Chaimongkon Peampring

Dr. Chaimongkon Peampring

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2022 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
KCKanyakorn Charoenphol
Kanyakorn Charoenphol
CPChaimongkon Peampring
Chaimongkon Peampring
Objective Digital complete denture fabrication can be accomplished by either milling or three-dimensional (3D)-printing approach in which minimal distortion during processing contributes to effective denture base adaption, which leads to good denture retention. The purpose of this study was to compare the fit accuracy of milled and 3D-printed complete denture bases. Materials and Methods The reference edentulous maxillary arch model was scanned to generate virtual denture bases using computer-aided manufacturing software that exports as standard tessellation language files. Denture bases were constructed using a milling and 3D-printing technique using digital light processing method (n = 10). Intaglio surfaces of denture bases were scanned and superimposed on the reference model. The fit accuracy was quantified as root mean square error and evaluated statistically using independent t-test comparisons with a significance level of 0.05. Results Milled denture bases were significantly more accurate in adaptation than 3D-printed dentures in the overall intaglio area and primary bearing area of denture bases. 3D-printed denture bases demonstrated significantly greater accuracy in adaptation than milled denture bases in the peripheral/posterior palatal seal area. Conclusion Milled denture bases fit better in the overall and primary stress-bearing areas than 3D-printed dentures, while 3D-printed dentures appeared more accurate in the peripheral seal area, which had a minor undercut that is not suitable for using milling technology.

18 August 2022 in Molecules
Verified
Journal Article
Open access
PDF file
SKSuchada Kongkiatkamon
Suchada Kongkiatkamon
CPChaimongkon Peampring
Chaimongkon Peampring
Translucent zirconia is becoming the material of choice for the esthetic restorative material. We aimed to evaluate the surface structure, phase determination, translucency, and flexural strength of 5Y-TZP Zirconia (Katana STML Block and Disc) between the regular sintering and the speed sintering with and without low-temperature degradation (LTD). A total of 60 zirconia discs (30 per group; regular sintering and speed sintering) were used in this study. A CAM machine was used to mill cylinders out of the zirconia blanks and then cut into smaller discs. For the speed sintering, the zirconia blocks were milled into smaller discs. The zirconia discs were subjected to regular and speed sintering with and without LTD. Scanning electron microscopy was used to characterize the zirconia specimens and the zirconia grain size. Furthermore, the zirconia specimens were analyzed for elemental analysis using energy dispersive spectroscopy and phase identification using X-ray diffraction. The zirconia specimens were subjected to translucency measurements and biaxial flexural strength testing. The results of the zirconia specimens were compared among the groups. Statistical analysis was completed using SPSS version 20.0 to detect the statistically significant differences (p value = 0.05). A one-way ANOVA with multiple comparisons was performed using Scheffe analysis among the groups. The speed sintering presented smaller grain sizes. The zirconia specimens with and without LTD in regular and speed sintering presented a similar surface structure. Regular sintering showed more translucency compared to speed sintering. Multiple comparisons of the translucency parameter were a significant difference (p value < 0.05) between the various groups except for the comparison between speed sintering and speed sintering LTD. The regular sintering showed bigger gain sizes and slightly more translucency compared to speed sintering. The speed sintering showed higher biaxial flexural strengths compared to regular sintering. This shows that speed sintering can be considered a suitable method of sintering zirconia.

1 January 2020 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
SKSantiphab Kengtanyakich
Santiphab Kengtanyakich
CPChaimongkon Peampring
Chaimongkon Peampring
Kengtanyakich S, et al. J Adv Prosthodont. 2020 Oct;12(5):265-272. https://doi.org/10.4047/jap.2020.12.5.265

1 January 2014 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
CPChaimongkon Peampring
Chaimongkon Peampring
Peampring C. J Adv Prosthodont. 2014 Oct;6(5):423-426. https://doi.org/10.4047/jap.2014.6.5.423

Verified
Journal Article
Open access
PDF file
SKSuchada Kongkiatkamon
Suchada Kongkiatkamon
CPChaimongkon Peampring
Chaimongkon Peampring
Background: Although there are a few studies which compare fast and slow sintering in normal zirconia crowns, it is essential to compare the cracks and load-bearing capacity in zirconia screw-retained implant crowns between regular and speed sintering protocols. This research aimed to compare the surface structure, cracks, and load-bearing capacity in zirconia screw-retained implant crowns between regular sintering (RS) and speed sintering (SS) protocol with and without cyclic loading (fatigue). Methods: A total of 60 screw-retained crowns were fabricated from zirconia (Katana STML Block) by the CAD/CAM system. Then, 30 crowns were subjected to the RS protocol and 30 crowns were subjected to the SS protocol. Cyclic loading was done in half zirconia crowns (15 crowns in each group) using a chewing simulator CS-4.8/CS-4.4 at room temperature. The loading force was applied on the middle of the crowns by a metal stylus underwater at room temperature with a chewing simulator at an axial 50 N load for 240,000 cycles and lateral movement at 2 mm. Scanning electron microscopy was done to study the surface of the crowns and the cracks in the crowns of the regular and speed sintering protocols, with and without fatigue. Results: For the speed sintering group, the surface looks more uniform, and the crack lines are present at a short distance compared to regular sintering. The sintering protocol with a larger Weibull module and durability increases the reliability. It showed that the Speed group showed the maximum fracture load, followed by the regular, speed fatigue, and regular fatigue groups. The fracture load in various groups showed significant differences. Conclusions: It was found that the speed group showed the maximum fracture load followed by the regular, speed fatigue, and regular fatigue. The crack lines ran from occlusal to bottoms (gingiva) and the arrest lines were perpendicular to the crack propagations.

10 December 2021 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
CPChaimongkon Peampring
Chaimongkon Peampring
SKSantiphab Kengtanyakich
Santiphab Kengtanyakich
Objective This study investigated the effect of hydrothermal aging on surface roughness and translucency of various translucent zirconia materials.Materials and Methods Four types of zirconia were tested. Group 1 was translucent zirconia with no cubic structure. Group 2, 3, and 4 included cubic-containing zirconia with different amounts of cubic structures (less than 30%, 30–50%, and more than 50%, respectively). Each group contained 15 disk-shape specimens with dimensions of 15 mm in diameter and 1 mm in thickness. As-sintered surface roughness, translucency parameter, and contrast ratio were evaluated in the two different sessions, before and after aging.Statistical Analysis Two-way repeated measures ANOVA with Bonferroni test was used to analyze statistically significant difference in those tested parameters. Phase structure before and after aging was analyzed by X-ray diffraction analysis (XRD).Results Groups 1 and 2 showed significant increased surface roughness after aging while groups 3 and 4 showed no alteration of surface. There was no effect of aging on translucency in all groups. After aging, group 1 and 2 presented monoclinic structure (16.63 and 5.01%, respectively).Conclusion Hydrothermal aging caused phase transformation and increasing surface roughness in group 1 and 2 but did not affect translucency in all groups.