Sergiu Marian Cazacu

Prof. Dr. Sergiu Marian Cazacu

Gastroenterology, University of Medicine and Pharmacy of Craiova, Craiova, Dolj, Romania
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in Journal of Inflammation Research
Verified
Journal Article
Open access
PDF file
SCSergiu Marian Cazacu
Sergiu Marian Cazacu
MPMircea Parscoveanu
Mircea Parscoveanu
DCDan Cartu
Dan Cartu
EMEmil Moraru
Emil Moraru
IRIon Rogoveanu
Ion Rogoveanu
MDManuela Iuliana Dragomir
Manuela Iuliana Dragomir
Introduction: The neutrophil–lymphocyte ratio (NLR) has been suggested as a reliable marker for predicting inflammation progression and severity of acute pancreatitis, although the role of the NLR stratified by etiology is still insufficiently studied. However, the NLR’s role in mortality prediction was poorly evaluated in the literature. Patients and Methods: We performed a retrospective, cross-sectional study to analyze the role of NLR0 (at admission) and NLR48 (at 48 hours) in acute pancreatitis as compared with CRP, BISAP, SOFA, and modified CTSI (mCTSI) for the prediction of mortality and severe acute pancreatitis (SAP) in patients admitted into the Emergency Clinical County Hospital of Craiova during 48 months. The primary assessed outcomes were the rate of in-hospital mortality, the rate of persistent organ failure, and ICU admissions. We analyzed mortality prediction for all acute pancreatitis, for biliary, alcoholic, and hypertriglyceridemic acute pancreatitis, for severe forms, and for patients admitted to the ICU. Results: A total of 725 patients were selected; 42.4% had biliary acute pancreatitis, 27.7% had alcoholic acute pancreatitis, and 8.7% had hypertriglyceridemia-induced acute pancreatitis. A total of 13.6% had POF during admission. The AUC for NLR48 in predicting mortality risk and SAP was 0.81 and 0.785, superior to NLR0, CRP48, and mCTSI but inferior to BISAP and SOFA scores. The NLR48/NLR0 ratio did not add significantly to the accuracy. NLR0 and NLR48 performed poorly for mortality prediction in severe forms and in patients admitted to the ICU. NLR48 has good accuracy in our study for predicting death risk in biliary and alcoholic acute pancreatitis but not in hypertriglyceridemic acute pancreatitis. Conclusion: NLR48 was a good indicator in predicting mortality risk and severe forms in all patients with acute pancreatitis, but not of death in SAP and in patients admitted to ICU, with good accuracy for predicting death risk in biliary and alcoholic acute pancreatitis but not in hypertriglyceridemic acute pancreatitis.

5 November 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Cristiana Marinela UrhutCristiana Marinela Urhut
Cristiana Marinela Urhut
DSDaniela Larisa D Sandulescu
Daniela Larisa D Sandulescu
Costin Teodor StrebaCostin Teodor Streba
Costin Teodor Streba
MMMădălin Mămuleanu
Mădălin Mămuleanu
ACAdriana Ciocalteu
Adriana Ciocalteu
SDSuzana Dǎnoiu
Suzana Dǎnoiu
Contrast-enhanced ultrasound (CEUS) is widely used in the characterization of liver tumors; however, the evaluation of perfusion patterns using CEUS has a subjective character. This study aims to evaluate the accuracy of an automated method based on CEUS for classifying liver lesions and to compare its performance with that of two experienced clinicians. The system used for automatic classification is based on artificial intelligence (AI) algorithms. For an interpretation close to the clinical setting, both clinicians knew which patients were at high risk for hepatocellular carcinoma (HCC), but only one was aware of all the clinical data. In total, 49 patients with 59 liver tumors were included. For the benign and malignant classification, the AI model outperformed both clinicians in terms of specificity (100% vs. 93.33%); still, the sensitivity was lower (74% vs. 93.18% vs. 90.91%). In the second stage of multiclass diagnosis, the automatic model achieved a diagnostic accuracy of 69.93% for HCC and 89.15% for liver metastases. Readers demonstrated greater diagnostic accuracy for HCC (83.05% and 79.66%) and liver metastases (94.92% and 96.61%) compared to the AI system; however, both were experienced sonographers. The AI model could potentially assist and guide less-experienced clinicians to discriminate malignant from benign liver tumors with high accuracy and specificity.

