The lumen diameter reduction after percutaneous coronary intervention (PCI) is well known as “restenosis”. This phenomenon is due to vessel remodeling/recoil in case of no-stent strategy or, in case of stent employ, “neointimal proliferation” that consists in an excessive tissue proliferation in the luminal surface of the stent otherwise by a further new-occurring atherosclerotic process called “neoatherosclerosis”. The exact incidence of in-stent restenosis (ISR) is not easy to determine caused by different clinical, angiographic and operative factors. In the pre-stent era the occurrence of restenosis ranged between 32–55% of all angioplasties, and drop to successively 17–41% in the bare metal stents (BMS) era. The advent of drug-eluting stent (DES), especially 2nd generation, and drug-coated balloon (DCB) further reduce restenosis rate until <10%. We here review the main characteristics of this common complication of coronary interventions, from its pathogenesis to the most appropriate treatment strategy.
Background Percutaneous coronary intervention (PCI) of small vessels is limited by an increased risk of restenosis and adverse outcome, even when drug-eluting stents (DES) are employed. In recent years, the paclitaxel-coated balloon (PCB) has been shown to reduce neointimal proliferation and the need for target lesion revascularization (TLR) in an in-stent restenosis setting. The impact of a PCB during PCI of small coronary vessels was evaluated and compared to one of the most widely used DES. Methods In the PICCOLETO randomised clinical trial, patients with stable or unstable angina undergoing PCI of small coronary vessels (≤2.75 mm) were randomised to Dior PCB (28 patients) or Taxus DES (29 patients). The primary study end point was per cent diameter stenosis at 6-month angiographic follow-up (non-inferiority), secondary end points were angiographic binary restenosis and occurrence of major adverse cardiac events (MACE: death, Q-wave myocardial infarction, TLR) at 9 month follow-up. Results The two groups were not dissimilar regarding clinical and angiographic characteristics. Study was interrupted after enrolment of two-thirds of patients due to a clear superiority of one study group. The primary end point was not met, because the PCB group showed higher per cent diameter stenosis (43.6% vs 24.3%, p=0.029); angiographic restenosis was higher as well (32.1 vs 10.3%, p=0.043), whereas MACE were 35.7% in the PCB group and 13.8% in the DES group (p=0.054). Conclusions Dior PCB failed to show equivalence to Taxus DES regarding angiographic end points during PCI of small coronary arteries. Clinical Trial Registration Number (EudraCT code) 2009-012268-15.
1 December 2020 in JACC: Cardiovascular Interventions