Chao Li

Dr. Chao Li

Tencent (China), Shenzhen, Guangdong, China
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WLWen Qian Lin
Wen Qian Lin
CLChao Li
Chao Li
People’s emotions play an important part in our daily life and can not only reflect psychological and physical states, but also play a vital role in people’s communication, cognition and decision-making. Variations in people’s emotions induced by external conditions are accompanied by variations in physiological signals that can be measured and identified. People’s psychological signals are mainly measured with electroencephalograms (EEGs), electrodermal activity (EDA), electrocardiograms (ECGs), electromyography (EMG), pulse waves, etc. EEG signals are a comprehensive embodiment of the operation of numerous neurons in the cerebral cortex and can immediately express brain activity. EDA measures the electrical features of skin through skin conductance response, skin potential, skin conductance level or skin potential response. ECG technology uses an electrocardiograph to record changes in electrical activity in each cardiac cycle of the heart from the body surface. EMG is a technique that uses electronic instruments to evaluate and record the electrical activity of muscles, which is usually referred to as myoelectric activity. EEG, EDA, ECG and EMG have been widely used to recognize and judge people’s emotions in various situations. Different physiological signals have their own characteristics and are suitable for different occasions. Therefore, a review of the research work and application of emotion recognition and judgment based on the four physiological signals mentioned above is offered. The content covers the technologies adopted, the objects of application and the effects achieved. Finally, the application scenarios for different physiological signals are compared, and issues for attention are explored to provide reference and a basis for further investigation.

2 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
TZTang Zhichuan
Tang Zhichuan
SSShouqian Sun
Shouqian Sun
SZSanyuan Zhang
Sanyuan Zhang
YCYumiao Chen
Yumiao Chen
CLChao Li
Chao Li
SCShi Chen
Shi Chen
To recognize the user’s motion intention, brain-machine interfaces (BMI) usually decode movements from cortical activity to control exoskeletons and neuroprostheses for daily activities. The aim of this paper is to investigate whether self-induced variations of the electroencephalogram (EEG) can be useful as control signals for an upper-limb exoskeleton developed by us. A BMI based on event-related desynchronization/synchronization (ERD/ERS) is proposed. In the decoder-training phase, we investigate the offline classification performance of left versus right hand and left hand versus both feet by using motor execution (ME) or motor imagery (MI). The results indicate that the accuracies of ME sessions are higher than those of MI sessions, and left hand versus both feet paradigm achieves a better classification performance, which would be used in the online-control phase. In the online-control phase, the trained decoder is tested in two scenarios (wearing or without wearing the exoskeleton). The MI and ME sessions wearing the exoskeleton achieve mean classification accuracy of 84.29% ± 2.11% and 87.37% ± 3.06%, respectively. The present study demonstrates that the proposed BMI is effective to control the upper-limb exoskeleton, and provides a practical method by non-invasive EEG signal associated with human natural behavior for clinical applications.

23 February 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CLChao Li
Chao Li
XMXin Min
Xin Min
SSShouqian Sun
Shouqian Sun
WLWenqian Lin
Wenqian Lin
TZTang Zhichuan
Tang Zhichuan
Human gait, as a soft biometric, helps to recognize people through their walking. To further improve the recognition performance, we propose a novel video sensor-based gait representation, DeepGait, using deep convolutional features and introduce Joint Bayesian to model view variance. DeepGait is generated by using a pre-trained “very deep” network “D-Net” (VGG-D) without any fine-tuning. For non-view setting, DeepGait outperforms hand-crafted representations (e.g., Gait Energy Image, Frequency-Domain Feature and Gait Flow Image, etc.). Furthermore, for cross-view setting, 256-dimensional DeepGait after PCA significantly outperforms the state-of-the-art methods on the OU-ISR large population (OULP) dataset. The OULP dataset, which includes 4007 subjects, makes our result reliable in a statistically reliable way.

25 August 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XZXianfu Zhang
Xianfu Zhang
SSShouqian Sun
Shouqian Sun
CLChao Li
Chao Li
TZTang Zhichuan
Tang Zhichuan
As lower-limb exoskeleton and prostheses are developed to become smarter and to deploy man–machine collaboration, accurate gait recognition is crucial, as it contributes to the realization of real-time control. Many researchers choose surface electromyogram (sEMG) signals to recognize the gait and control the lower-limb exoskeleton (or prostheses). However, several factors still affect its applicability, of which variation in the loads is an essential one. This study aims to (1) investigate the effect of load variation on gait recognition; and to (2) discuss whether a lower-limb exoskeleton control system trained by sEMG from different loads works well in multi-load applications. In our experiment, 10 male college students were selected to walk on a treadmill at three different speeds (V3 = 3 km/h, V5 = 5 km/h, and V7 = 7 km/h) with four different loads (L0 = 0, L20 = 20%, L30 = 30%, L40 = 40% of body weight, respectively), and 50 gait cycles were performed. Back propagation neural networks (BPNNs) were used for gait recognition, and a support vector machine (SVM) and k-nearest neighbor (k-NN) were used for comparison. The result showed that (1) load variation has significant effects on the accuracy of gait recognition (p < 0.05) under the three speeds when the loads range in L0, L20, L30, or L40, but no significant impact is found when the loads range in L0, L20, or L30. The least significant difference (LSD) post hoc, which can explore all possible pair-wise comparisons of means that comprise a factor using the equivalent of multiple t-tests, reveals that there is a significant difference between the L40 load and the other three loads (L0, L20, L30), but no significant difference was found among the L0, L20, and L30 loads. The total mean accuracy of gait recognition of the intra-loads and inter-loads was 91.81%, and 69.42%, respectively. (2) When the training data was taken from more types of loads, a higher accuracy in gait recognition was obtained at each speed, and the statistical analysis shows that there was a substantial influence for the kinds of loads in the training set on the gait recognition accuracy (p < 0.001). It can be concluded that an exoskeleton (or prosthesis) control system that is trained in a single load or the parts of loads is insufficient in the face of multi-load applications.

20 October 2017
Verified
Book Chapter
Closed access
PDF file
XZXianfu Zhang
Xianfu Zhang
SSShouqian Sun
Shouqian Sun
CLChao Li
Chao Li
XZXiangyu Zhao
Xiangyu Zhao
YHYuping Hu
Yuping Hu

23 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
WLWen Qian Lin
Wen Qian Lin
CLChao Li
Chao Li
YZYunmian Zhang
Yunmian Zhang
In this paper, the interactive application of data gloves based on emotion recognition and judgment system is investigated. A system of emotion recognition and judgment is established based on the set of optimal features of physiological signals, and then a data glove with multi-channel data transmission based on the recognition of hand posture and emotion is constructed. Finally, the system of virtual hand control and a manipulator driven by emotion is built. Five subjects were selected for the test of the above systems. The test results show that the virtual hand and manipulator can be simultaneously controlled by the data glove. In the case that the subjects do not make any hand gesture change, the system can directly control the gesture of the virtual hand by reading the physiological signal of the subject, at which point the gesture control and emotion control can be carried out at the same time. In the test of the manipulator driven by emotion, only the results driven by two emotional trends achieve the desired purpose.