Edina Gyukity-Sebestyén

Dr. Edina Gyukity-Sebestyén

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2021 in Cancer and Metastasis Reviews
Verified
Journal Article
Open access
PDF file
MHMária Harmati
Mária Harmati
MBMátyás Bukva
Mátyás Bukva
TBTímea Böröczky
Tímea Böröczky
KBKrisztina Buzás
Krisztina Buzás
EGEdina Gyukity-Sebestyén
Edina Gyukity-Sebestyén
Metabolomic reprogramming in tumor and stroma cells is a hallmark of cancer but understanding its effects on the metabolite composition and function of tumor-derived extracellular vesicles (EVs) is still in its infancy. EVs are membrane-bound sacs with a complex molecular composition secreted by all living cells. They are key mediators of intercellular communication both in normal and pathological conditions and play a crucial role in tumor development. Although lipids are major components of EVs, most of the EV cargo studies have targeted proteins and nucleic acids. The potential of the EV metabolome as a source for biomarker discovery has gained recognition recently, but knowledge on the biological activity of tumor EV metabolites still remains limited. Therefore, we aimed (i) to compile the list of metabolites identified in tumor EVs isolated from either clinical specimens or in vitro samples and (ii) describe their role in tumor progression through literature search and pathway analysis.

Verified
Journal Article
Open access
PDF file
GDGabriella Dobra
Gabriella Dobra
MBMátyás Bukva
Mátyás Bukva
ZSZoltan Szabo
Zoltan Szabo
BBBella Bruszel
Bella Bruszel
MHMaria Harmati
Maria Harmati
KBKrisztina Buzas
Krisztina Buzas
Liquid biopsy-based methods to test biomarkers (e.g., serum proteins and extracellular vesicles) may help to monitor brain tumors. In this proteomics-based study, we aimed to identify a characteristic protein fingerprint associated with central nervous system (CNS) tumors. Overall, 96 human serum samples were obtained from four patient groups, namely glioblastoma multiforme (GBM), non-small-cell lung cancer brain metastasis (BM), meningioma (M) and lumbar disc hernia patients (CTRL). After the isolation and characterization of small extracellular vesicles (sEVs) by nanoparticle tracking analysis (NTA) and atomic force microscopy (AFM), liquid chromatography -mass spectrometry (LC-MS) was performed on two different sample types (whole serum and serum sEVs). Statistical analyses (ratio, Cohen’s d, receiver operating characteristic; ROC) were carried out to compare patient groups. To recognize differences between the two sample types, pairwise comparisons (Welch’s test) and ingenuity pathway analysis (IPA) were performed. According to our knowledge, this is the first study that compares the proteome of whole serum and serum-derived sEVs. From the 311 proteins identified, 10 whole serum proteins and 17 sEV proteins showed the highest intergroup differences. Sixty-five proteins were significantly enriched in sEV samples, while 129 proteins were significantly depleted compared to whole serum. Based on principal component analysis (PCA) analyses, sEVs are more suitable to discriminate between the patient groups. Our results support that sEVs have greater potential to monitor CNS tumors, than whole serum.

1 March 2017 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
AZAdam Zsedenyi
Adam Zsedenyi
BFBalazs Farkas
Balazs Farkas
GAGaser N. Abdelrasoul
Gaser N. Abdelrasoul
IRIlaria Romano
Ilaria Romano
EGEdina Gyukity-Sebestyén
Edina Gyukity-Sebestyén
KBKrisztina Buzas
Krisztina Buzas

9 September 2022 in medRxiv
Verified
Preprint
Open access
PDF file
VPVilja Pietiäinen
Vilja Pietiäinen
MPMinttu Polso
Minttu Polso
EMEde Migh
Ede Migh
CGChristian Guckelsberger
Christian Guckelsberger
MHMaria Harmati
Maria Harmati
JHJussi Hepojoki
Jussi Hepojoki
Here, we describe a scalable and automated, high-content microscopy -based mini-immunofluorescence assay (mini-IFA) for serological testing i.e., detection of antibodies. Unlike conventional IFA, which often relies on the use of cells infected with the target pathogen, our assay employs transfected cells expressing individual viral antigens. The assay builds on a custom neural network-based image analysis pipeline for the automated and multiplexed detection of immunoglobulins (IgG, IgA, and IgM) in patient samples. As a proof-of-concept, we employed high-throughput equipment to set up the assay for measuring antibody response against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection with spike (S), membrane (M), and nucleo (N) proteins, and the receptor-binding domain (R) as the antigens. We compared the automated mini-IFA results from hundreds of patient samples to the visual observations of human experts and to the results obtained with conventional ELISA. The comparisons demonstrated a high correlation to both, suggesting high sensitivity and specificity of the mini-IFA. By testing pre-pandemic samples and those collected from patients with RT-PCR confirmed SARS-CoV-2 infection, we found mini-IFA to be most suitable for IgG and IgA detection. The results demonstrated N and S proteins as the ideal antigens, and the use of these antigens can serve to distinguish between vaccinated and infected individuals. The assay principle described enables detection of antibodies against practically any pathogen, and none of the assay steps require high biosafety level environment. The simultaneous detection of multiple Ig classes allows for distinguishing between recent and past infection. Public The manuscript describes a miniaturized immunofluorescence assay (mini-IFA) for measuring antibody response in patient blood samples. The automated method builds on machine-learning -guided image analysis with SARS-CoV-2 as the model pathogen. The method enables simultaneous measurement of IgM, IgA, and IgG responses against different virus antigens in a high throughput manner. The assay relies on antigens expressed through transfection and allows for differentiation between vaccine-induced and infection-induced antibody responses. The transfection-based antigen expression enables performing the assay at a low biosafety level laboratory and allows fast adaptation of the assay to emerging pathogens. Our results provide proof-of-concept for the approach, demonstrating fast and accurate measurement of antibody responses in a clinical and research set-up.