Fernando U. Kay

Dr. Fernando U. Kay


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Open access
SSScott Simpson
Scott Simpson
FKFernando U. Kay
Fernando U. Kay
SASuhny Abbara
Suhny Abbara
SBSanjeev Bhalla
Sanjeev Bhalla
JCJonathan Chung
Jonathan Chung
HLHarold Litt
Harold Litt
Indings that could be attributable to COVID-19 pneumonia, requiring radiologists to decide whether or not to mention COVID-19 specifically as a differential diagnostic possibility. We aim to provide guidance to radiologists in reporting CT findings potentially attributable to COVID-19 pneumonia, including standardized language to reduce reporting variability when addressing the possibility of COVID-19. When typical or indeterminate features of COVID-19 pneumonia are present in endemic areas as an incidental finding, we recommend contacting the referring providers to discuss the likelihood of viral infection. These incidental findings do not necessarily need to be reported as COVID-19 pneumonia. In this setting, using the term “viral pneumonia” can be a reasonable and inclusive alternative. However, if one opts to use the term “COVID-19” in the incidental setting, consider the provided standardized reporting language. In addition, practice patterns may vary, and this document is meant to serve as a guide. Consultation with clinical colleagues at each institution is suggested to establish a consensus reporting approach. The goal of this expert consensus is to help radiologists recognize findings of COVID-19 pneumonia and aid their communication with other healthcare providers, assisting management of patients during this pandemic. S.S. and F.U.K. are co-first authors. Published under a CC BY 4.0 license. The authors declare no conflicts of interest. Correspondence to: Harold Litt, MD, PhD, Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104 (e-mail: harold.litt@uphs.upenn.edu). Article was originally published in Radiology: Cardiothoracic Imaging. Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved...

1 December 2018 in Anesthesiology
Verified
Journal Article
Closed access
SPSérgio M. Pereira
Sérgio M. Pereira
MTMauro R. Tucci
Mauro R. Tucci
CMCaio C. A. Morais
Caio C. A. Morais
CSClaudia M. Simões
Claudia M. Simões
BTBruno F. F. Tonelotto
Bruno F. F. Tonelotto
MAMarcelo B. P. Amato
Marcelo B. P. Amato
Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: Background: Intraoperative lung-protective ventilation has been recommended to reduce postoperative pulmonary complications after abdominal surgery. Although the protective role of a more physiologic tidal volume has been established, the added protection afforded by positive end-expiratory pressure (PEEP) remains uncertain. The authors hypothesized that a low fixed PEEP might not fit all patients and that an individually titrated PEEP during anesthesia might improve lung function during and after surgery. Methods: Forty patients were studied in the operating room (20 laparoscopic and 20 open-abdominal). They underwent elective abdominal surgery and were randomized to institutional PEEP (4 cm H2O) or electrical impedance tomography–guided PEEP (applied after recruitment maneuvers and targeted at minimizing lung collapse and hyperdistension, simultaneously). Patients were extubated without changing selected PEEP or fractional inspired oxygen tension while under anesthesia and submitted to chest computed tomography after extubation. Our primary goal was to individually identify the electrical impedance tomography–guided PEEP value producing the best compromise of lung collapse and hyperdistention. Results: Electrical impedance tomography–guided PEEP varied markedly across individuals (median, 12 cm H2O; range, 6 to 16 cm H2O; 95% CI, 10–14). Compared with PEEP of 4 cm H2O, patients randomized to the electrical impedance tomography–guided strategy had less postoperative atelectasis (6.2 ± 4.1 vs. 10.8 ± 7.1% of lung tissue mass; P = 0.017) and lower intraoperative driving pressures (mean values during surgery of 8.0 ± 1.7 vs. 11.6 ± 3.8 cm H2O; P < 0.001). The electrical impedance tomography–guided PEEP arm had higher intraoperative oxygenation (435 ± 62 vs. 266 ± 76 mmHg for laparoscopic group; P < 0.001), while presenting equivalent hemodynamics (mean arterial pressure during surgery of 80 ± 14 vs. 78 ± 15 mmHg; P = 0.821). Conclusions: PEEP requirements vary widely among patients receiving protective tidal volumes during anesthesia for abdominal surgery. Individualized PEEP settings could reduce postoperative atelectasis (measured by computed tomography) while improving intraoperative oxygenation and driving pressures, causing minimum side effects.

