Alexander Christoph Paulus

Dr. Alexander Christoph Paulus

Department of Orthopaedic Surgery, University Hospital of Munich (LMU), Campus Großhadern, Marchioninistr. 15, D-81377 Munich, Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
APAlexander Christoph Paulus
Alexander Christoph Paulus
SHS. Haßelt
S. Haßelt
VJV. Jansson
V. Jansson
AGA. Giurea
A. Giurea
HNH. Neuhaus
H. Neuhaus
SUS. Utzschneider
S. Utzschneider
Introduction. Increasing interest developed in the use of carbon-fiber-reinforced-poly-ether-ether-ketones (CFR-PEEK) as an alternative bearing material in knee arthroplasty. The effects of CFR-PEEK wear inin vitroand animal studies are controversially discussed, as there are no data available concerning human tissue. The aim of this study was to analyze human tissue containing CFR-PEEK as well as UHMWPE wear debris. The authors hypothesized no difference between the used biomaterials.Methods and Materials. In 10 patients during knee revision surgery of a rotating-hinge-knee-implant-design, synovial tissue samples were achieved (tibial inserts: UHMWPE; bushings and flanges: CFR-PEEK). One additional patient received revision surgery without any PEEK components as a control. The tissue was paraffin-embedded, sliced into 2 μm thick sections, and stained with hematoxylin and eosin in a standard process. A modified panoptical staining was also done.Results. A “wear-type” reaction was seen in the testing and the control group. In all samples, the UHMWPE particles were scattered in the tissue or incorporated in giant cells. CFR-PEEK particles were seen as conglomerates and only could be found next to vessels. CFR-PEEK particles showed no giant-cell reactions. In conclusion, the hypothesis has to be rejected. UHMWPE and PEEK showed a different scatter-behavior in human synovial tissue.

3 July 2017 in Materials
Verified
Journal Article
Open access
PDF file
AJAnika Jonitz-Heincke
Anika Jonitz-Heincke
JTJenny Tillmann
Jenny Tillmann
AKAnnett Klinder
Annett Klinder
SKSimone Krueger
Simone Krueger
JKJ. Philippe Kretzer
J. Philippe Kretzer
RBRainer Bader
Rainer Bader
Osteolysis in the periprosthetic tissue can be caused by metallic wear particles and ions that can originate from implant surface corrosion. These products influence cellular behavior and stimulate the expression of proinflammatory cytokines. The purpose of this study was to evaluate the impact of CoCr29Mo6 ions on cell survival, differentiation, and cytokine expression in human osteoblasts and peripheral blood mononuclear cells (PBMCs). Thus, we exposed cells with a mixture of 200 µg/L ion solution and determined cell viability and apoptosis/necrosis. Gene expression analyses of osteoblastic and osteoclastic differentiation markers as well as pro-osteolytic mediators (IL-6, IL-8, TNF-α, MCP-1, MMP1, TIMP1) were performed. These markers were also investigated in mixed cultures of adherent and non-adherent PBMCs as well as in co-cultures of human osteoblasts and PBMCs. The ion solution induced necrosis in osteoblasts and PBMCs in single cultures. All examined mediators were highly expressed in the co-culture of osteoblasts and PBMCs whereas in the single cell cultures only IL-6, IL-8, and MMP1 were found to be stimulated. While the applied concentration of the CoCr29Mo6 ion solutions had only marginal effects on human osteoblasts and PBMCs alone, the co-culture may provide a comprehensive model to study osteolytic processes in response to Co and Cr ions.

4 July 2022 in Batteries & Supercaps
Verified
Journal Article
Open access
MCMarvin Cronau
Marvin Cronau
APAlexander Christoph Paulus
Alexander Christoph Paulus
LPLars Pateras Pescara
Lars Pateras Pescara
MKMoritz Kroll
Moritz Kroll
DRDiemo Renz
Diemo Renz
BRBernhard Roling
Bernhard Roling
Increasing the thickness of composite electrodes in lithium‐ion batteries from about 80–100 μm in state‐of‐the‐art commercial cells to several 100 μm would enhance the energy density, however at the expense of the power density. Despite this common knowledge, quantitative studies on the impedance and rate capability of composite electrode in dependence of the electrode thickness are scarce. Therefore, we have carried out a case study on LiCoO2 composite electrodes with thicknesses up to about 250 μm. We first demonstrate that conventional composite electrode preparation leads to ion transport tortuosities in the electrolyte‐filled pores, which are virtually independent of the thickness. The thickness‐dependent impedance of these electrodes decreases with increasing thickness and follows the predictions of a generalized transmission line (GTLM) model. We use the GTLM model for analyzing in what way cycling of ultrathick electrodes (250–300 μm) with a rate of 1 C should be achievable.

