Pathipooranam Ponnambalam

Dr. Pathipooranam Ponnambalam


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Energy Conversion and Management
Verified
Journal Article
Closed access
CBChalla Babu
Challa Babu
PPPathipooranam Ponnambalam
Pathipooranam Ponnambalam

14 July 2022 in Frontiers in Energy Research
Verified
Journal Article
Open access
RPR. Parthiban
R. Parthiban
PPPathipooranam Ponnambalam
Pathipooranam Ponnambalam
Recently solar panels are gaining popularity in the field of non-conventional energy sources for generating green and clean electric power. On the negative side, the photovoltaic efficiency is reduced with an increase in ambient temperature. The production of energy is dropped by 0.33% for every degree Celsius above STC. Consequently, the electric power which is generated by the solar panel may not be sufficient to run the load. It is important to realize that in some applications, such as standalone electric vehicles, space for providing an additional solar panel to compensate for the decremented output power may not be feasible. By implementing the cooling arrangements, this excessive heat might be reduced. Several cooling techniques have been implemented, named as active and passive methods. This article presents a review on maximizing the efficiency of the solar panel by utilizing different cooling methods and by integrating TEG with solar panels.

4 June 2021 in IEEE Access
Verified
Journal Article
Open access
KMKola Muralikumar
Kola Muralikumar
PPPathipooranam Ponnambalam
Pathipooranam Ponnambalam
The modified topology for an asymmetrical 31-level cascaded inverter is analyzed with less number of DC voltage sources, power diodes, and power electronic knobs. The Super Imposed Carrier Pulse Width Modulation (SIC-PWM) is proposed for a 31-level asymmetrical modified cascaded inverter topology to reduce the Total Harmonic Distortions (THD). The Fuzzy logic controller (FLC) and Adaptive Neuro-Fuzzy Inference System (ANFIS) are suggested for a 31-level asymmetrical modified cascaded inverter topology to control the root mean square (RMS) voltage. These controllers help in maintaining the output voltage constant even when there is a change in input voltage to the inverter. This study aims to compare Fuzzy logic and ANFIS controllers by applying them to the 31-level cascaded inverter. Using both the controllers the inverter is controlled and its performance is compared using a step response tool in MATLAB. The study of the proposed modified 31-level Asymmetrical cascaded inverter is carried out to evaluate the THD without and with Fuzzy logic and ANFIS controller. Using the step response tool, Settling Time, Overshoot, RMS Voltage values, Peak Time, Peak value, and Rise Time were evaluated and compared for Fuzzy and ANFIS controlled 31-level asymmetrical cascaded inverter. The THD value for without a controller is 4.97%, with the fuzzy logic controller is 4.15% and with ANFIS controller is 3.77%. In both MatLab and real-time simulation, total harmonic distortion (THD) is observed to be the almost same and is lower than 5% which is under IEEE standards. The performance of Fuzzy and ANFIS controlled 31-level asymmetrical cascaded inverter is evaluated and compared with the use of MATLAB/Simulink and the same is done with Real-Time simulation using OPAL-RT 5700.

20 September 2020 in IETE Journal of Research
Verified
Journal Article
Closed access
KMKola Muralikumar
Kola Muralikumar
PPPathipooranam Ponnambalam
Pathipooranam Ponnambalam
Multilevel inverters (MLI) are aligned with lower harmonics and less commutation losses, which offer high power capacity. MLI is one of the best widespread converters due to its ability to eliminate the harmonic distortion without dropping the converter power output. The cascaded MLI is utilized for a reduced number of switches. In this topology, the switching angles at fundamental frequency are attained by solving the selective harmonic eliminations using sine cosine algorithm. This attains the desired output voltage with the elimination of certain lower order harmonics. In this paper, the analysis of seven-level cascaded MLI is presented with the scheme of carrier-based modulation techniques i.e. Phase-Disposition (PD), Phase-Opposition Disposition (POD) and Alternative Phase-Opposition Disposition (APOD). The Artificial intelligence (AI) is carried out for PD technique. These techniques are capable of defining the required switching angles to eliminate the preferred values of harmonics. The harmonic contents of output voltage in carrier-based modulation are observed with the indices, such as the modulation index with frequency modulation index and amplitude modulation index. The simulation results are obtained for seven-level inverter using MATLAB/SIMULINK. The hardware implementation is carried out using Main Power Management IC TPS65217C Beagle Bone Black Board for seven-level open loop control to justify the achievement of the suggested topology.

1 June 2017 in Energy Procedia
Verified
Journal Article
Open access
PPPathipooranam Ponnambalam
Pathipooranam Ponnambalam
KMK Muralikumar
K Muralikumar
PVP Vasundhara
P Vasundhara
SSS Sreejith
S Sreejith
CBChalla Babu
Challa Babu

19 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
MPMurthy Priya
Murthy Priya
PPPathipooranam Ponnambalam
Pathipooranam Ponnambalam
The contribution of the modular multilevel converter (MMC) in integrating non-conventional energy sources into the grid is significant; the integration of fuel cells with distributed energy sources is especially prominent as they provide a constant voltage and current for constant load applications. Still, there is a high demand for a high-quality power conditioning unit since there is an occurrence of frequent power spikes. Further, the circulating current (CC) in phase legs is an inherent phenomenon of MMC that must be mitigated. Hence, this article proposed an MMC incorporating a fuzzy logic controller (FLC)-based technique to control the circulating currents. The fuzzy controller effectively reduced the harmonics of the CC in the dc-link system. In addition, phase-shifted carrier (PSC) modulation was employed for the MMC to improve the capacitor voltage balancing to maintain the constant input voltage. Moreover, a mathematical analysis of PSC modulation for MMC was performed to identify the PWM harmonic characteristics of the output voltage and the CC. The performance analysis of the proposed system was tested using the hardware in loop (HIL) simulation with the help of the real-time simulator OP-5700 to verify the feasibility.