Background and Objectives: The standard treatment approach in locally advanced cervical cancer (LACC) is exclusive concurrent chemoradiation therapy (RTCT). The risk of local residual disease after six months from RTCT is about 20–30%. It is directly related to relapse risk and poor survival, such as in patients with recurrent cervical cancer. This systematic review aims to describe studies investigating salvage surgery’s role in persistent/recurrent disease in LACC patients who underwent definitive RTCT. Materials and Methods: Studies were eligible for inclusion when patients had LACC with radiologically suspected or histologically confirmed residual disease after definitive RTCT, diagnosed with post-treatment radiological workup or biopsy. Information on complications after salvage surgery and survival outcomes had to be reported. The methodological quality of the articles was independently assessed by two researchers with the Newcastle–Ottawa scale. Following the recommendations in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement, we systematically searched the PubMed, Scopus, Cochrane, Medline, and Medscape databases in May 2022. We applied no language or geographical restrictions but considered only English studies. We included studies containing data about postoperative complications and survival outcomes. Results: Eleven studies fulfilled the inclusion criteria and all were retrospective observational studies. A total of 601 patients were analyzed concerning the salvage surgery in LACC patients for persistent/recurrent disease after RTCT treatment. Overall, 369 (61.4%) and 232 (38.6%) patients underwent a salvage hysterectomy (extrafascial or radical) and pelvic exenteration (anterior, posterior, or total), respectively. Four hundred and thirty-nine (73%) patients had histologically confirmed the residual disease in the salvage surgical specimen, and 109 patients had positive margins (overall range 0–43% of the patients). The risk of severe (grade ≥ 3) postoperative complications after salvage surgery is 29.8% (range 5–57.5%). After a median follow-up of 38 months, the overall RR was about 32% with an overall death rate of 40% after hysterectomy or pelvic exenteration with or without lymphadenectomy. Conclusions: There is heterogeneity between the studies both in their design and results, therefore the effect of salvage surgery on survival and recurrence cannot be adequately estimated. Future homogeneous studies with an appropriately selected population are needed to analyze the safety and efficacy of salvage hysterectomy or pelvic exenteration in patients with residual tumors after definitive RTCT.
Hereditary women’s syndromes due to inherited mutations result in an elevated risk of developing gynecological cancers over the lifetime of affected carriers. The BRCA 1 and 2 mutations, Lynch syndrome (LS), and mutations in rare hereditary syndromes increase this risk and require more effective management of these patients based on surveillance and prophylactic surgery. Patients need counseling regarding risk-reducing surgery (RRS) and the time required to perform it, considering the adverse effects of premenopausal surgery and the hormonal effect on quality of life, bone density, sexual activity, and cardiological and vascular diseases. Risk-reducing salpingo-oophorectomy (RRSO) is the gold standard for BRCA-mutated patients. An open question is that of endometrial cancer (EC) risk in patients with BRCA1/2 mutation to justify prophylactic hysterectomy during RRSO surgical procedures. RRS provides a 90–95% risk reduction for ovarian and breast cancer in women who are mutation carriers, but the role of prophylactic hysterectomy is underinvestigated in this setting of patients. In this review, we evaluate the management of the most common hereditary syndromes and the benefits of risk-reducing surgery, particularly exploring the role of prophylactic hysterectomy.
Objectives: Sentinel lymph node biopsy is considered a crucial step in endometrial cancer staging. Cervical injection has become the most favored technique and indocyanine green has been demonstrated to be more accurate than other tracers. Different near-infrared camera systems are currently being used to detect indocyanine green in sentinel lymph nodes and have been compared in different patients. The present study aimed to determine the number and site of sentinel lymph nodes detected in the same patients with two different near-infrared technologies. Methods: This is a prospective, single-center, observational, non-sponsored study. Patients with presumed uterine-confined endometrial cancer were prospectively enrolled. After cervical injection, two different near-infrared cameras were used to detect sentinel lymph nodes at the same time: Olympus, Tokyo, Japan—considered the standard (SNIR); and Medtronic, Minneapolis, MN, USA with VISION SENSE® which is a new laser near-infrared (LNIR) fluorescence laparoscope. The two cameras were alternatively switched on to detect sentinel lymph nodes in the same patients. Results: Seventy-four consecutive patients were included in the study. Most of the patients were diagnosed with endometrioid histology (62, 83.8%), FIGO stage IA (48, 64.9%), grade 2 (43, 58.1%), and underwent surgery with laparoscopic approach (70, 94.0%). The bilateral detection rate was 56/74 (75.7%) with SNIR and 63/74 (85.1%) with LNIR (p = 0.214). The total number of sentinel lymph nodes identified in the left hemipelvis was 65 and 70 with SNIR and LNIR, respectively; while in the right hemipelvis, there were 74 and 76, respectively. The median number of sentinel lymph nodes identified with SNIR and LNIR was 2 (range, 0–4) and 2 (range, 0–4), respectively (p = 0.370). No difference in site of sentinel lymph node detection was evident between the two technologies (p = 0.994). Twelve patients (16.2%) had sentinel lymph node metastasis: in all cases metastatic sentinel lymph nodes were detected both with Olympus and LNIR. Conclusions: No difference in bilateral detection rate and number or site of sentinel lymph node detection was evident comparing two different technologies of near-infrared camera for ICG detection in endometrial cancer patients. No difference in sentinel lymph node metastases identification was detected between the two technologies.