19 November 2013 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
APAlexander Christoph Paulus
Alexander Christoph Paulus
JFJ. Frenzel
J. Frenzel
AFA. Ficklscherer
A. Ficklscherer
BRB. P. Roßbach
B. P. Roßbach
CMC. Melcher
C. Melcher
SUS. Utzschneider
S. Utzschneider

26 February 2020 in Materials
Verified
Journal Article
Open access
PDF file
XCXiangyun Cheng
Xiangyun Cheng
SDSabine C. Dirmeier
Sabine C. Dirmeier
SHSandra Haßelt
Sandra Haßelt
ABAndrea Baur-Melnyk
Andrea Baur-Melnyk
JKJ. Philippe Kretzer
J. Philippe Kretzer
APAlexander Christoph Paulus
Alexander Christoph Paulus
Metal particles and ions released from implants not only have a fundamental effect on the longevity of total joint replacements, but can also be disseminated to remote organs. Periprosthetic tissues harvested during revision surgeries mainly reflect end-stage failure but may not adequately reveal initial biological reactions and systemic side effects. Therefore, primary reactions caused by metal particles and ions were investigated in an established murine model. Left knee joints in three groups, each consisting of ten female BALB/c mice, received injections of metal ions (MI), metal particles (MP) and phosphate-buffered saline (PBS) (control). Seven days after the injection, immunohistochemical analyses of the synovial layer were performed with respect to some biological markers including Tumor necrosis factor -α (TNF-α), Interleukin-6 (IL-6), Interleukin-1β (IL-1β), Cluster of Differentiation 45 (CD45), Cluster of Differentiation 68 (CD68) and Cluster of Differentiation 3(CD3). The MP group showed significantly enhanced proinflammatory cytokine expression (TNF-α, IL-6 and IL-1β) compared with the other groups (p < 0.05). Interestingly, CD3, as a marker for T lymphocytes, did not increase in any of the groups. The MI group showed a significantly increased expression of CD45 compared with the control group (p < 0.05). Therefore, during the primary process, metal particles have stronger pro-inflammatory potential than metal ions, and T lymphocytes did not seem to be activated in our murine model. Systemic reactions caused by metal particles and ions were found by observing the untreated right knees.

29 October 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
APAlexander Christoph Paulus
Alexander Christoph Paulus
KEKathrin Ebinger
Kathrin Ebinger
XCXiangyun Cheng
Xiangyun Cheng
SHSandra Haßelt
Sandra Haßelt
PWPatrick Weber
Patrick Weber
SUSandra Utzschneider
Sandra Utzschneider
Metal wear debris and released ions (CoCrMo), which are widely generated in metal-on-metal bearings of hip implants, are also found in patients with metal-on-polyethylene bearings due to the mechanically assisted crevice corrosion of modular taper junctions, including head-neck and neck-stem taper interfaces. The resulting adverse reactions to metal debris and metal ions frequently lead to early arthroplasty revision surgery. National guidelines have since been published where the blood metal ion concentration of patients must consistently be monitored after joint replacement to prevent serious complications from developing after surgery. However, to date, the effect of metal particles and metal ions on local biological reactions is complex and still not understood in detail; the present study sought to elucidate the complex mechanism of metal wear-associated inflammation reactions. The knee joints in 4 groups each consisting of 10 female BALB/c mice received injections with cobalt chrome ions, cobalt chrome particles, and ultra-high-molecular-weight polyethylene (UHMWPE) particles or PBS (control). Seven days after injection, the synovial microcirculation and knee joint diameter were assessed via intravital fluorescence microscopy followed by histological evaluation of the synovial layer. Enlarged knee diameter, enhanced leukocyte to endothelial cell interactions, and an increase in functional capillary density within cobalt chrome particle-treated animals were significantly greater than those in the other treatment groups. Subsequently, pseudotumor-like tissue formations were observed only in the synovial tissue layer of the cobalt chrome particle-treated animals. Therefore, these findings strongly suggest that the cobalt chrome particles and not metal ions are the cause for in vivo postsurgery implantation inflammation.