Yongji Liu

Dr. Yongji Liu

Institue of Modern Optics, College of Electronic Information and Optical Engineering, Nankai University, Tianjin, China
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2012 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
Yongji LiuYongji Liu
Yongji Liu
YWYan Wang
Yan Wang
ZWZhaoqi Wang
Zhaoqi Wang
TZTong Zuo
Tong Zuo

22 May 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
YXYuwei Xing
Yuwei Xing
Yongji LiuYongji Liu
Yongji Liu
KLkq li
kq li
XLXiaolan Li
Xiaolan Li
DLDongyu Liu
Dongyu Liu
YWYan Wang
Yan Wang
An approach is presented to design different types of Intraocular lenses (IOLs) with a uniform optimization algorithm. An improved sinusoidal phase function is proposed to realize adjustable energy allocations in different diffractive orders according to the design aims. By setting specific optimization goals, different types of IOLs can be designed using the same optimization algorithm. With this method, bifocal, trifocal, extended-depth-of-focus (EDoF), and mono-EDoF IOLs are successfully designed and their optical performance under monochromatic and polychromatic light is evaluated and compared with their commercial counterparts. The result shows that most of the designed IOLs, even though they don’t have any multi-zones or combination of diffractive profiles, have superior or comparable performance to their commercial counterparts in terms of optical performance under monochromatic light. The result demonstrates the validity and reliability of the approach proposed in this paper. With this method, the development time of different types of IOLs could be reduced considerably.

25 August 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
Yongji LiuYongji Liu
Yongji Liu
XLXiaolan Li
Xiaolan Li
LZLin Zhang
Lin Zhang
XYXianglong Yi
Xianglong Yi
YXYuwei Xing
Yuwei Xing
YWYan Wang
Yan Wang
Wavefront aberrations in the image space are critical for visual perception, though the clinical available instruments usually give the wavefront aberrations in the object space. This study aims to compare the aberrations in the object and image spaces. With the measured wavefront aberrations over the horizontal and vertical ±15° visual fields, the in-going and out-going wide-field individual myopic eye models were constructed to obtain the wavefront aberrations in the object and image spaces of the same eye over ±45° horizontal and vertical visual fields. The average differences in the mean sphere and astigmatism were below 0.25 D between the object and image spaces over the horizontal and vertical ±45° visual fields under 3 mm and 6 mm pupil diameter. The wavefront aberrations in the object space are a proper representation of the aberrations in the image space at least for horizontal visual fields ranging from -35°to +35° and vertical visual fields ranging from -15°to +15°.

7 March 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
Yongji LiuYongji Liu
Yongji Liu
DLDongyu Liu
Dongyu Liu
XHXiaoyang Hu
Xiaoyang Hu
XCXiaoqin Chen
Xiaoqin Chen
HLHongliang Liu
Hongliang Liu
LLLihua Li
Lihua Li
The mechanism by which myopia-managing spectacle lenses slow myopia progression remains controversial. Understanding the changes these lenses introduce to peripheral imaging properties helps shed light on this controversial issue. Given the difficulty of directly measuring these changes in clinical settings, this study combined experimental and modeling approaches to evaluate changes in images at the retina induced by myopia-managing lenses. Optical characteristics that may related to the efficacy of the lenses with concentric cylindrical annular refractive elements (CARE) in myopia control were investigated. Three lenses were evaluated: MyoCare (MC), MyoCare S (MCS), and a single vision (SV) lens with a custom-built physical eye model and optical simulations for the analysis. The simulated PSFs are consistent with the measured ones. PSF analysis showed that MC and MCS lenses produce discrete curves, resulting in remarkable distortion in the simulated retina images, especially for large eccentricities. Whether they increase or decrease contrast depends on the spatial frequencies and eccentricities. These lenses also increase retinal light intensity at different eccentricities. The positive power of the CARE structure introduces myopic defocus of less than 0.25 D at only a limited range of eccentricities. The proposed approaches present relatively straightforward techniques for evaluating the optical performance of myopia-managing spectacle lenses.

31 January 2023 in Optics
Verified
Journal Article
Open access
PDF file
KLKunqi Li
Kunqi Li
XCXiaoqin Chen
Xiaoqin Chen
YBYayan Bian
Yayan Bian
YXYuwei Xing
Yuwei Xing
XLXiaolan Li
Xiaolan Li
Yongji LiuYongji Liu
Yongji Liu
To obtain a continuous range of clear vision for pseudophakic eyes, a design of intraocular lens (IOL) with extended depth of focus (EDoF) was proposed. The IOL was optimized with a multi-configuration approach based on a pseudophakic eye model and the optical performances of the designed IOL were analyzed. The modulation transfer function (MTF) values remain above 0.2 at 50 lp/mm for object distance ranging from 0.35 m to infinity in both photopic vision and mesopic vision over a field of 4°. The optical performances remain stable when the pupil diameter changes from 2.25 mm to 5 mm. Besides, the presented theoretical analyses show the designed IOL has good optical performances for polychromatic light and corneal asphericity. The above shows that the IOL exhibits an excellent ability for pseudophakic eyes to see the object in a continuous range of distance.

24 May 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
YXYuwei Xing
Yuwei Xing
Yongji LiuYongji Liu
Yongji Liu
KLkq li
kq li
HSHui Song
Hui Song
MXMengchen Xu
Mengchen Xu
YWYan Wang
Yan Wang
This study presents the fabrication and evaluation of a sinusoidal extended depth-of-focus (EDoF) intraocular lens (IOL) based on our previously proposed design approach. The power, through-focus MTF, and surface profile were measured using commercial instruments. Through-focus images of a United States Air Force (USAF) 1951 resolution target formed by the fabricated IOL were compared with Symfony and AR40E under monochromatic and polychromatic light using optical bench testing. Simulations assessed visual acuity (VA) of a pseudophakic model eye with the EDoF IOL, including evaluation of tilt and decentration effects. Results indicate that the base power, add power, and the through-focus MTF@50 lp/mm of the fabricated IOL at a 3 mm pupil size align with the design specifications. The extended-depth-of-focus and imaging performance for the far vision of the fabricated IOL under both monochromatic and polychromatic light conditions at a 3.0 mm pupil diameter is comparable to that of Symfony. In addition, the fabricated IOL exhibits a similar extended-depth-of-focus for three discrete wavelengths. The pseudophakic model eye with the designed EDoF IOL demonstrates a VA exceeding 0.1 logMAR within a defocus range of 2.44 D. The VA is tolerant to both IOL tilt and decentration. These findings demonstrate the promising potential of the sinusoidal EDoF IOL design for future applications in cataract surgery.