Elke Vanlaere

Mrs. Elke Vanlaere

AZ Sint-Lucas, Ghent, Belgium
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2022 in Viruses
Verified
Journal Article
Open access
PDF file
LCLize Cuypers
Lize Cuypers
JBJannes Bode
Jannes Bode
KBKurt Beuselinck
Kurt Beuselinck
LLLies Laenen
Lies Laenen
KDKlaas Dewaele
Klaas Dewaele
EAEmmanuel André
Emmanuel André
From early 2020, a high demand for SARS-CoV-2 tests was driven by several testing indications, including asymptomatic cases, resulting in the massive roll-out of PCR assays to combat the pandemic. Considering the dynamic of viral shedding during the course of infection, the demand to report cycle threshold (Ct) values rapidly emerged. As Ct values can be affected by a number of factors, we considered that harmonization of semi-quantitative PCR results across laboratories would avoid potential divergent interpretations, particularly in the absence of clinical or serological information. A proposal to harmonize reporting of test results was drafted by the National Reference Centre (NRC) UZ/KU Leuven, distinguishing four categories of positivity based on RNA copies/mL. Pre-quantified control material was shipped to 124 laboratories with instructions to setup a standard curve to define thresholds per assay. For each assay, the mean Ct value and corresponding standard deviation was calculated per target gene, for the three concentrations (107, 105 and 103 copies/mL) that determine the classification. The results of 17 assays are summarized. This harmonization effort allowed to ensure that all Belgian laboratories would report positive PCR results in the same semi-quantitative manner to clinicians and to the national database which feeds contact tracing interventions.

1 September 2015 in Diagnostic Microbiology and Infectious Disease
Verified
Journal Article
Closed access
SJStijn Jonckheere
Stijn Jonckheere
CVCharlotte Verfaillie
Charlotte Verfaillie
ABAn Boel
An Boel
KVKristien Van Vaerenbergh
Kristien Van Vaerenbergh
EVElke Vanlaere
Elke Vanlaere
HBHans De Beenhouwer
Hans De Beenhouwer

19 October 2021 in Journal of Medical Microbiology
Verified
Journal Article
Open access
KMKarel Maelegheer
Karel Maelegheer
MRMarijke Reynders
Marijke Reynders
KFKatelijne Floré
Katelijne Floré
JVJos Vanacker
Jos Vanacker
EVElke Vanlaere
Elke Vanlaere
MRMarijke Raymaekers
Marijke Raymaekers
Introduction.The FilmArray Meningitis/Encephalitis (FA-ME) Panel (Biofire, Salt Lake City, Utah, US) enables fast and automated detection of 14 pathogens in cerebrospinal fluid (CSF).Gap statement.The performance of the FA-ME panel in a real routine setting has not yet been described and could lead to better patient management in cases of good performance.Aim.This multicenter study verified the FA-ME panel analytical performance in a routine hospital setting.Methodology.Between April 2016 and April 2018, 454 CSF samples were analysed with the FA-ME panel and compared with routine diagnostics. In cases of discrepancy or lack of a comparator result, a profound analysis based on patient records and other laboratory results was performed.Results.A first analysis of 65 frozen samples, suspicious for meningitis had a 89 % concordance with routine diagnostics. The limit of detection (LOD) was confirmed for all pathogens except forStreptococcus agalactiaeand a strain ofHaemophilus influenzae (Escherichia coli K1andCryptococcus gattiiLOD experiments were not performed). The routine evaluation showed a positive result in 114 (25 %) clinical samples for at least one target. In three samples co-infections were found. After discrepancy analysis, overall sensitivity was 98 % (false negative FA-ME results for one HSV2, two HSV1 and two parechovirus). Four FA-ME results were considered false positive (two HHV6, one VZV and oneE. coli K1), resulting in an overall specificity of >99 %. A clinical added value of the assay was seen in the diagnosis of eight cases of bacterial meningitis.Conclusion.Because of its rapidity and ease of use, the FA-ME panel has great potential in the diagnosis of central nervous infections. Implementation can improve clinical management, but costs and analytical limitations need to be addressed to convince clinicians and laboratories of its value.