Due to the seriousness of the water shortage crisis over the past decades, the need to manage water use has become more and more important. Pressure management in urban water distribution networks is one of the options that can significantly reduce water loss. The pressure reducing valve (PRV) and the variable speed pump (VSP) are two devices that are most used in WDS pressure management. In the present study, an optimization code was first proposed to estimate the instantaneous water demand based on the reported network pressures. According to the estimated instantaneous water demand, another optimization code is presented based on the DE algorithm to control the installed PRVs and VSPs. This results in the uniform distribution of the pressure and reducing the excessive pressure on the water network for all hours of the day, reducing the water leakage and energy consumption accordingly. The provided method has been applied to a real water distribution network in northern Iran. The results showed that by applying this method, the network background leakage and the energy consumption have been reduced by 41.72% and 28.4%, respectively, compared to a non-management mode.
22 November 2017 in International Journal of Photoenergy
Nowadays, parabolic trough solar thermal plants are prevalent around the world. In different areas concerning the amount of solar radiation, their standard size is approximately between 20 and 100 MWe. Certainly, the right size of the solar field is the first selection with regard to nominal electrical power. A vast area will be economically unreasonable whereas a small area will mainly cause the power plant to operate at the part-load condition. This paper presents an economic modeling of a solar parabolic trough plant, operating at 25 MWe in Yazd, Iran. The varying types of collector dimensions have been investigated; then, by selecting autumnal equinox (22 September) at 12:00 PM as the design point, thermal performance of the solar power plant has been featured annually, in all conditions. The total operating time of the power plant is about 1726 hours (1248 hours in full-load condition). In the end, the effect of thermal storage tanks has been analyzed to save extra solar heat and use it at nights in hot months. By implementing a storage system, the total operating time will be increased to 3169 hours (2785 in full-load condition). Moreover, 7974 GJ useful thermal energy can be obtained from the solar field and storage system.
18 August 2023 in International Journal of Energy Research
The blade number and airfoil profile effects on the blade shape of a small horizontal-axis wind turbine (SHWT) were investigated. For this purpose, the NACA4412, SG6042, and SG6043 airfoils, as well as 2, 3, and 4 blades, were considered. Then, two optimization processes were used: first, the blades were designed to maximize the power coefficient (), and then a multiobjective optimization that included both maximizing and maximizing the starting torque () was employed. The differential evolution (DE) algorithm was employed to perform the optimization, and the blade element momentum aerodynamic approach was used to conduct the relevant computations. Also, to ensure the performance of the optimal blades, the computational fluid dynamics method was employed as well. The findings revealed that regardless of the number of blades and the type of airfoil, raising the twist angle () and chord length () along the radial direction of the blade, especially at the root part, helps increase the . It was observed that increasing the number of blades does not have a significant effect on the distribution of the selected airfoils, but the of the blades fitted with all three airfoils decreases. Regardless of the number of blades, while the geometry of blades utilizing the NACA4412 and SG6042 airfoils are close to each other, the blade with the SG6043 airfoil has the shortest , which reduces the generated of blades fitted with this airfoil. The results also establish that by increasing the number of blades from 2 to 3, the power coefficient () of the blades fitted with all three airfoils increases, but by further increasing the number of blades from 3 to 4, the change in completely depends on the airfoil profile.
This paper aims to explore the impact of the order of numerical schemes on the simulation of two-phase slug flow with a two-fluid model initiation. The governing equations of the two-fluid model have been solved by a class of Riemann solver. The numerical schemes applied in this paper involve first-order (Lax-Friedrichs and Rusanov), second-order (Ritchmyer), and high-order (flux-corrected transport or FCT and total variance diminishing or TVD). The results suggest that the TVD and FCT are able to predict the slug initiation with high accuracy compared with experimental results. Lax-Friedrichs and Rusanov are both first-order schemes and have second-order truncation error. This second-order truncation error caused numerical diffusion in the solution field and could not predict the slug initiation with high accuracy in contrast to TVD and FCT schemes. Ritchmyer is a second-order scheme and has third-order truncation error. This third-order truncation error caused dispersive results in the solution field and was not a proper scheme.
24 February 2026 in Biochemical Engineering Journal
This research investigates the effect of blade density and elevation above sea level on the startup time (Ts) and power coefficient (Cp) of a 1-kW two-bladed wind turbine. The study uses three Iranian hardwoods as the blade material and four counties of Iran with low wind speeds and different elevations as the case studies. The BW-3 airfoil is considered as the blade profile. A multi-objective optimization process with the aid of the differential evolution (DE) algorithm is utilized to specify the chord length and twist angle. The findings demonstrate that, while the maximum Cp of the optimal blades designed with all three types of wood is high and equal to 0.48, the average Ts of the optimal blades designed with oak and hornbeam wood is 84% and 108% higher than that of alder wood, respectively. It is also observed that, while raising the elevation to 2250 m decreases the Cp by only 2.5%, the ideal blade designed to work at sea level could not manage to start rotating at a height of 1607 m and above. Finally, an improvement in the Ts and Cp was observed by performing optimization based on the local atmospheric conditions associated with the incrementing blade chord length at high elevations.