The ongoing pandemic due to novel coronavirus disease-2019 (COVID-19) has rapidly unsettled the health sector with a considerable fatality rate. The main factors that help minimize the spread of this deadly virus are the proper use of masks, social distancing and antibody growth rate in a person. Based on these factors, we propose a new nature-inspired meta-heuristic algorithm named COVID-19 Based Optimization Algorithm (C-19BOA). The proposed C-19BOA mimics the spread and control behavior of coronavirus disease centered on three containment factors: (1) social distancing, (2) use of masks, and (3) antibody rate. Initially, the mathematical models of containment factors are presented, and further, the proposed C-19BOA is developed. To ascertain the effectiveness of the developed C-19BOA, its performance is verified on standard IEEE mathematical benchmark functions for the minimization of these benchmark functions and convergence to the optimal values. These performances are compared with established bio-inspired optimization algorithms available in the literature. Finally, the developed C-19BOA is applied on an electrical power system load–frequency–control model to test its effectiveness in optimizing the power system parameters and to check its applicability in solving modern engineering problems. A performance comparison of the proposed C-19BOA and other optimization algorithms is validated based on optimizing the controller gains for reducing the steady-state errors by comparing the effective frequency and tie-line power regulation ability of an industrially applied Proportional–Integral–Derivative controller (PID) and Active Disturbance Rejection controller (ADRC). Moreover, the robustness of C-19BOA optimized PID and ADRC gains is tested by varying the system parameters from their nominal values.
25 November 2021 in Optimal Control Applications and Methods
The present paper proposes a novel disturbance rejection-based scheme applied to a power system for concurrent control of system voltage, frequency, and tie-line power. The generating units in the power system comprise varied generating sources, such as thermal, diesel, solar-thermal, and wind sources. Owing to the present rigid limitations on energy assets and environmental alarms, electric vehicles are integrated with the power system in both areas. The complex power system needs a robust controller for stable operation. In response to this challenge, a novel second-order Active Disturbance-Rejection-Control (ADRC) is modeled as a secondary controller for performance studies. An extended state observer is designed for the estimation of system disturbance and uncertainties assisting ADRC in compensating for the impact through disturbance rejection. The magnetotactic bacteria-optimization approach is utilized to optimize the controller gains by reducing the errors in the objective function. Detailed case studies are carried out on two-area and three-area hybrid power-system incorporating different renewable energy plants to test the performance of the proposed controller. The dominance of the developed second-order-ADRC is verified based on system performance improvement concerning testified controllers available in the literature. The developed second-order-ADRC validates the robustness under different system-changed conditions. The fact that electric vehicles assist in system dynamic regulation is studied thoroughly.