View All Publications
9 August 2021 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
RSRuediger Schmid
Ruediger Schmid
ABAndreas F. Borkenstein
Andreas F. Borkenstein

6 October 2021 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
ABAndreas F. Borkenstein
Andreas F. Borkenstein
EBEva-Maria Borkenstein
Eva-Maria Borkenstein
BMBoris Malyugin
Boris Malyugin
Ophthalmic viscoelastic devices (OVDs) are currently used in cataract surgery and have significantly improved the safety and effectiveness of this surgical procedure. OVDs are classified according to the zero-shear viscosity and the cohesion-dispersion index in cohesive, dispersive, and viscoadaptives. OVDs create and maintain anterior chamber depth and visibility, protecting the corneal endothelium and other intraocular tissues during surgery. The selection of the most adequate OVD is especially relevant when performing cataract surgery in challenging cases, such as in hard, mature cataracts, flat anterior chamber, pseudoexfoliation syndrome, intraoperative floppy iris syndrome, or glaucoma surgery. In such cases, OVD is crucial for facilitating the surgical procedure and the associated minimal complication rate. The use of a combination of OVDs (soft-shell technique and modifications), the use of blue-colored OVDs, and the combination of sodium hyaluronate with lidocaine have also been described as useful tools in some of these challenging cases.

13 September 2022 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
RSRuediger Schmid
Ruediger Schmid
CFChristin Fuchs
Christin Fuchs
HLHolger Luedtke
Holger Luedtke
ABAndreas F. Borkenstein
Andreas F. Borkenstein
Purpose: To assess the depth of focus of four latest non-diffractive extended range of vision IOLs on the optical bench. Such comparison had not been done before. Methods: We assessed and compared the through focus modulation transfer function (MTF) of the following novel IOLs with a nominal power of 22 D: Acrysof Vivity, LuxSmart Crystal, RayOne EMV and Tecnis Eyhance. An ISO-2 model eye was applied with apertures of 3 and 4.5 mm with monochromatic light of 546 nm. Measurements were done on OptiSpheric IOL PRO 2 optical bench. Results: For the aperture of 3 mm, Eyhance and RayOne EMV showed the most pronounced peak in MTF with only little enlarged depth of power. Vivity and LuxSmart showed two peaks of about 1.7 D respectively 1.3 D depth of focus, yet reduced MTF and with maxima differently located. For 4.5 mm, MTF values for Eyhance and particularly for RayOne EMV dropped. For Vivity and LuxSmart, only the peak for the secondary focus decreased. Conclusion: Vivity and LuxSmart showed a larger depth of focus for our measuring conditions than Eyhance and RayOne EMV. Correspondingly, the peak MTF was best for Eyhance and RayOne ERV with small aperture. With the larger aperture, RayOne EMV considerably lost performance.

27 September 2021 in Biomedicine Hub
Verified
Journal Article
Open access
PDF file
ABAndreas F. Borkenstein
Andreas F. Borkenstein
EBEva-Maria Borkenstein
Eva-Maria Borkenstein
HLHolger Luedtke
Holger Luedtke
RSRuediger Schmid
Ruediger Schmid
Background: The aim of the study was to analyze the objective optical properties of 2 enhanced depth of focus (EDoF) intraocular lenses (IOLs) using optical bench analysis. Methods: This experimental study investigates 2 new EDoF IOLs, the Alcon AcrySof IQ Vivity and the Bausch & Lomb LuxSmart Crystal, on the optical bench, using OptiSpheric IOL PRO2 (Trioptics, Germany) in order to assess the optical quality according to ISO 11979 with ISO-2 Cornea. IOLs (power 22.0 D) were evaluated regarding modulation transfer function (MTF) at 50 lp/mm and Strehl ratio (SR) using a 3.0-mm and a 4.5-mm aperture. In addition, wavefront measurements were obtained using WaveMaster® IOL 2 device (Trioptics, Germany), and USAF targets were analyzed. Results: Centered: the MTF (mean) at 50 lp/mm (AcrySof IQ Vivity/LuxSmart Crystal) with 3.0 mm aperture was 0.250/0.257 and with 4.5 mm aperture 0.202/0.243. The SR (mean) with 3.0 mm aperture was 0.261/0.355 and with 4.5 mm aperture 0.176/0.206. Decentered by 1 mm: the MTF (mean) at 50 lp/mm (AcrySof IQ Vivity/LuxSmart Crystal) with 3.0 mm aperture was 0.266/0.247 and with 4.5 mm aperture 0.126/0.215. The SR (mean) with 3.0 mm aperture was 0.272/0.234 and with 4.5 mm aperture 0.133/0.183. Tilted by 5 degree: the MTF (mean) at 50 lp/mm (AcrySof IQ Vivity/LuxSmart Crystal) with 3.0 mm aperture was 0.221/0.360 and with 4.5 mm aperture 0.214/0.229. The SR (mean) with 3.0 mm aperture was 0.232/0.428 and with 4.5 mm aperture 0.225/0.229. The simulated visual function using USAF test targets showed corresponding qualitative results. Wavefront measurements proved a complex optical design. Higher order aberrations in the central part of the optics were modulated up to the 10th order to enhance the range of functional vision to near distance, leaving the peripheral parts of the optics aberration free or as aberration correcting. Conclusion: The diversity of EDOF IOLs, their optics, and their respective impact on the vision quality must be understood in order to select the appropriate IOL in each individual case. This analysis of new, innovative IOL optics based on increased negative spherical aberration may help the ophthalmic surgeon to select the IOL which meets the individual requirements of the patient for best postoperative outcomes. It seems that there is no perfect IOL that is equally suitable for all patients, but the right choice is an individual, customized approach dealing with patients’ expectations.

