MOHD NASIR

Dr. MOHD NASIR

Aligarh Muslim University, Aligarh, India
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
NRNafisur Rahman
Nafisur Rahman
MOHD NASIRMOHD NASIR
MOHD NASIR


20 July 2021 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
SASyed Najmul Hejaz Azmi
Syed Najmul Hejaz Azmi
BABushra Mohammed Hamed Al-Jassasi
Bushra Mohammed Hamed Al-Jassasi
HAHiba Mohammed Saif Al-Sawafi
Hiba Mohammed Saif Al-Sawafi
SASahar Harib Gharib Al-Shukaili
Sahar Harib Gharib Al-Shukaili
NRNafisur Rahman
Nafisur Rahman
MOHD NASIRMOHD NASIR
MOHD NASIR

1 October 2017 in Journal of Water Process Engineering
Verified
Journal Article
Closed access
NRNafisur Rahman
Nafisur Rahman
MOHD NASIRMOHD NASIR
MOHD NASIR

9 November 2022 in Separations
Verified
Journal Article
Open access
PDF file
SASyed Najmul Hejaz Azmi
Syed Najmul Hejaz Azmi
UHUmaima Al Hoqani
Umaima Al Hoqani
JMJuhaina Obaid Said Al Mamari
Juhaina Obaid Said Al Mamari
BMButhaina Mohamed Salim Al Mamari
Buthaina Mohamed Salim Al Mamari
BJBalaqis Sultan Ali Rashid Al Jassasi
Balaqis Sultan Ali Rashid Al Jassasi
ZZZainul Amiruddin Zakaria
Zainul Amiruddin Zakaria
A simple, sensitive, accurate and inexpensive UV-reversed-phase high-performance liquid chromatographic method was developed for the determination of ascorbic acid in tablet formulations. The method was based on the separation of ascorbic acid using a mobile phase of an acetonitrile-NaH2PO4-H3PO4 buffer solution (pH = 3) (5:95 v/v) with a UV detection wavelength of 245 nm and a flow rate of 0.8 mL min−1 at ambient column temperature. The variables of the proposed method, such as acetonitrile fraction (%), flow rate (mL min−1) and column temperature (°C), were optimized on the peak area by response surface methodology via the Box–Behnken design. The mobile phase was passed isocratically, and the separation of ascorbic acid was performed at the retention time of 4.1 min. A calibration graph was obtained and found to be linear in the concentration range of 10–180 µg mL−1. The method suitability was assessed and an asymmetry factor of 1.15 was obtained. The proposed method was successfully applied for the determination of ascorbic acid in tablet formulations and statistically compared with the results of the reference method. The performance of the proposed method was excellent and in agreement with the reference method. The recovery percentage of the proposed and reference methods was in the range of 99.98–100.04% and showed compliance (100 ± 2%) with regulatory guidelines.

7 February 2019 in ACS Omega
Verified
Journal Article
Open access
NRNafisur Rahman
Nafisur Rahman
MOHD NASIRMOHD NASIR
MOHD NASIR
In this study, N-(((2-((2-aminoethyl)amino)ethyl)amino)methyl)-4-sulfamoylbenzamide was impregnated into the hydrous zirconium oxide matrix to yield N-(((2-((2-aminoethyl)amino)ethyl)amino)methyl)-4-sulfamoylbenzamide/hydrous zirconium oxide composite (AESB/HZO). The composite material was used to remove Ni(II) from aqueous environment. AESB/HZO was characterized using Fourier transform infrared, scanning electron microscopy with energy dispersive X-ray, and thermogravimetry–differential thermal analyses. An experimental design approach was utilized to model and optimize the variables of adsorption of Ni(II) onto the AESB/HZO composite. Four experimental parameters were selected as independent variables: contact time, pH, adsorbent dose, and initial Ni(II) concentration. A multivariable experimental design was used to establish quadratic model to describe the relationship between percent removal of Ni(II) and four independent variables. At the optimum conditions (contact time: 85 min, pH: 6, adsorbent dose: 10 mg/20 mL, and initial Ni(II) concentration: 20 mg L–1), high removal efficiency (99.35%) was achieved, which is reasonably well predicted by the quadratic model. The sorption of Ni(II) is dependent on pH and ionic strength at pH < 6.0. At low pH, −NH and −NH2 groups are protonated, whereas the −SO2– group is available for binding with Ni(II) and the sorption of Ni(II) is mainly governed by outer sphere surface complexation. In the pH range 6.0–7.5, −NH, −NH2, and −SO2– groups are available for binding with Ni(II) and the sorption is mainly governed by inner-sphere surface complexation. Adsorption isotherm data fitted well to the Langmuir model and the maximum adsorption capacity was found to be 96.03 mg g–1 at 303 K. The results of present investigation demonstrated that AESB/HZO has a good potential for Ni(II) removal from aqueous solution.