The present work is concerned with an experimental study of the hydrodynamic damping provided by using vertical baffles in partially filled rectangular tanks. The damping ratio is evaluated for different vertical baffle dimensions, shapes, numbers, and arrangements. A small-scale test rig consisting of a partially filled rectangular tank with a pendulum suspension is designed and constructed to measure the transient responses of the system. The baffles are fitted to attenuate the lateral motion of the liquid slosh. Lower mounted and upper mounted vertical baffles of different heights and numbers are tested. Lower mounted vertical baffles with holes of different sizes and numbers are considered. Finally, the effect of a combination between upper, lower, and holed vertical baffles on the system damping is investigated. The results show that the size and location of the vertical baffles significantly influence the hydrodynamic damping. In general, the damping ratio increases as the tip of the lower mounted baffle plate is close to the liquid free surface and the location of the plate is close to the centre of the tank. Increasing the baffle numbers increases the damping ratio. The upper mounted vertical baffles are more suitable for a chargeable tank. The twin side upper mounted baffles and centre-holed lower mounted baffle arrangements give a maximum damping ratio.
Wind Farms are the viable solution for delivering clean energy in near future. There are many difficulties in ensuring higher quality power into the grid, as demanded by the more and more stringent grid codes. The solution of these problems could be solved by Flexible Alternate Current Transmission Systems (FACTS) devices in the system and particularly the Statatic synchronous condenser (STATCOM). Which uses the principle reactive power (injection or absorption).One of the main causes of disconnection of wind network is the variation of voltage (drop voltage or over voltage) at the bus bar connection. The use of STATCOM, allows regulating the voltage and maintaining the grid connected wind even under certain severe conditions of disturbance.In this paper, we propose a study of the importance use of STATCOM when it installed in a wind farm and we will try to see the effect of injecting reactive power in order to maintain the voltage at the nominal value. This opportunity offers the possibility of connecting the wind farm to the grid. The choice of this study is justified by simulation in MATLAB
The objective of this work was to analyze the behavior of good conducting granules in a newly designed plate-type electrostatic separator. Commercial software was employed for the numerical analysis of the electric field generated by an original electrode configuration. This enabled the evaluation of the electric charge and forces on conducting particles. The trajectory of a single particle was calculated over a set of 1300 points. The simulated results show that the trajectories depend on the applied voltage, the radius, and the mass density of the granules. They were found in good agreement with the experiments carried out on a laboratory electrostatic separator.
Vibrations generated during the operations of machine tools, especially at high-speed operation impact several issues in machined parts such as imprecision dimensions and a poor surface finish. This prompts research and studies into alternative materials for machine tool structures to provide considerable damping performance and acceptable stiffness compared to traditional materials. This paper deals with the experimental study of a developed granite-epoxy composite, made from waste granite and local epoxy as an alternative material for machine tool structures. A waste of Egyptian Red Aswan granite was used as filler after being crushed and sifted into three sizes: fine (less than 1 mm), medium (1 to 5 mm), and coarse (5 to 8 mm). A local commercial epoxy resin kemapoxy 150 was added to a granite aggregate mixture having grain proportions 50:25:25 for fine, medium, and large, respectively. The influence of the variation of the epoxy weight ratio on the static and damping characteristics of a proposed granite–epoxy composite material was experimentally investigated. To ensure a coherent granite-epoxy composite, the required minimum resin content of 13.88 wt% was determined, and the granite/epoxy ratios were selected as 85:15 wt%, 80:20 wt%, and 75:25 wt%. The findings exhibit that the largest compressive strength of 76.8 MPa and the greatest flexural strength of 35.4 MPa is achieved at the highest epoxy weight ratio of 25%. The largest damping ratio of 0.0202 is observed at the epoxy ratio of 20% and it decreases to 0.015 when the epoxy ratio is increased to 25%. An Egyptian granite-epoxy composite, made from waste granite and local epoxy, is a promising alternative material for machine tool structures. It offers both economic and environmental benefits, along with high mechanical and damping properties compared to traditional machine tool materials.
1 April 2018 in The International Conference on Applied Mechanics and Mechanical Engineering
This work deals with the reduction of vibration levels for rolling systems such asropeway gondola, cranes and ships using a dynamic vibration absorber (DVA). Theoptimum values of the DVA damping factor and the spring constant are determinednumerically through minimizing a maximum response of the main system. SingleDVA (SDVA) and multi- masses DVA (MDVA) in parallel configurations areexamined. A Mini-max criterion optimization method is utilized to calculate theoptimum design parameters of the DVA for many numbers of DVA masses with aconstant total mass. The results obtained that the rising of the mass ratio leads todecrease the vibration levels. Using the MDVA leads to enhanced robustness andvibration attenuation in the main system at the expense of growing the vibration inthe absorber. MDVA compared with SDVA have some advantages such as lowerfrequency ratios and low fatigue.
16 May 2019 in SAE International Journal of Advances and Current Practices in Mobility
The main intention of the present study is to reduce unwanted vibrations of mechanical systems through a sealed tuned liquid column damper (STLCD). A nonlinear mathematical model including nonlinear hydrodynamic damping and air stiffness of the STLCD is considered to study the dynamic behaviour of a structure-STLCD system. A parametric study to investigate the effect of the main parameters of the STLCD such as length ratio and mass ratio on the dynamic behaviour of the main system is presented. The air volume at rest is considered as an additional design parameter. The results obtained showed that the efficiency and the range of application of the STLCD to control the system’s resonance vibration are more than that of the traditional one. In addition, it can be noticed that the gain in vibration mitigation from the STLCD with increase in mass ratio and length ratio higher than 7% and 0.8, respectively, is generally modest. These results enhance the actual implementation of the STLCD for small horizontal space applications. Equations for the optimum value of the initial air height ratio and its corresponding performance index as a function of both mass ratio and relative length were proposed.