Matthias Roediger

Prof. Dr. Matthias Roediger


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MRMatthias Roediger
Matthias Roediger
LSLea Schneider
Lea Schneider
SRSven Rinke
Sven Rinke
This study evaluated the marginal accuracy of CAD/CAM-fabricated crown copings from four different materials within the same processing route. Twenty stone replicas of a metallic master die (prepared upper premolar) were scanned and divided into two groups. Group 1 (n=10) was used for a pilot test to determine the design parameters for best marginal accuracy. Group 2 (n=10) was used to fabricate 10 specimens from the following materials with one identical CAD/CAM system (GAMMA 202, Wissner GmbH, Goettingen, Germany): A = commercially pure (cp) titanium, B = cobalt-chromium alloy, C = yttria-stabilized zirconia (YSZ), and D = leucite-reinforced glass-ceramics. Copings from group 2 were evaluated for the mean marginal gap size (MeanMG) and average maximum marginal gap size (AMaxMG) with a light microscope in the “as-machined” state. The effect of the material on the marginal accuracy was analyzed by multiple pairwise comparisons (Mann–Whitney, U-test, α=0.05, adjusted by Bonferroni-Holmes method). MeanMG values were as follows: A: 46.92 ± 23.12 μm, B: 48.37 ± 29.72 μm, C: 68.25 ± 28.54 μm, and D: 58.73 ± 21.15 μm. The differences in the MeanMG values proved to be significant for groups A/C (p=0.0024), A/D (p=0.008), and B/C (p=0.0332). AMaxMG values (A: 91.54 ± 23.39 μm, B: 96.86 ± 24.19 μm, C: 120.66 ± 32.75 μm, and D: 100.22 ± 10.83 μm) revealed no significant differences. The material had a significant impact on the marginal accuracy of CAD/CAM-fabricated copings.

23 March 2010
Verified
Journal Article
Closed access
MRMatthias Roediger
Matthias Roediger
NGNikolaus Gersdorff
Nikolaus Gersdorff
AHAlfons Huels
Alfons Huels
SRSven Rinke
Sven Rinke

1 January 2015 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
SRSven Rinke
Sven Rinke
HRHajo Rasing
Hajo Rasing
NGNikolaus Gersdorff
Nikolaus Gersdorff
RBRalf Buergers
Ralf Buergers
MRMatthias Roediger
Matthias Roediger
Rinke S, et al. J Adv Prosthodont. 2015 Aug;7(4):338-343. http://dx.doi.org/10.4047/jap.2015.7.4.338

1 January 2015 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
SRSven Rinke
Sven Rinke
RBRalf Buergers
Ralf Buergers
DZDirk Ziebolz
Dirk Ziebolz
MRMatthias Roediger
Matthias Roediger
Rinke S, et al. J Adv Prosthodont. 2015 Aug;7(4):329-337. http://dx.doi.org/10.4047/jap.2015.7.4.329

1 November 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MRMatthias Roediger
Matthias Roediger
JKJanine Kloß
Janine Kloß
NGNikolaus Gersdorff
Nikolaus Gersdorff
RBRalf Bürgers
Ralf Bürgers
SRSven Rinke
Sven Rinke

31 October 2018 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
SRSven Rinke
Sven Rinke
LSLea Schneider
Lea Schneider
XSXenia Schulz
Xenia Schulz
VWVicky Wiedemann
Vicky Wiedemann
RBRalf Bürgers
Ralf Bürgers
MRMatthias Roediger
Matthias Roediger