Iman Aganj

Dr. Iman Aganj

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
IAIman Aganj
Iman Aganj
CLChristophe Lenglet
Christophe Lenglet
GSGuillermo Sapiro
Guillermo Sapiro
EYEssa Yacoub
Essa Yacoub
KUKamil Ugurbil
Kamil Ugurbil
NHNoam Harel
Noam Harel
Q‐Ball imaging is a high‐angular‐resolution diffusion imaging technique that has been proven very successful in resolving multiple intravoxel fiber orientations in MR images. The standard computation of the orientation distribution function (the probability of diffusion in a given direction) from q‐ball data uses linear radial projection, neglecting the change in the volume element along each direction. This results in spherical distributions that are different from the true orientation distribution functions. For instance, they are neither normalized nor as sharp as expected and generally require postprocessing, such as artificial sharpening. In this paper, a new technique is proposed that, by considering the solid angle factor, uses the mathematically correct definition of the orientation distribution function and results in a dimensionless and normalized orientation distribution function expression. Our model is flexible enough so that orientation distribution functions can be estimated either from single q‐shell datasets or by exploiting the greater information available from multiple q‐shell acquisitions. We show that the latter can be achieved by using a more accurate multiexponential model for the diffusion signal. The improved performance of the proposed method is demonstrated on artificial examples and high‐angular‐resolution diffusion imaging data acquired on a 7‐T magnet. Magn Reson Med, 2010.

1 August 2011 in Medical Image Analysis
Verified
Journal Article
Closed access
IAIman Aganj
Iman Aganj
CLChristophe Lenglet
Christophe Lenglet
NJNeda Jahanshad
Neda Jahanshad
EYEssa Yacoub
Essa Yacoub
NHNoam Harel
Noam Harel
GSGuillermo Sapiro
Guillermo Sapiro

3 February 2015 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
JGJason L. Gaglia
Jason L. Gaglia
MHMukesh Harisinghani
Mukesh Harisinghani
IAIman Aganj
Iman Aganj
GWGregory R. Wojtkiewicz
Gregory R. Wojtkiewicz
SHSandeep Hedgire
Sandeep Hedgire
RWRalph Weissleder
Ralph Weissleder
Significance: We describe a readily exportable method for noninvasive imaging of the pancreatic inflammation underlying type-1 diabetes (T1D), based on MRI of the clinically approved magnetic nanoparticle ferumoxytol. This approach, which reflects nanoparticle uptake by macrophages in the inflamed pancreatic lesion, has been validated rigorously in mouse T1D models. Methodological advances reported here include extensive optimization of image acquisition and improved MRI registration and visualization technologies. A proof-of-principle study revealed a clear difference in whole-pancreas nanoparticle accumulation in patients with recent-onset T1D versus healthy controls and pronounced intra- and interpancreatic signal heterogeneity in patients. Noninvasive generation of 3D, high-resolution maps of pancreatic inflammation should prove invaluable in assessing T1D progression and as an indicator of response to therapy.

29 August 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
IAIman Aganj
Iman Aganj
MHMukesh G. Harisinghani
Mukesh G. Harisinghani
RWRalph Weissleder
Ralph Weissleder
BFBruce Fischl
Bruce Fischl
Image segmentation is a critical step in numerous medical imaging studies, which can be facilitated by automatic computational techniques. Supervised methods, although highly effective, require large training datasets of manually labeled images that are labor-intensive to produce. Unsupervised methods, on the contrary, can be used in the absence of training data to segment new images. We introduce a new approach to unsupervised image segmentation that is based on the computation of the local center of mass. We propose an efficient method to group the pixels of a one-dimensional signal, which we then use in an iterative algorithm for two- and three-dimensional image segmentation. We validate our method on a 2D X-ray image, a 3D abdominal magnetic resonance (MR) image and a dataset of 3D cardiovascular MR images.

1 January 2018 in NeuroImage
Verified
Journal Article
Closed access
HWHui Wang
Hui Wang
CMCaroline Magnain
Caroline Magnain
RWRuopeng Wang
Ruopeng Wang
JDJay Dubb
Jay Dubb
AVAni Varjabedian
Ani Varjabedian
DBDavid A. Boas
David A. Boas

1 July 2019 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
MMManuel A. Morales
Manuel A. Morales
DIDavid Izquierdo-Garcia
David Izquierdo-Garcia
IAIman Aganj
Iman Aganj
JKJayashree Kalpathy-Cramer
Jayashree Kalpathy-Cramer
BRBruce R. Rosen
Bruce R. Rosen
CCCiprian Catana
Ciprian Catana
To describe an unsupervised three-dimensional cardiac motion estimation network (CarMEN) for deformable motion estimation from two-dimensional cine MR images. A function was implemented using CarMEN, a convolutional neural network that takes two three-dimensional input volumes and outputs a motion field. A smoothness constraint was imposed on the field by regularizing the Frobenius norm of its Jacobian matrix. CarMEN was trained and tested with data from 150 cardiac patients who underwent MRI examinations and was validated on synthetic (n = 100) and pediatric (n = 33) datasets. CarMEN was compared to five state-of-the-art nonrigid body registration methods by using several performance metrics, including Dice similarity coefficient (DSC) and end-point error. On the synthetic dataset, CarMEN achieved a median DSC of 0.85, which was higher than all five methods (minimum–maximum median [or MMM], 0.67–0.84; P < .001), and a median end-point error of 1.7, which was lower than (MMM, 2.1–2.7; P < .001) or similar to (MMM, 1.6–1.7; P > .05) all other techniques. On the real datasets, CarMEN achieved a median DSC of 0.73 for Automated Cardiac Diagnosis Challenge data, which was higher than (MMM, 0.33; P < .0001) or similar to (MMM, 0.72–0.75; P > .05) all other methods, and a median DSC of 0.77 for pediatric data, which was higher than (MMM, 0.71–0.76; P < .0001) or similar to (MMM, 0.77–0.78; P > .05) all other methods. All P values were derived from pairwise testing. For all other metrics, CarMEN achieved better accuracy on all datasets than all other techniques except for one, which had the worst motion estimation accuracy. The proposed deep learning–based approach for three-dimensional cardiac motion estimation allowed the derivation of a motion model that balances motion characterization and image registration accuracy and achieved motion estimation accuracy comparable to or better than that of several state-of-the-art image registration algorithms. © RSNA, 2019 Supplemental material is available for this article.