Irradiation with ultraviolet light (UV) at 254 nm is effective in inactivating a wide range of human pathogens. In Sweden, a UV dose of 400 J/m2 is often used for the treatment of drinking water. To investigate its effect on virus inactivation, enteric viruses with different genomic organizations were irradiated with three UV doses (400, 600, and 1000 J/m2), after which their viability on cell cultures was examined. Adenovirus type 2 (double-stranded DNA), simian rotavirus 11 (double-stranded RNA), and echovirus 30 (single-stranded RNA) were suspended in tap water and pumped into a laboratory-scale Aquada 1 UV reactor. Echovirus 30 was reduced by 3.6-log10 by a UV dose of 400 J/m2. Simian rotavirus 11 and adenovirus type 2 were more UV resistant with only 1-log10 reduction at 400 J/m2 and needed 600 J/m2 for 2.9-log10 and 3.1-log10 reductions, respectively. There was no significant increase in the reduction of viral viability at higher UV doses, which may indicate the presence of UV-resistant viruses. These results show that higher UV doses than those usually used in Swedish drinking water treatment plants should be considered in combination with other barriers to disinfect the water when there is a risk of fecal contamination of the water.
For the microbiological safety of drinking water, disinfection methods are used to remove or inactivate microorganisms. Chlorine and chlorine dioxide are often used as disinfectants in drinking water treatment plants (DWTPs). We investigated the effectiveness of these chemicals in inactivate echovirus 30 (E30), simian 11 rotavirus (RV SA11), and human adenovirus type 2 (HAdV2) in purified water from a DWTP. Within two minutes of contact, chlorine dioxide inactivated E30 by 4-log10, RV SA11 by 3-log10, and HAdV2 could not be detected, while chlorine reduced E30 by 3-log10, RV SA11 by 2–3log10, and HAdV2 by 3–4log10. However, viral genomes could be detected for up to 2 h using qPCR. The CT method, based on a combination of disinfectant concentration and contact time, during such a short initial phase, is problematic. The high concentrations of disinfectant needed to neutralize organic matter may have a strong immediate effect on virus viability. This may lead to the underestimation of disinfection and overdosing of disinfectants in water with organic contamination. These results are useful for the selection of disinfection systems for reuse of treated wastewater and in the risk assessment of water treatment processes using chlorine and chlorine dioxide.
28 October 2025 in Environmental Microbiology Reports
Little is known about virome changes in raw and drinking water over time, and differences between raw water sources and treatment technologies. This study used metagenomics to assess viruses prevalent in raw and drinking water samples over 1 year from six Swedish drinking water treatment plants (DWTPs) with varying treatment barriers and with different raw water sources. Sequences homologous to known viruses in the raw water samples were detected by amplification and next‐generation sequencing and classified into 152 different virus species belonging to 76 virus families/orders. The majority were small bacteriophages. Other viral genomes were homologous to viruses infecting plants, invertebrates, vertebrates, mammals and giant viruses infecting amoeba or algae. Several virus species were simultaneously found in both raw and drinking water, indicating passage through the purification barriers, although reduced by 1–3 log 10 after treatment. Most viruses detected in water samples after ultrafiltration were small viruses, and other barriers appeared more effective at removing smaller viruses. To avoid detecting viruses possibly replicating within DWTPs, viruses were separated according to the possibility that the host could be found in the water sources or not. These results underscore the importance of monitoring both raw and drinking water for small viruses, especially when viral contamination of the source water is at risk, to ensure drinking water quality.