The most frequent thyroid cancer is Differentiated Thyroid Cancer (DTC) representing more than 95% of cases. A suitable choice for the treatment of DTC is the systemic administration of 131-sodium or potassium iodide. It is an effective tool used for the irradiation of thyroid remnants, microscopic DTC, other nonresectable or incompletely resectable DTC, or all the cited purposes. Dosimetry represents a valid tool that permits a tailored therapy to be obtained, sparing healthy tissue and so minimizing potential damages to at-risk organs. Absorbed dose represents a reliable indicator of biological response due to its correlation to tissue irradiation effects. The present paper aims to focus attention on iodine therapy for DTC treatment and has developed due to the urgent need for standardization in procedures, since no unique approaches are available. This review aims to summarize new proposals for a dosimetry-based therapy and so explore new alternatives that could provide the possibility to achieve more tailored therapies, minimizing the possible side effects of radioiodine therapy for Differentiated Thyroid Cancer.
This recommendation by the Italian Associations of Nuclear Medicine (AIMN) and Medical Physics (AIFM) focuses on the dosimetric optimization of Nuclear Medicine Therapy (NMT) as clearly requested by the article 56 of the EURATOM Directive 2013/59 and its consequent implementation in article 158 in the Italian Law n. 101/2020. However, this statement must deal with scientific and methodological limits that still exist and, above all, with the currently available limited resources. This paper addresses these specific issues. It distinguishes among many possible kinds of NMT. For each type, dosimetric optimization is recommended or considered optional, according to the general criteria adopted in any human choice, i.e. a check of technical feasibility first, followed by a cost/benefit argument. The classification of therapies as standardized or non-standardized is presented. This is based on the complexity of the type of pathology, on the variability of the treatment outcome, and on the risks involved. According to the present document, which was officially delivered to Italian Health Ministry as necessary interpretation of the law, a therapeutic team can, in science and consciousness, overcome the indications of posology, to optimize and tailoring a treatment with dosimetry, on the basis of published national or international data or guidelines, without need of an Ethics Committee approval. Data collected in this way will provide additional evidence about optimal dosimetric reference values. As conclusion, a formal appeal is made to the European and National regulatory agencies for pharmaceuticals to obtain the official acknowledgment of this principle.
The aim was the validation of a platform for internal dosimetry, named MCID, based on patient-specific images and direct Monte Carlo (MC) simulations, for radioembolization of liver tumors with 90Y-labeled microspheres. CT of real patients were used to create voxelized phantoms with different density and activity maps. SPECT acquisitions were simulated by the SIMIND MC code. Input macros for the GATE/Geant4 code were generated by MCID, loading coregistered morphological and functional images and performing image segmentation. The dosimetric results obtained from the direct MC simulations and from conventional MIRD approach at both organ and voxel level, in condition of homogeneous tissues, were compared, obtaining differences of about 0.3% and within 3%, respectively, whereas differences increased (up to 14%) introducing tissue heterogeneities in phantoms. Mean absorbed dose for spherical regions of different sizes (10 mm ≤ r ≤ 30 mm) from MC code and from OLINDA/EXM were also compared obtaining differences varying in the range 7–69%, which decreased to 2–9% after correcting for partial volume effects (PVEs) from imaging, confirming that differences were mostly due to PVEs, even though a still high difference for the smallest sphere suggested possible source description mismatching. This study validated the MCID platform, which allows the fast implementation of a patient-specific GATE simulation, avoiding complex and time-consuming manual coding. It also points out the relevance of personalized dosimetry, accounting for inhomogeneities, in order to avoid absorbed dose misestimations.
19 May 2015 in Computational and Mathematical Methods in Medicine
Objective. The aim of this work was to assess robustness and reliability of an adaptive thresholding algorithm for the biological target volume estimation incorporating reconstruction parameters. Method. In a multicenter study, a phantom with spheres of different diameters (6.557.4mm) was filled with 18F-FDG at different target-to-background ratios (TBR: 2.570) and scanned for different acquisition periods (25min). Image reconstruction algorithms were used varying number of iterations and postreconstruction transaxial smoothing. Optimal thresholds (TS) for volume estimation were determined as percentage of the maximum intensity in the cross section area of the spheres. Multiple regression techniques were used to identify relevant predictors of TS. Results. The goodness of the model fit was high (R2: 0.740.92). TBR was the most significant predictor of TS. For all scanners, except the Gemini scanners, FWHM was an independent predictor of TS. Significant differences were observed between scanners of different models, but not between different scanners of the same model. The shrinkage on cross validation was small and indicative of excellent reliability of model estimation. Conclusions. Incorporation of postreconstruction filtering FWHM in an adaptive thresholding algorithm for the BTV estimation allows obtaining a robust and reliable method to be applied to a variety of different scanners, without scanner-specific individual calibration.
Purpose: A high level of personalization in Molecular Radiotherapy (MRT) could bring advantages in terms of treatment effectiveness and toxicity reduction. Individual organ‐level dosimetry is crucial to describe the radiopharmaceutical biodistribution expressed by the patient, to estimate absorbed doses to normal organs and target tissue(s). This paper presents a proof‐of‐concept Monte Carlo simulation study of “WIDMApp” (Wearable Individual Dose Monitoring Apparatus), a multi‐channel radiation detector and data processing system for in vivo patient measurement and collection of radiopharmaceutical biokinetic data (i.e., time‐activity data). Potentially, such a system can increase the amount of such data that can be collected while reducing the need to derive it via nuclear medicine imaging.Methods: a male anthropomorphic MIRD phantom was used to simulate photons (i.e., gamma‐rays) propagation in a patient undergoing aI thyroid treatment. The administered activity was set to the amount usually administered for the treatment of differentiated carcinoma while its initial distribution in different organs was assigned following the ICRP indications for theI biokinetics. Using this information, the simulation computes the Time‐dependent Counts Curves (TCCs) that would have been measured by seven WIDMApp‐like sensors placed and oriented to face each one of five emitting organs plus two thyroid lobes. A deconvolution algorithm was then applied on this simulated data set to reconstruct the Time‐Activity Curve (TAC) of each organ. Deviations of the reconstructed TACs parameters from values used to generate them were studied as a function of the deconvolution algorithm initialization parameters and assuming non‐Poisson fluctuation of the TCCs data points.Results: This study demonstrates that it is possible, at least in the simple simulated scenario, to reconstruct the organ cumulated activity by measuring the time dependence of counts recorded by several detectors placed at selected positions on the patient's body. The ability to perform in vivo sampling more frequently than conventional biokinetic studies increases the number of time points and therefore the accuracy in TAC estimates. In this study, an accuracy on cumulated activity of 5% is obtained even with a 20% error on the TCC data points and a 50% error on the initial guess on the parameters of the deconvolution algorithm.Conclusions: the WIDMApp approach could provide an effective tool to characterize more accurately the radiopharmaceutical biokinetics in MRT patients, reducing the need of resources of nuclear medicine departments, such as technologist and scanner time, to perform individualized biokinetics studies. The relatively simple hardware for the approach proposed would allow its application to large numbers of patients. The results obtained justify development of an actual prototype system to characterize this technique under realistic conditions.