Andreas Breidbach

Dr. Andreas Breidbach

European Commission Joint Research Centre, Brussels, Belgium
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2014 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
ABAndreas Breidbach
Andreas Breidbach
FUFranz Ulberth
Franz Ulberth
Aflatoxins, mycotoxins of fungi of the Aspergillus sp., pose a risk to consumer health and are, therefore, regulated by more than 100 countries. To facilitate method development and validation as well as assessment of measurement capabilities, availability of certified reference materials and proficiency testing schemes is important. For these purposes, highly accurate determinations of the aflatoxin content in the materials used are necessary. We describe here the use of two-dimensional heart-cut LC-LC in combination with exact-matching double isotope dilution mass spectrometry to determine the content of aflatoxin B1 in three materials used in a proficiency testing scheme. The serious reduction in ionization suppression afforded by the two-dimensional heart-cut LC-LC had a positive effect on the precision of the measured isotope ratios of the exact-matching double isotope dilution mass spectrometry. This is evidenced by the expanded measurement uncertainty (k = 2) of 0.017 μg/kg or 8.9 % relative to a mass fraction of aflatoxin B1 in a cereal-based baby food of 0.197 μg/kg. This value is in perfect agreement with the consensus value of this material from a proficiency test (PT) scheme for National Reference Laboratories executed by the European Reference Laboratory for Mycotoxins. The effort necessary to perform the described methodology precludes its frequent use but for specific applications we see it as a valuable tool.

7 March 2017 in Toxins
Verified
Journal Article
Open access
PDF file
ABAndreas Breidbach
Andreas Breidbach
In food/feed control, mycotoxin analysis is often still performed “one analyte at a time”. Here a method is presented which aims at making mycotoxin analysis environmentally friendlier through replacing acetonitrile by ethyl acetate and reducing chemical waste production by analyzing four mycotoxins together, forgoing sample extract clean-up, and minimizing solvent consumption. For this, 2 g of test material were suspended in 8 mL water and 16 mL ethyl acetate were added. Extraction was accelerated through sonication for 30 min and subsequent addition of 8 g sodium sulfate. After centrifugation, 500 µL supernatant were spiked with isotopologues, dried down, reconstituted in mobile phase, and measured with LC-MS. The method was validated in-house and through a collaborative study and the performance was fit-for-purpose. Repeatability relative standard deviation (RSDs) between 16% at low and 4% at higher contaminations were obtained. The reproducibility RSDs were mostly between 12% and 32%. The trueness of results for T-2 toxin and Zearalenone were not different from 100%, for Deoxynivalenol and HT-2 toxin they were larger than 89%. The extraction was also adapted to a quick screening of Aflatoxin B1 in maize by flow-injection–mass spectrometry. Semi-quantitative results were obtained through standard addition and scan-based ion ratio calculations. The method proved to be a viable greener and quicker alternative to existing methods.

13 February 2025 in Separations
Verified
Journal Article
Open access
PDF file
VPViviana Paiano
Viviana Paiano
ABAndreas Breidbach
Andreas Breidbach
CLCarolin Lörchner
Carolin Lörchner
TŽTereza Ždiniaková
Tereza Ždiniaková
OROlivier De Rudder
Olivier De Rudder
FUFranz Ulberth
Franz Ulberth
Honey, a sweet and nutritious food produced by honeybees, is extensively consumed by humans due to its potential health benefits. Unfortunately, the adulteration of honey with inexpensive sugar syrups is a prevalent issue. Verifying the authenticity of honey is crucial for maintaining its quality and safety standards. The aim of this study was to identify the illicit addition of sugar syrups to honey imported into the European Union (EU). The European Commission’s Joint Research Centre (JRC) has employed different analytical approaches to detect several markers of adulteration in honey; however, this paper mainly focuses on the use of Liquid Chromatography–High-Resolution Mass Spectrometry (LC-HRMS). Two qualitative methods were developed to detect mannose (Man), difructose anhydride III (DFA III), 2-acetylfuran-3-glucopyranoside (AFGP), and oligo-/polysaccharides with degrees of polymerization (DPs) of 6 to 11. Out of the 320 honey samples provided by the authorities of the participating EU Member States, 147 (46%) were suspicious for non-compliance with the EU Honey Directive 2001/110/EC, mostly due to the presence of mannose and oligo-/polysaccharides. As a result, the development and standardization of sophisticated and universally recognized testing procedures will increase the capability of official control laboratories to detect honey adulteration and will serve as a powerful preventive measure against fraudulent practices in the global honey market.

1 June 2016 in Food Chemistry
Verified
Journal Article
Open access
ABAndreas Breidbach
Andreas Breidbach
FUFranz Ulberth
Franz Ulberth
Irradiation of food products and ingredients must be indicated by proper labeling. This study evaluated the appropriateness of the European Standard EN 1785:2003 for the detection of 2-alkylcyclobutanones, which are radiolysis products of fatty acids, in cashew nuts and nutmeg and confirmed its suitability to detect irradiation of cashew nut samples at average absorbed doses of 1 kGy and above. An alternative method was developed, which is based on matrix solid phase dispersion and subsequent separation and detection of oxime derivatives of 2-alkylcyclobutanones by high performance-high resolution mass spectrometry. It is more rapid, less resource consuming, and more sensitive than EN 1785:2003. This method allowed detection of 2-alkylcyclobutanones in cashew nuts irradiated at 100 Gray and in nutmeg irradiated at 400 Gray. None of the 26 cashew nut and 14 nutmeg samples purchased in different EU Member States contained traces of 2-alkylcyclobutanones.

18 March 2022 in Foods
Verified
Journal Article
Open access
PDF file
ABAndreas Breidbach
Andreas Breidbach
JNJørgen Nørgaard
Jørgen Nørgaard
ECElena Cubero-Leon
Elena Cubero-Leon
MEMaria Jose Martinez Esteso
Maria Jose Martinez Esteso
Interlaboratory comparisons (ILC) in the food allergens field mainly rely on the use of consensus values per applied methodology or even per type of an ELISA test kit. Results suggest good reproducibility; however, possible biases may not be recognized since metrological traceability to an independent reference is lacking. The work presented here utilizes isotope dilution mass spectrometry (IDMS) to assign a reference value of the total cow’s milk protein (TCMP) content in a baked cookie and its associated uncertainty. TCMP consists of several individual proteins, of which five (representing 92%) served us as markers for TCMP. Per marker, one to four proteotypic peptides were selected for the quantification. These were synthesized, and the mass fractions of respective reference solutions were determined with peptide-impurity-corrected amino acid analysis to establish traceability to SI units. Stable isotope labelled (“heavy”) analogues of the proteotypic peptides were also synthesized and blended with extracts of the test material or the reference solutions for IDMS. Through careful measurement design minimizing biases, well-defined model equations were developed, allowing appropriate estimation of the associated uncertainty. The determined reference value of 11.8 ± 1.1 mg TCMP/kg cookie was used for scoring of a novel ILC.

9 September 2026 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
ABAndreas Breidbach
Andreas Breidbach
Polyethylene terephthalate (PET) microplastics are pervasive pollutants, yet reliable quantification is hampered by the scarcity of standardized protocols