1 November 2018 in RadioGraphics
Verified
Journal Article
Closed access
AKAsha Kandathil
Asha Kandathil
FKFernando U. Kay
Fernando U. Kay
YBYasmeen M. Butt
Yasmeen M. Butt
JWJason W. Wachsmann
Jason W. Wachsmann
RSRathan M. Subramaniam
Rathan M. Subramaniam
This comprehensive review illustrates the eighth edition of the TNM staging system of lung cancer, highlighting the site-specific strengths and limitations of FDG PET/CT in the staging of non–small cell lung cancer. Lung cancer is the leading cause of cancer-related mortality in the United States, and accurate staging plays a vital role in determining prognosis and treatment. The recently revised eighth edition of the TNM staging system for lung cancer defines new T and M descriptors and updates stage groupings on the basis of substantial differences in survival. There are new T descriptors that are based on the findings at histopathologic examination, and T descriptors are reassigned on the basis of tumor size and extent. No changes were made to the N descriptors in the eighth edition of the TNM staging of lung cancer, because the four N categories that are based on the location of the diseased nodes can be used to consistently predict prognosis. The eighth edition includes a new M1b descriptor for patients with a single extrathoracic metastatic lesion in a single organ (M1b), because they have better survival and different treatment options, compared with those with multiple extrathoracic lesions (M1c). Examination...

1 September 2020 in RadioGraphics
Verified
Journal Article
Closed access
PRPrabhakar Rajiah
Prabhakar Rajiah
APAnushri Parakh
Anushri Parakh
FKFernando U. Kay
Fernando U. Kay
DBDhiraj Baruah
Dhiraj Baruah
AKAvinash R. Kambadakone
Avinash R. Kambadakone
SLShuai Leng
Shuai Leng
By using the differential attenuation of tissues and materials at different x-ray energies, multienergy CT allows distinction of tissues and materials beyond that possible with conventional CT. Multienergy CT involves acquisition of two or more CT measurements with distinct energy spectra. Using the differential attenuation of tissues and materials at different x-ray energies, multienergy...

1 June 2018 in Cardiovascular Diagnosis and Therapy
Verified
Journal Article
Closed access
PDF file
SSSachin S. Saboo
Sachin S. Saboo
MCMurthy Chamarthy
Murthy Chamarthy
SBSanjeev Bhalla
Sanjeev Bhalla
HPHarold Park
Harold Park
PSPatrick Sutphin
Patrick Sutphin
SKSanjeeva P. Kalva
Sanjeeva P. Kalva
Pulmonary arteriovenous malformations (PAVMs) are rare, abnormal low resistance vascular structures that connect a pulmonary artery to a pulmonary vein, thereby bypassing the normal pulmonary capillary bed and resulting in an intrapulmonary right-to-left shunt. The spectrum of PAVMs extends from microscopic lesions causing profound hypoxemia and ground glass appearance on computed tomography (CT) but with normal catheter angiographic findings to classic pulmonary aneurysmal connections that abnormally connect pulmonary veins and arteries. These malformations most commonly are seen in hereditary hemorrhagic telangiectasia (HHT). They are rarely due to secondary conditions such as post congenital heart disease surgery or hepatopulmonary syndrome (HPS). The main complications of PAVM result from intrapulmonary shunt and include stroke, brain abscess, and hypoxemia. Local pulmonary complications include PAVM rupture leading to life-threatening hemoptysis or hemothorax. The preferred screening test for PAVM is transthoracic contrast echocardiography (TTCE). CT has become the gold standard imaging test to establish the presence of PAVM. Endovascular occlusion of the feeding artery is the treatment of choice. Collateralization and recanalization of PAVM following treatment may occur, and hence long term clinical and imaging follow-up is required to assess PAVM enlargement and PAVM reperfusion.

1 October 2017 in Journal of Urology
Verified
Journal Article
Closed access
NCNoah E. Canvasser
Noah E. Canvasser
FKFernando U. Kay
Fernando U. Kay
YXYin Xi
Yin Xi
DPDaniella F. Pinho
Daniella F. Pinho
DCDaniel Costa
Daniel Costa
IPIvan Pedrosa
Ivan Pedrosa
The detection of small renal masses is increasing with the use of cross-sectional imaging, although many incidental lesions have negligible metastatic potential. Among malignant masses clear cell renal cell carcinoma is the most prevalent and aggressive subtype. A method to identify such histology would aid in risk stratification. Our goal was to evaluate a likelihood scale for multiparametric magnetic resonance imaging in the diagnosis of clear cell histology. We retrospectively reviewed the records of patients with cT1a masses who underwent magnetic resonance imaging and partial or radical nephrectomy from December 2011 to July 2015. Seven radiologists with different levels of experience who were blinded to final pathology findings independently reviewed studies based on a predefined algorithm. They applied a clear cell likelihood score, including 1-definitely not, 2-probably not, 3-equivocal, 4-probably and 5-definitely. Binary classification was used to determine the accuracy of clear cell vs all other histologies. Interobserver agreement was calculated with the weighted κ statistic. A total of 110 patients with 121 masses were identified. Mean tumor size was 2.4 cm and 50% of the lesions were clear cell. Defining clear cell as scores of 4 or greater demonstrated 78% sensitivity and 80% specificity while scores of 3 or greater showed 95% sensitivity and 58% specificity. Interobserver agreement was moderate to good with a mean κ of 0.53. A clear cell likelihood score used with magnetic resonance imaging can reasonably identify clear cell histology in small renal masses and may decrease the number of diagnostic renal mass biopsies. Standardization of imaging protocols and reporting criteria is needed to improve interobserver reliability.