Ball bearing failure is one of the major obstacles to the effective operation of large mechanical systems. During maintenance, the initial diagnosis of a fault within the bearing is key to reducing repair costs and improving the efficiency of the system. However, such faults are difficult to accurately diagnose due to noise and the unusual and unpredictable phenomena that they cause in the peaks of the measured signal. In this paper, we present an effective analytical technique for the early diagnosis of ball bearing faults based on vibration data derived from the bearings. We apply a feature extraction technique based on spectral kurtosis (SK) and then filter the results using statistical approaches. The actual defects in the bearings are evaluated in terms of a Gaussian mixture model; principal component analysis is then used to reduce the misclassifications caused by noise and weak fault symptoms. We verified the proposed algorithm experimentally and compared the results of our diagnostic technique to those obtained using the root mean square (rms) of the vibration data to evaluate the performance of the SK-based technique. The rms-based method can only be used to identify defects, whereas the SK-based method can evaluate the level and severity of the fault. In addition, the hybrid statistical SK-based process can diagnose faults without data on the rotational speed, actual load, or design specifications of the bearings or equipment that they are used in.
Flexible capacitive pressure sensors with a simple structure and low power consumption are attracting attention, owing to their wide range of applications in wearable electronic devices. However, it is difficult to manufacture pressure sensors with high sensitivity, wide detection range, and low detection limits. We developed a highly sensitive and flexible capacitive pressure sensor based on the porous Ecoflex, which has an aligned airgap structure and can be manufactured by simply using a mold and a micro-needle. The existence of precisely aligned airgap structures significantly improved the sensor sensitivity compared to other dielectric structures without airgaps. The proposed capacitive pressure sensor with an alignment airgap structure supports a wide range of working pressures (20–100 kPa), quick response time (≈100 ms), high operational stability, and low-pressure detection limit (20 Pa). Moreover, we also studied the application of pulse wave monitoring in wearable sensors, exhibiting excellent performance in wearable devices that detect pulse waves before and after exercise. The proposed pressure sensor is applicable in electronic skin and wearable medical assistive devices owing to its excellent functional features.
18 August 2023 in IEEE Transactions on Transportation Electrification
There is a growing demand for electric vehicles and related technologies to promote low-carbon green growth. To meet this demand, charging technologies that can reduce charging times are becoming increasingly important. However, charging at high C-rates can lead to lithium plating or electrode damage because lithium ions cannot be inserted into the anode while being deposited on the surface, which could increase the irreversible capacity of the battery and pose safety risks. To address this issue, it is necessary to enhance the energy efficiency and safety of batteries, while also suppressing battery deterioration, by increasing the charge transfer and diffusion of lithium ions through thermal management of the battery prior to fast charging. This study analyses the fast charge/discharge characteristics and deterioration factors of cylindrical batteries under different thermal management conditions to establish an optimal thermal management control strategy. The total discharge energy up to the end of life of the battery increases by approximately 266% when the battery is fast charged at a minimum battery cell temperature of 54 °C. Optimal thermal management improves the lithium plating, internal resistance, and Coulombic efficiency during fast charging. Thus, the battery can be safely and efficiently used for an extended period.
6 January 2025 in IEEE Transactions on Industrial Electronics
Electric vehicles (EVs) have gained prominence for addressing global challenges such as climate change and sustainability. With rising EV adoption, there is a growing need for efficient diagnostic methods adaptable to diverse conditions to ensure vehicle reliability and longevity. This study presents a generalized approach to diagnosing degradation and faults in EV battery packs, utilizing real-world driving data to enhance fault detection accuracy. Scaled-down experiments with cylindrical batteries simulated various fault conditions and operational states, enabling the development of a fault diagnosis methodology based on current–voltage profile analysis. This methodology accurately identifies faults, such as external wire harness issues, interconnect busbar anomalies, and individual cell defects, and is adaptable to different battery configurations and environments. Furthermore, a diagnostic technique for battery interconnect systems (BISs) was developed using temperature-compensated resistance calculations from real-world data. Empirical results demonstrate the approach’s effectiveness in detecting and categorizing faults and age-related degradation within EV BISs across various conditions. Notably, we found that a twofold increase in BIS resistance reduces battery efficiency by 1.4% in terms of motor output and raises total energy consumption by 10%. This generalized methodology provides a framework for evaluating BIS performance, enhancing reliability, and optimizing maintenance for diverse EV applications.
Flexible capacitive pressure sensors with a simple structure and low power consumption are attracting attention owing to their wide range of applications in wearable electronic devices. However, it is difficult to manufacture pressure sensors with high sensitivity, wide detection range, and low detection limits. We developed a highly sensitive and flexible capacitive pressure sensor based on the porous Ecoflex, which has an aligned airgap structure and can be manufactured by a simply using a mold and micro-needle. The existence of precisely aligned airgap structures significantly improved the sensor sensitivity compared to other dielectric structures without airgaps. The proposed capacitive pressure sensor with an alignment airgap structure supports a wide range of working pressures (1 Pa – 100 kPa), quick response time (≈100 ms), high operational stability, and low-pressure detection limit (20 Pa). Moreover, we also studied the application of pulse wave monitoring in wearable sensors, exhibiting excellent performance in wearable devices that detect pulse waves before and after exercise. The proposed pressure sensor is applicable in electronic skin and wearable medical assistive devices owing to its excellent functional features.
Faults of mechanical transmission systems generally occur in the rotating bearing part at high speeds, which causes problems such as performance degradation of transmission, generation of noise or vibration, and additional damage to connected adjacent systems. In this way, faults cause adverse effects to the entire system, such as deterioration and damage. The early detection and correction of bearing problems allows for improved system safety and the reduction of maintenance costs, resulting in efficient system operation. As a result, a variety of methods have been developed by many researchers in order to diagnose bearing mechanical defects, and one of the most representative methods is applying various signal processing techniques to vibration data. Wavelet packet transform (WPT) and kurtogram were used in this study to identify the frequency band that contained the fault component, and the enhanced kurtogram technique was used to analyze the fault. A technique for minimizing the effect of intermittent abnormal peak components caused by noise and external influences has been presented using sub-band averaging to detect early fault frequency component detection and fault development. Using the technique proposed in this study, the state of the bearing based on the degree of fault was evaluated quantitatively, and it was demonstrated experimentally that the bearing fault frequency could be detected at an early stage by the filtered data. In a situation where it is difficult to accept all the detailed design specifications and operating conditions of the complex mechanical systems at industrial sites, determining the degree of fault with simple time-series data and detecting fault components at an early stage is a practical analysis technique for fault diagnosis in the industrial field using various rotating bodies.