With the rapid development of urbanization and underground transportation, as well as the frequent occurrence of extreme weather conditions such as extreme rainfall, flooding disasters for rail transit are becoming severe, and need to be urgently clarified in terms of the mechanism causing them. In this study, a comprehensive model for water damage at the entrance to a rail transit station is proposed, emphasizing the entire process of extreme weather–surface ponding–underground intrusion. The model is validated by the inundation process of Line 5 of the Zhengzhou Metro during the “7.20” event and further applied to Wanqingsha Station of Guangzhou Metro Line 18 in China to determine the surrounding water depth, distribution, total water inflow volume, and water damage time under different rainfall intensities, rain patterns and protection scenarios. It was found that when rainfall reaches the level of a 1-in-2000-years event, the surface water begins to invade the internal rail transit system through the rail transit entrances. When facing extreme rainfall akin to the “7.20” event in Zhengzhou, the rail transit system in Wanqingsha Station meets a heightened risk of water damage, resulting in significantly deeper water levels compared to 1-in-5000-year rainfall event in Guangzhou and exceeds the height of the subway entrances. Analysis of the water intrusion process reveals that, as rainfall intensity escalates, the total inflow water volume into the rail transit system increases while escape time diminishes. Moreover, under identical rainfall intensity, pre-type rainfall yields the highest total water inflow, whereas mid-type rainfall exhibits the shortest escape time. Enhancing the protection conditions can markedly attenuate surface water intrusion into the subterranean rail transit system, thereby enhancing the evacuation time for individuals within the system.
The mechanical response and deformation characteristics in calcareous sand foundations during pile driving and setup were studied using model tests combined with the technical methods of tactile pressure sensors and close-range photogrammetry. Different types of piles were considered, including a pipe pile, square pile and semi-closed steel pipe pile. The test results show that during pile driving, the pile tip resistance of different piles increases with an increase in the pile insertion depth, and an obvious fluctuation is also obtained due to the particle breakage of the calcareous sand and energy dissipation. Different degrees of particle breakage generated by different type piles make the internal stress variations different, as with the pile tip resistance. The pile tip resistance of model pile A, which simulates a pipe pile, is the highest, followed by model pile B, the simulated square pile. Model pile C, which simulates a semi-closed steel pipe pile, has the smallest pile tip resistance because its particle breakage is the most obvious and the pile tip energy cannot be continuously accumulated. The induced deformation such as sag or uplift on the surface and the associated influence range for the calcareous sand foundation are the smallest for model pile C, followed by model pile B and then model pile A. Model pile A has the most obvious pile driving effect. During the pile setup process after piling, the increase in the total internal stress of model pile B is the largest, and the improvement of the potential bearing capacity is the most obvious, followed by model pile A and model pile C. During the pile setup, the induced uplift deformation in pile driving is recovered and the potential bearing capacity increases due the redistribution and uniformity of the vertical and radial stress distributions in the calcareous sand foundation. Considering the potential bearing capacity of different model piles, the influence range of pile driving, foundation deformation and the pile setup effect, it is suggested to use a pointed square pile corresponding to model pile B in pile engineering in calcareous sand foundations.
The current monitoring methods for tunnel structure deformation mainly focus on laser distance measurement, fiber Bragg grating, photogrammetry, electronic total station, hydrostatic leveling and so on. Compared with traditional monitoring methods, MEMS sensors have the advantages of small size, low cost, low energy consumption and high accuracy. In this paper, MEMS sensors are used for the continuous real-time intelligent monitoring of model tunnels, and the multi-point deployment of MEMS sensors is set up for the tunnel structure monitoring with the indicators of acceleration and inclination. The results demonstrated that β-sample interpolation of the angles of the MEMS measurement points, and then integration of the overall displacements can better reflect the form of uneven settlement of the tunnel. For tunnel models with uneven settlement as the main deformation, the angle interpolation method allows the MEMS sensor to measure the vertical displacement more accurately and to determine the load mode to a certain extent. However, for tunnel models with global settlement as the main deformation, the results vary considerably from reality, as only the uneven part of the settlement can be measured using the angular interpolation method.
Stress-induced anisotropy in calcareous sand can cause an uneven displacement in island reef engineering. In this study, stiffness, as a quantitative indicator, is explored to reveal the stress-induced anisotropy in calcareous sand. Based on the discrete element method, the stiffness anisotropic characteristics of calcareous sand during shearing, as well as the impact of particle breakage, are investigated by numerical simulations. Both the macro and micro responses, i.e., the maximum shear modulus, contact normal, strong and weak contact normal force, and the direction of particle breakage, are explored for calcareous sand with different particle breakage ratios. The results show that calcareous sand exhibits notable anisotropy during shearing, with the maximum shear modulus in the vertical direction (deviatoric stress direction) being significantly greater than that in the horizontal direction. Moreover, the higher the particle breakage rate, the lower the stiffness and its anisotropy. The micro-mechanism results indicate that the primary particle breakage during the shearing process occurs in the vertical direction. That is, the particle breakage weakens the strong contact force in the vertical direction, leading to a redistribution of the strong contact forces from the vertical direction to other directions. This redistribution mainly manifests in a decrease in the anisotropy of contact normal and contact vector within the sample, as well as a decrease in the proportion of strong contact forces in the overall contacts. This, in turn, reduces the shear strength and stiffness of calcareous sand, particularly in the vertical direction, and results in a decrease in the maximum shear modulus and its anisotropy. The maximum reduction can be up to 50% of the original value. These insights can provide a certain theoretical support for the uneven displacement and long-term stability of calcareous sand for islands and reefs.
30 August 2024 in Journal of Ocean Engineering and Marine Energy