. Theoretically calculated PSFs often lack the experimental or microscope specific signatures while empirically obtained data are either over sized or (and) too noisy. The effect of noise and the influence of the microsphere size can be mitigated from the experimental data by using a Maximum Likelihood Expectation Maximization (MLEM) algorithm. The true experimental parameters can then be estimated by fitting the result to a model based on the scalar diffraction theory with lower order Spherical Aberration (SA). The algorithm was tested on some simulated data and the results obtained validate the usefulness of the approach for retrieving the PSF from measured data.

1 August 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
PPPraveen Pankajakshan
Praveen Pankajakshan
BZBo Zhang
Bo Zhang
LBLaure Blanc-Feraud
Laure Blanc-Feraud
ZKZvi Kam
Zvi Kam
JOJean-Christophe Olivo-Marin
Jean-Christophe Olivo-Marin
JZJosiane Zerubia
Josiane Zerubia
In this paper, we propose a method for the iterative restoration of fluorescence confocal laser scanning microscopic (CLSM) images and parametric estimation of the acquisition system's point spread function (PSF). The CLSM is an optical fluorescence microscope that scans a specimen in 3D and uses a pinhole to reject most of the out-of-focus light. However, the quality of the images suffers from two basic physical limitations. The diffraction-limited nature of the optical system, and the reduced amount of light detected by the photomultiplier cause blur and photon counting noise respectively. These images can hence benefit from post-processing restoration methods based on deconvolution. An efficient method for parametric blind image deconvolution involves the simultaneous estimation of the specimen 3D distribution of fluorescent sources and the microscope PSF. By using a model for the microscope image acquisition physical process, we reduce the number of free parameters describing the PSF and introduce constraints. The parameters of the PSF may vary during the course of experimentation, and so they have to be estimated directly from the observed data. A priori model of the specimen is further applied to stabilize the alternate minimization algorithm and to converge to the solutions.