Shiv Govind Singh

Dr. Shiv Govind Singh


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SKSanni Kumar
Sanni Kumar
STSuryasnata Tripathy
Suryasnata Tripathy
AJAnupam Jyoti
Anupam Jyoti
SSShiv Govind Singh
Shiv Govind Singh

16 January 2019 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
SKSrinivasulu Kanaparthi
Srinivasulu Kanaparthi
SSShiv Govind Singh
Shiv Govind Singh

1 February 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
KPK. Brince Paul
K. Brince Paul
VSVikrant Singh
Vikrant Singh
SVSiva Rama Krishna Vanjari
Siva Rama Krishna Vanjari
SSShiv Govind Singh
Shiv Govind Singh

1 April 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
STSuryasnata Tripathy
Suryasnata Tripathy
SVSiva Rama Krishna Vanjari
Siva Rama Krishna Vanjari
VSVikrant Singh
Vikrant Singh
SSS. Swaminathan
S. Swaminathan
SSShiv Govind Singh
Shiv Govind Singh

13 January 2020 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
PSPatta Supraja
Patta Supraja
VSVikrant Singh
Vikrant Singh
SVSiva Rama Krishna Vanjari
Siva Rama Krishna Vanjari
SSShiv Govind Singh
Shiv Govind Singh
In this study we have reported the design and development of a facile, sensitive, selective, and label-free electrochemical sensing platform for the detection of atrazine based on MWCNT-embedded ZnO nanofibers. Electrospun nanofibers were characterized using scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscope (XPS), UV-Visible spectroscope (UV-VIS), and Fourier-transform infrared spectroscope (FTIR). Electrochemical properties of MWCNT-ZnO nanofiber-modified electrodes were assessed using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Binding event of atrazine to anti-atrazine antibody, which immobilized on nanofiber-modified electrode via EDC and NHS chemistry, was transduced with EIS. Due to high conductivity, surface area, and low bandgap of MWCNT-ZnO nanofibers, we have achieved the sensitivity and limit of detection (LoD) of sensor as 21.61 (KΩ μg−1 mL−1) cm−2 and 5.368 zM for a wide detection range of 10 zM–1 µM. The proposed immunosensing platform has good stability, selectivity, repeatability, and reproducibility, and are less prone to interference.

1 June 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
KPK. Brince Paul
K. Brince Paul
SKSanni Kumar
Sanni Kumar
STSuryasnata Tripathy
Suryasnata Tripathy
SVSiva Rama Krishna Vanjari
Siva Rama Krishna Vanjari
VSVikrant Singh
Vikrant Singh
SSShiv Govind Singh
Shiv Govind Singh