Despite considerable benefits associated with current drug-eluting stents, continued attention to the safety, efficacy, and deliverability of available drug-eluting stent has led to the development of newer stent. This study was a single-centre, prospective, non-randomized, first-in-man study which included clinical follow-up data was collected at 1, 8 and 12 months after the procedure. The study included 105 patients with de novo native coronary artery lesions including multi-vessel disease treated with Supralimus-Core® stent. Repeat angiography was performed 8 months post-stent implantation. At quantitative coronary angiography 8-month luminal late loss was 0.39 ± 0.33 mm in-stent and 0.33 ± 0.35 mm in-segment. The incidence of any major adverse cardiac event at 30 days, 8 months and 12 months was 1 (1%), 6 (6%) and 7 (7%) respectively. This study demonstrates that the Supralimus-Core® SES is a safe and effective treatment for patients with obstructive coronary artery disease. ClinicalTrials.gov ID: NCT00811616.
Optical coherence tomography (OCT) is reported to be a feasible and safe imaging modality for the guidance of percutaneous coronary intervention (PCI) of complex lesions. This multicenter, prospective registry assessed the minimum stent area (MSA) achieved under OCT guidance. A performance goal of 24% improvement in MSA over and above the recommendation set by the European Association of Percutaneous Cardiovascular Interventions Consensus 2018 (4.5 mm2 MSA for non-left main and 3.5 mm2 for small vessels). The incidence of contrast-induced nephropathy was also assessed. Core lab analysis was conducted. Five hundred patients (average age: 59.4 ± 10.1 years; 83% males) with unstable angina (36.8%), NSTEMI (26.4%), and STEMI (22%) were enrolled. The primary endpoint was achieved in 93% of lesions with stent diameter ≥2.75 mm (average MSA: 6.44 mm2) and 87% of lesions with stent diameter ≤2.5 mm (average MSA: 4.56 mm2). The average MSA (with expansion ≥80% cutoff) was 6.63 mm2 and 4.74 mm2 with a stent diameter ≥2.75 mm and ≤2.5 mm, respectively. According to the core lab analysis, the average MSA achieved with a stent diameter ≥2.75 mm and ≤2.5 mm was 6.23 mm2 and 3.95 mm2, respectively (with expansion ≥80% cutoff). Clinically significant serum creatinine was noted in two patients (0.45%). Major adverse cardiac events at 1 year were noted in 1.2% (n = 6) of the patients; all were cardiac deaths. PCI under OCT guidance improves procedural and long-term clinical outcomes in patients with complex lesions not just in a controlled trial environment but also in routine clinical practice.
Pharmacokinetic Study of Sirolimus-Eluting BioResorbable Vascular Scaffold System for Treatment of De Novo Native Coronary Lesions: A Sub-Study of MeRes-1 Trial
This study aimed to assess the effectiveness of current lipid-lowering therapy in achieving low-density lipoprotein cholesterol (LDL-C) goals in Indian patients undergoing coronary revascularization. Consecutive subjects (n = 1275, mean age 60.0 +/- 9.7 years, 87.2 % men) with newly diagnosed coronary artery disease and undergoing coronary revascularization during the period 1 Jan 2023 to 31 Dec 2023 were included. After a median follow-up of 99 days (interquartile range 91-109 days), the mean LDL-C was 63.9 +/- 24.3 mg/dL with 67.5% and 29.9% of subjects having LDL-C <70 mg/dL and <50 mg/dL, respectively. These proportions were 70.8% and 32.1% for patients treated with high-intensity statin therapy (rosuvastatin 20-40 mg/d or atorvastatin 40-80 mg/d). Among patients treated with rosuvastatin 40 mg/d and ezetimibe 10 mg/d, 53.3% achieved LDL-C <50 mg/dL. These findings underscore the need for greater usage of combination lipid-lowering therapy and agents with high LDL-C lowering efficacy.
1 March 1996 in Catheterization and Cardiovascular Diagnosis