Background and Aim: Passive hip laxity (PHL) is considered the primary risk factor for canine hip dysplasia (HD) and is estimated, in stress hip radiographs, using the distraction index (DI). The study aimed to associate the early PHL using the hip Distractor of University of Trás-os-Montes and Alto Douro (DisUTAD) and the late HD grades. Materials and Methods: A total of 41 dogs (82 hips) were submitted to a follow-up study. First, between 4 and 12 months of age, dogs were radiographed using the DisUTAD hip distractor and were determined the DI for each hip joint. Then, after 12 months of age, dogs were reevaluated for HD using the conventional hip ventrodorsal projection and hips were evaluated for HD using the Fédération Cynologique Internationale (FCI) scoring system. Results: Hips of dogs' in the second examination with FCI grades of A (n=28), B (n=11), C (n=22), and D and E (n=21) had an early DI of 0.32±0.1, 0.38±0.08, 0.50±0.12, and 0.64±0.11, respectively. Statistical analysis using the general linear model univariate, with the DI as dependent variable and the FCI grades, side and sex as fixed factors, and the post hoc Bonferroni correction test showed significant differences among FCI grades (p<0.05). Conclusion: These results show the association between early DI and the late FCI HD grades and the DisUTAD is recommended for the early canine HD diagnosis.
1 August 2020 in Arquivo Brasileiro de Medicina Veterinária e Zootecnia
The aim of this study was to test the accuracy of a new automated computer software tool for the assessment of passive hip laxity. The hip laxity was estimated using the dedicated computer software by two blinded evaluators, one previously trained and one without specific training for distraction index measurement, in two independent sessions using 230 hip joints from 115 dogs that underwent screening for passive hip laxity using the distraction view. Previously, all of these radiographs were sent to PennHIP Analysis Center for an official distraction index record. The measurement repeatability of the two sessions was adequate for both evaluators. The reproducibility of the official distraction index measurement, mean distraction index±standard deviation 0.44±0.15, was adequate (P>0.05) for the trained evaluator, 0.44±0.15, and non-adequate (P<0.05), for the non-trained evaluator 0.47±0.17. The distraction index measurement tool proposed can be used with confidence for hip laxity evaluation by trained evaluators, as it provided good repeatability and reproducibility of official reports. The simplicity of the process described leads to a less time-consuming and more affordable procedure.