MUATAZ AHMED R OSMAN

Dr. MUATAZ AHMED R OSMAN

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MOMUATAZ AHMED R OSMAN
MUATAZ AHMED R OSMAN
RARasha Alamoush
Rasha Alamoush
EKEvgeny Kushnerev
Evgeny Kushnerev
KSKevin Guy Seymour
Kevin Guy Seymour
SSSusan Shawcross
Susan Shawcross
JYJulian Yates
Julian Yates
Objectives: This study aimed to investigate human osteoblast (HOB) responses towards different degrees of titanium (Ti) implant surface roughness. Methods: Four degrees of Ti surface roughness were investigated on a micrometer roughness scale: smooth (S: 0.08–0.1 µm), minimally rough (MM: 0.3–0.5 µm), moderately rough (MR: 1.2–1.4 µm), and rough (R: 3.3–3.7 µm). HOB cells were cultured, expanded, and maintained according to the supplier’s protocol. Cell proliferation and cytotoxicity were assessed at day 1, 3, 5, and 10 using alamarBlue and lactate dehydrogenase colorimetric assays. Data were analyzed with one-way ANOVA, two-way ANOVA, and Tukey’s post hoc test (p = 0.05 for all tests). Results: There was no significant difference in the cell proliferation or cytotoxicity of the HOB cells in contact with the different degrees of Ti surface roughness. There was, however, a significant time effect on cell proliferation (p < 0.0001) with different exposure durations for each roughness degree. Furthermore, a positive correlation (non-significant) between proliferation and cytotoxicity was observed for all investigated degrees of surface roughness. Conclusion: All investigated roughness degrees showed comparable HOB proliferation, with the MR surface presenting the highest percentage, followed by the R, MM, ad S, surfaces, respectively. The S surface showed the highest cytotoxic effect on HOBs; however, it did not reach the cytotoxic level suggested by the ISO for any medical device to be considered cytotoxic.

17 October 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MOMUATAZ AHMED R OSMAN
MUATAZ AHMED R OSMAN
EKEvgeny Kushnerev
Evgeny Kushnerev
RARasha Alamoush
Rasha Alamoush
KSKevin Guy Seymour
Kevin Guy Seymour
JYJulian Yates
Julian Yates
Objectives: This study aimed to investigate the response of human gingival fibroblasts (HGFB) and human gingival keratinocytes (HGKC) towards different dental implant abutment materials. Methods: Five materials were investigated: (1) titanium (Ti), (2) titanium nitride (TiN), (3) cobalt-chromium (CoCr), (4) zirconia (ZrO2), and (5) modified polyether ether ketone (m-PEEK). Both cell lines were cultured, expanded, and seeded in accordance with the protocol of their supplier. Cell proliferation and cytotoxicity were evaluated at days 1, 3, 5, and 10 using colourimetric viability and cytotoxicity assays. Data were analysed via two-way ANOVA, one-way ANOVA, and Tukey’s post hoc test (p < 0.05 for all tests). Results: There was a statistically significant difference in cell proliferation of HGKC and HGFB cells in contact with different abutment materials at different time points, with no significant interaction between different materials. There was a significant effect on cell proliferation and cytotoxicity with different exposure times (p < 0.0001) for each material. Cell proliferation rates were comparable for both cell lines at the beginning of the study, however, HGFB showed higher proliferation rates for all materials at day 10 with better proliferation activities with ZrO and m-PEEK (40.27%) and (48.38%) respectively. HGKC showed significant interactions (p < 0.0001) in cytotoxicity between different materials. Conclusion: The present in vitro assessment investigated the biocompatibility of different abutment materials with soft tissue cells (HGFB and HGKC). The findings suggest that m-PEEK and TiN are biologically compatible materials with human cells that represent the soft tissue and can be considered as alternative implant abutment materials to Ti and ZrO2, especially when the aesthetic is of concern.

28 July 2022 in Dental Materials
Verified
Journal Article
Open access
MOMUATAZ AHMED R OSMAN
MUATAZ AHMED R OSMAN
RARasha A. Alamoush
Rasha A. Alamoush
EKEvgeny Kushnerev
Evgeny Kushnerev
KSKevin.G. Seymour
Kevin.G. Seymour
SSSusan Shawcross
Susan Shawcross
JYJulian Yates
Julian Yates
This study aimed to investigate human osteoblasts (HOB) response towards different dental implant abutment materials. Five dental implant abutment materials were investigated: (1) titanium (Ti), (2) titanium coated nitride (TiN), (3) cobalt chromium (CoCr), (4) zirconia (ZrO₂), and (5) modified polyether ether ketone (m-PEEK). HOBs were cultured, expanded, and seeded according to the supplier's protocol (PromoCell, UK). Cell proliferation and cytotoxicity were evaluated at days 1, 3, 5, and 10 using Alamar Blue (alamarBlue) and lactate dehydrogenase (LDH) colorimetric assays. Data were analysed via two-way ANOVA, one-way ANOVA and Tukey's post hoc test (significance was determined as p < 0.05 for all tests). All the investigated materials showed high and comparable initial proliferation activities apart from ZrO₂ (46.92%), with P% of 79.91%, 68.77%, 73.20%, and 65.46% for Ti, TiN, CoCr, and m-PEEK, respectively. At day 10, all materials exhibited comparable and lower P% than day 1 apart from TiN (70.90%) with P% of 30.22%, 40.64%, 37.27%, and 50.65% for Ti, CoCr, ZrO₂, and m-PEEK, respectively. The cytotoxic effect of the investigated materials was generally low throughout the whole experiment. At day 10, the cytotoxicity % was 7.63%, 0.21%, 13.30%, 5.32%, 8.60% for Ti, TiN, CoCr, ZrO₂, and m-PEEK. The Two-way ANOVA and Tukey's Multiple Comparison Method highlighted significant material and time effects on cell proliferation and cytotoxicity, and a significant interaction (p < 0.0001) between the tested materials. Notably, TiN and m-PEEK showed improved HOB proliferation activity and cytotoxic levels than the other investigated materials. In addition, a non-significant negative correlation between viability and cytotoxicity was found for all tested materials. Ti (p = 0.07), TiN (p = 0.28), CoCr (p = 0.15), ZrO₂ (p = 0.17), and m-PEEK (p = 0.12). All the investigated materials showed excellent biocompatibility properties with more promising results for the newly introduced TiN and m-PEEK as alternatives to the traditionally used dental implant and abutment materials.