The aim of the present review was evaluate the utility and validity of the Bispectral Index (BIS) in dental treatment carried out under endovenous sedation, and compare its efficacy with clinical sedation scales. Electronic and manual literature searches were conducted by two independent reviewers for articles published up to April 2017 in several databases, including Medline and Cochrane Library. Sixteen articles met the inclusion criteria. A correlation was identified between BIS and clinical sedation scales. A BIS range between 75 and 84 showed a high probability of corresponding to an Observer’s Assessment of Alertness and Sedation Scale (OAA/S) value of 3; a scored 3 on the Ramsay scale corresponds around 85 on the BIS; while BIS values between 57 and 64 corresponded to a University of Michigan Sedation Scale value of 3. BIS monitoring provides continuous measurement of the patient’s hypnotic state or state of consciousness, awareness, and recall. It proved impossible to perform an analysis of statistical data drawn from the studies reviewed due to the disparity of inclusion criteria among the works. BIS for sedation monitoring might make possible to evaluate sedation levels objectively in real time, reducing the dose of the sedative required, increasing safety, and minimizing secondary effects. Key words:Bispectral analysis, BIS monitoring, intravenous sedation, dental treatment, anesthetics.
Very limited data are available on the hemodynamic and ventilatory changes during sedation and general anesthesia using bispectral index (BIS) monitoring in intellectually disabled children. The purpose was to determine the hemodynamic and ventilatory changes after propofol and sevoflurane administration in children with special needs (CSN) versus healthy children (HC) during dental treatment. Forty pediatric patients needing dental treatment were allocated into two groups: children without systemic disease (healthy children [HC]) and mentally disabled children (children with special needs [CSN]). Sevoflurane in oxygen (100% oxygen, 5 l/min) and continuous propofol infusion (target-controlled infusion [TCI], 2 µg/ml) were used as sedative agents, and 2% lidocaine with 1:80,000 adrenaline was used as local anesthesia in both groups. Heart rate (HR), oxygen saturation (SaO2), respiratory rate (RR), exhaled carbon dioxide (CO2), blood pressure (BP) and bispectral monitoring (BIS) values were recorded during the entire dental treatment procedure. A statistically significant decrease in systolic BP, diastolic BP and RR was observed, with no significant differences between the healthy and disabled groups. In contrast, the HR and BIS values were lower in the CSN group than in the healthy patients (p ≤ 0.05). Patients with special needs had lower HR and BIS values than healthy patients, while BP, SaO2 and exhaled CO2 showed similar results in both groups. Key words:Bispectral index, hemodynamic changes, ventilatory changes, pediatric patients, special needs.