Introduction: We aim to apply deep learning to achieve fully automated detection and classification of the Cervical Vertebrae Maturation (CVM) stages. We propose an innovative custom-designed deep Convolutional Neural Network (CNN) with a built-in set of novel directional filters that highlight the edges of the Cervical Vertebrae in X-ray images. Methods: A total of 1018 Cephalometric radiographs were labeled and classified according to the Cervical Vertebrae Maturation (CVM) stages. The images were cropped to extract the cervical vertebrae using an Aggregate Channel Features (ACF) object detector. The resulting images were used to train four different Deep Learning (DL) models: our proposed CNN, MobileNetV2, ResNet101, and Xception, together with a set of tunable directional edge enhancers. When using MobileNetV2, ResNet101 and Xception, data augmentation is adopted to allow adequate network complexity while avoiding overfitting. The performance of our CNN model was compared with that of MobileNetV2, ResNet101 and Xception with and without the use of directional filters. For validation and performance assessment, k-fold cross-validation, ROC curves, and p-values were used. Results: The proposed innovative model that uses a CNN preceded with a layer of tunable directional filters achieved a validation accuracy of 84.63%84.63% in CVM stage classification into five classes, exceeding the accuracy achieved with the other DL models investigated. MobileNetV2, ResNet101 and Xception used with directional filters attained accuracies of 78.54%, 74.10%, and 80.86%, respectively. The custom-designed CNN method also achieves 75.11% in six-class CVM stage classification. The effectiveness of the directional filters is reflected in the improved performance attained in the results. If the custom-designed CNN is used without the directional filters, the test accuracy decreases to 80.75%. In the Xception model without the directional filters, the testing accuracy drops slightly to 79.42% in the five-class CVM stage classification. Conclusion: The proposed model of a custom-designed CNN together with the tunable Directional Filters (CNNDF) is observed to provide higher accuracy than the commonly used pre-trained network models that we investigated in the fully automated determination of the CVM stages.
1 November 2016 in American Journal of Orthodontics and Dentofacial Orthopedics
Objective: This study aimed to evaluate the effectiveness of Dental Monitoring™ (DM™) Artificial Intelligence Driven Remote Monitoring Technology (AIDRM) technology in improving the patient's oral hygiene during orthodontic treatment through AI‐based personalized active notifications.Methods: A prospective clinical study was conducted on two groups of orthodontic patients. DM Group: (n = 24) monitored by DM weekly scans and received personalized notifications on the DM smartphone application regarding their oral hygiene status. Control Group (n = 25) not monitored by DM. Both groups were clinically assessed using Plaque Index (OPI) and the Modified Gingival Index (MGI). DM Group was followed for 13 months and the Control Group was followed for 5 months. Student‐independent t test and paired t tests were used to investigate the mean differences between study groups and between time points for each group respectively.Results: At all time points, the mean differences indicated that the DM group had lower OPI and MGI values than the control group. The mean value for OPI and MGI were statistically significantly lower in the DM group (OPI = 1.96, MGI = 1.56) than in the control group (OPI = 2.41, MGI = 2.17) after 5 months. A rapid increase in mean OPI and MGI values was found between T0 and T1 for both study groups. A plateau effect for OPI scores appeared to occur from T1 to T5 for both study groups, but the plateau effect seemed to be more pronounced for the DM group than the study group. The MGI values for both study groups also increased dramatically from baseline to T5, however, a plateau effect was not observed.Conclusions: The oral hygiene of orthodontic patients rapidly worsens over the first 3 months and plateaus after about 5 months of treatment. AIDRM by weekly DM scans and personalized active notifications may improve oral hygiene over time in orthodontic patients.
21 June 2023 in American Journal of Orthodontics and Dentofacial Orthopedics