26 September 2022 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
RSRuediger Schmid
Ruediger Schmid
HLHolger Luedtke
Holger Luedtke
ABAndreas F. Borkenstein
Andreas F. Borkenstein
Purpose: To analyze the effect of decentration and tilt on four novel non diffractive extended range of vision intraocular lenses (IOLs). Methods: Acrysof Vivity, LuxSmart Crystal, RayOne EMV and Tecnis Eyhance were compared on the optical bench (power of 22 D each). Modulation transfer functions were obtained and Strehl ratio was calculated in an ISO-2 model. Apertures of 3 mm and 4.5 mm were applied. For qualitative assessment, United States Airforce (USAF) chart images were evaluated. Additional to centered IOLs, tilt of 5 degrees and decentration of 1 mm were applied. Results: RayOne EMV was very robust against misalignment but had considerable deterioration of modulation transfer function (MTF) for large aperture with USAF images seriously blurred. Tilt and decentration decreased the performance of Eyhance significantly but had minor impact on the performance of Vivity and LuxSmart. For 4.5 mm aperture, MTF and Strehl ratio decreased markedly for all IOLs compared to 3 mm aperture size. The best MTF and Strehl ratio was obtained for Eyhance IOL well centered for both sizes of aperture. Conclusion: Tilt and decentration had a major impact on the performance of Eyhance only, which performed best of all IOLs tested when well centered. With large aperture, performance of all IOLs significantly decreased. Manufacturer's different approaches for these novel IOLs to increase depth of focus by increasing spherical aberration lead to a different performance in respect to contrast function and sensitivity to misalignment. Our results apply to the distance vision. Near vision performance will be evaluated in a separate investigation.

5 February 2022 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
ABAndreas F. Borkenstein
Andreas F. Borkenstein
EBEva-Maria Borkenstein
Eva-Maria Borkenstein
Introduction Characteristics of the haptics and optic–haptic junction (OHJ) of an intraocular lens (IOL) affect IOL position in the capsular bag, positional stability, and the development of posterior capsule opacification. Therefore, the haptics and OHJ have a role in determining initial and long-term visual outcomes after cataract surgery. Understanding differences in the haptics and OHJ of available IOLs and in the relationships between the haptics of each IOL and the capsular bag across a range of capsular bag sizes might inform selection of an IOL model for individuals. Purpose To evaluate the geometry of five currently marketed, commonly used one-piece hydrophobic acrylic monofocal IOLs and changes in haptic–capsular bag relationships according to capsular bag size using a range of compression well diameters. Methods AcrySof SN60WF, CT LUCIA 621PY, enVista MX60, TECNIS ZCB00, and Vivinex XY1 IOLs were scanned with computed tomography (CT) in a dry, uncompressed state for quantitative analyses of haptic and OHJ dimensions and qualitative assessment of geometry. CT scanning was done after IOL placement into a series of compression wells (11.5, 11.0, 10.0, and 9.0 mm) for analyses of haptic angle of contact (AoC) and capsular bag contact (CBC). IOL axial alignment and haptic–capsular bag relationships were assessed on side-view and 3-dimensional top-view images, respectively. Results The qualitative and quantitative evaluations highlighted differences in haptic and OHJ geometry and dimensions across the five IOLs. All haptic dimensions (length, thickness, surface area, volume) and all OHJ dimensions (surface area and volume) were greatest for the CT LUCIA 621PY IOL. Compared to the IOL that had the smallest measurement for each parameter, the value for the CT LUCIA 621PY IOL was 31–91% larger. The lens with the largest OHJ surface area and volume showed values that were 500% and 240% greater than the corresponding values for the lens with the smallest OHJ surface area and OHJ volume. The AoC and CBC values decreased with increasing well size for all IOLs. The CT LUCIA 621PY had the greatest AoC and CBC values for all well sizes and the smallest percentage change in AoC and CBC comparing the values from the 9.0 mm and 11.5 mm wells. Conclusion The in vitro evaluations in this study highlight differences in the haptic and OHJ geometric characteristics of the five IOLs studied. The collected evidence refutes opinions that all hydrophobic acrylic one-piece IOLs are the same and supports the idea that individual IOLs can have relative advantages and disadvantages that depend on the individual case. We believe the knowledge of geometry is necessary for the surgeon to have the opportunity to select the best “customized” option in the individual case as a result of anatomical conditions and secondary diagnoses. Our bench study shows how big the differences are in currently available monofocal hydrophobic acrylic lenses.