Bathymetric LiDAR technology is a technology used for simultaneous data acquisition regarding the morphology of the bottom of water reservoirs and the surrounding coastal zone, realized from the air, e.g., by plane or drone. Contrary to the air topographic LiDAR, which uses an infrared wavelength of 1064 nm, bathymetric LiDAR systems additionally use a green wavelength of 532 nm. The green laser can penetrate the water, which makes it possible to measure the depth of shallow water reservoirs, rivers, and coastal sea waters within three Secchi depths. This article presents the theoretical basis for the construction of a green laser. Against the background of other methods of measuring the bottom of water reservoirs, the technology using waves from the visible light range is presented in detail in the assessment of the bottom morphology of shallow water reservoirs. The possibilities of using green laser in lidar bathymetry implemented in particular in non-navigable regions are shown. The results of the researchers’ work on river processes (erosion, sedimentation), design of stream restoration, determination of morphometric parameters of the riverbed, as well as assessment of the topography of the marine coastal bottom zones are summarized. The development direction of lidar bathymetry is discussed.
This study examines the chlorophyll a content and turbidity in the shallow dam reservoir of Lake Dobczyce. The analysis of satellite images for thirteen wavelength ranges enabled the selection of wavelengths applicable for a remote determination of chlorophyll a and turbidity. The selection was completed as the test of the significance of the coefficients in the equation, which calculates the values of the parameters on the basis of reflectance. The reflectance of the reservoir surface differs from the reflectance of individual water components, and the overlapping of spectral curves makes it difficult to isolate the significant reflectance. In the case of Lake Dobczyce, the significant reflectance was for wavelengths 665, 705, 740, and 842 nm (chlorophyll a) and for wavelengths 705, 740, and 783 nm (turbidity). In the model, the natural logarithm of chlorophyll a or turbidity was a linear combination of the natural log reflectance and the squares of those logarithms. A lake surface reflectance also includes the bottom reflectance. The reflectance obtained from the Sentinel-2 satellite was corrected with a bottom reflectance determined using the Lambert–Beer equation. The reflectance of a given surface may vary with the position of both the satellite and the sun, atmospheric pollution, and other factors. Correction of reflectance from satellite measurements was performed, as reflectance changes for the reference surface; the reference reflectance was assumed as the first reflectance of the reference surface observed during the study. The models helped to develop the maps of turbidity and chlorophyll a content in the lake.
4 April 2022 in International Journal of Disaster Risk Reduction
The concept of obtaining uniform and high-precision 3D models of large and complex engineering structures based on terrestrial laser scanning surveys highly depends on the accuracy of registering a series of adjacent scans. If it is not possible to place the required number of reference points in the observation scene, and there are no identifiable structural elements that could serve as such reference points, the issue can be solved by using the virtual reference points. The virtual reference points are not marked, but their position can be re-created in the post-processing of the scans on the basis of the geometrical features of the object. In the case of an industrial chimney, these can be the structural axis points determined at arbitrarily selected altitudes. In the solution presented herein, the coordinates of the reference points were independently determined twice: in the geodetic coordinate system using traditional method, in the local system of the scanner using the bisector of the chord of the circle, and by approximation of the circular arc shape of the chimney shell. Both procedures are preceded by the filtration of outliers. The concept of virtual reference points was verified by the measurement of the verticality of the axis and the structural geometry of a steel industrial chimney, which was accessible only on the foundation level.
12 May 2026 in Geomatics and Environmental Engineering
The aim of the study was to assess the sedimentation of the Klimkówka reservoir using topographic differencing (TD) analysis of digital elevation models (DEMs) created for two periods: before the reservoir was filled and after30 years of operation. The archival model was developed from a scanned and calibrated analogue large-scale (1:5,000) topographic map with contour lines and elevation points. The current model was obtained by integrating unmanned aerial vehicle (UAV) photogrammetry and bathymetric measurements with a GNSS-positioned dual-frequency echo sounder. The accuracy of both models was analysed in detail, taking into account cartographic errors, map shrinkage, the scanning and calibration process, and the heterogeneous accuracy of the archival elevation data. Based on the DEM difference, the estimated sedimentation volume was considered unreliable. A detailed analysis of selected cross-sections revealed local accumulation processes in the backwater zone and slope erosion, but did not permit a reliable assessment of the siltation of the entire reservoir. The authors conclude that the reliable application of the TD method requires comparing two models produced with similarly high accuracy (e.g. UAV + bathymetry), while analogue cartographic materials from the 1970s do not meet current accuracy requirements for this type of analysis.