This work from first-principles insight uses a MoS2-WS2 in-plane heterostructure as a potential sensing material for detection of CO and C2H2, two typical dissolved gases in oil-immersed transformers, in order to evaluate the operation status. The adsorption performance of the MoS2-WS2 heterostructure upon two gas species is assessed via three adsorption sites and compared with isolated MoS2 and WS2. Results indicate that MoS2-WS2 performs with a much stronger binding force and charge-transfer for adsorptions of CO and C2H2 in comparison to the isolated counterpart, which gives rise to more obvious deformation in the electronic property of MoS2-WS2 as well as a much larger resistance-based sensing response. The recovery time of MoS2-WS2 for desorption of CO and C2H2 molecules is also appropriate to allow the reusability of such a sensor. The findings in this work uncover the admirable sensing potential of transition metal dichalcogenides (TMDs)-based heterostructures upon oil dissolved gases, which opens up a new way to explore novel 2D nanomaterials as resistive gas sensors for dissolved gas analysis in electrical oil-immersed transformers.
Partial discharge (PD) ultrasonic detection is an early sign of the insolation defects of power transformers. The early diagnosis of PD requires the high sensitivity and reliability of ultrasonic sensing systems. For this purpose, a reformative PD ultrasonic sensing system based on phase-shifted FBG (PS-FBG) was demonstrated. By using PS-FBG as the ultrasonic sensing unit, the ultrasonic sensing system improved the response to the ultrasonic signal and overcame the electromagnetic noise. To compensate for the influence of temperature change on the ultrasonic sensing system, an automatic wavelength scanning demodulating method was carried out. The wavelength spanning strategy was optimized based on the principle of cross-correlation, in order to quicken the spanning. A PD detection test in the transformer oil was conducted, and the result shows that PS-FBG was 17.5 times more sensitive than PZT. Because of the better ultrasonic response, the proposed system was able to achieve the early diagnosis of insolation faults in a power transformer.
The short-circuit tolerance capability of a transformer is a key performance indicator for ensuring the safe and stable operation of the power system. As the core component of the transformer, the mechanical stability of the windings under the huge electromagnetic force generated by the short-circuit current directly determines the short-circuit tolerance capability of the transformer. Most current research focuses on the coupling analysis of electromagnetic fields and structural fields, while ignoring the influence of temperature, a crucial variable, on the mechanical properties of the winding materials. Therefore, this study conducted tests on the transformer winding conductors, insulating materials, and silicon steel sheet materials under different temperatures, and provided a mathematical model and variation rules of elastic modulus with temperature and the B-H curves of silicon steel sheets at different temperatures. Based on this, a calculation method considering the short-circuit force of the transformer winding under different temperatures of the transformer components was proposed. This method enables precise calculations of the transformer’s mechanics under different temperatures and shows the distribution of leakage magnetic field, short-circuit force, and displacement of the winding under different transformer component temperatures. Finally, the Random Forest algorithm was used to estimate the short-circuit displacement of the transformer winding under different transformer component temperatures, and a short-circuit displacement prediction model based on temperature and impact frequency was provided. This offers a new method for evaluating the short-circuit capacity of the transformer. The feasibility of the calculation method was verified using a 750 kV transformer.
The short-circuit withstanding capability of a transformer is a critical indicator for evaluating its operational reliability. This study investigates the influence of the low-voltage winding height, a key structural parameter, on the electromagnetic forces induced by short-circuit currents and the resultant short-circuit withstand capability. First, theoretical calculation formulas for the transformer leakage magnetic field and winding electromagnetic forces were derived, establishing a foundation for subsequent analysis. Subsequently, two 110 kV transformers, identical in all structural parameters except for their low-voltage winding heights, were selected as case studies. Three-dimensional finite element models were constructed to perform detailed simulations and a comparative analysis of the leakage magnetic field distribution and electromagnetic forces under short-circuit conditions. Finally, practical short-circuit tests were conducted on both transformers for experimental validation, monitoring and comparison of their short-circuit reactance variation curves. Furthermore, a CNN-LSTM model, utilizing the winding axial height of a 110 kV three-phase three-limb transformer as the characteristic parameter, is developed to detect short-circuit fault damage in such transformers with varying winding heights. Through a combined approach of theoretical analysis, simulation, and experimental verification, this study confirms that the low-voltage winding height was a crucial factor affecting the transformer’s short-circuit withstand capability of the transformer. Studies have shown that with the increase in the height of low-voltage windings, the leakage magnetic flux of the low-voltage windings increases by 36%, the radial electromagnetic force increases by 37.5%, and the axial electromagnetic force increases by 8.5%. Excessively tall windings amplify radial electromagnetic forces, compromising mechanical stability and consequently increasing the risk of damage during short-circuit faults.