21 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SCSergiu Marian Cazacu
Sergiu Marian Cazacu
DADragos Ovidiu Alexandru
Dragos Ovidiu Alexandru
RSRăzvan-Cristian Statie
Răzvan-Cristian Statie
SISevastita Iordache
Sevastita Iordache
Bogdan Silviu UngureanuBogdan Silviu Ungureanu
Bogdan Silviu Ungureanu
MFMirela Marinela Florescu
Mirela Marinela Florescu
(1) Background: The assessment of mortality and rebleeding rate in upper gastrointestinal bleeding (UGIB) is essential, and several prognostic scores have been proposed. Some patients with UGIB did not undergo endoscopy, either because they refused the procedure, suffered from alcohol withdrawal symptoms or altered general status, or because the bleeding was severe enough to cause death before the endoscopy. The mortality risk in the subgroup of patients without endoscopy is poorly evaluated in the literature. (2) Methods: The purpose of the study was to identify the most useful scores for the assessment of in-hospital mortality in patients with UGIB with no endoscopy performed and no known etiology. A total of 198 patients with UGIB and no endoscopy performed were admitted between January 2017 and December 2021 and the accuracy of 12 prognostic scores and the Charlson comorbidity index for in-hospital mortality prediction were analyzed, as well as Child–Pugh Turcotte (CPT) and Meld scores in patients with cirrhosis. (3) Results: The mortality rate was 37.9%, higher than in variceal (21.9%, p < 0.0001) and non-variceal bleeding (7.4%, p < 0.0001). The most accurate scores by AUC were the International Bleeding score (INBS, 0.844), Glasgow Blatchford (0.783), MAP score (0.78), Iino (0.766), AIM65 and modified N-score (0.745 each), modified Glasgow-Blatchford (0.73), H3B2 and N-score (0.701); Rockall, Baylor, and T-score had an AUC below 0.7. MELD score was superior to CPT in patients with cirrhosis (AUC 0.811 versus 0.670). (4) Conclusions: The mortality rate in UGIB with no endoscopy was higher than in both variceal and non-variceal bleeding and was higher in the pandemic period but with no statistical significance (45.3% versus 32.14%, p = 0.0586), mainly because of positive cases. Only one case of rebleeding was noted; the hospitalization period was significantly shorter. The most accurate score was International Bleeding Score; the MELD score had a higher but moderate accuracy compared with CPT in patients with cirrhosis.

23 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Cristiana Marinela UrhutCristiana Marinela Urhut
Cristiana Marinela Urhut
DSDaniela Larisa D Sandulescu
Daniela Larisa D Sandulescu
ACAdriana Ciocalteu
Adriana Ciocalteu
SCSergiu Marian Cazacu
Sergiu Marian Cazacu
SDSuzana Dǎnoiu
Suzana Dǎnoiu
Recent advances in the field of ultrasonography offer promising tools for the evaluation of liver tumors. We aim to assess the value of multimodal ultrasound in differentiating hepatocellular carcinomas (HCCs) from other liver lesions. We prospectively included 66 patients with 72 liver tumors. The histological analysis was the reference standard for the diagnosis of malignant liver lesions, and partially for benign tumors. All liver lesions were assessed by multiparametric ultrasound: standard ultrasound, contrast-enhanced ultrasound (CEUS), the point shear wave elastography (pSWE) using shear wave measurement (SWM) method and real-time tissue elastography (RTE). To diagnose HCCs, CEUS achieved a sensitivity, specificity, accuracy and positive predictive value (PPV) of 69.05%, 92.86%, 78.57% and 93.55%, respectively. The mean shear-wave velocity (Vs) value in HCCs was 1.59 ± 0.29 m/s, which was lower than non-HCC malignancies (p < 0.05). Using a cut-off value of 1.58 m/s, SWM achieved a sensitivity of 54.76%, and 82.35% specificity, for differentiating HCCs from other malignant lesions. The combination of SWM and CEUS showed higher sensitivity (79.55%) compared with each technique alone, while maintaining a high specificity (89.29%). In RTE, most HCCs (61.53%) had a mosaic pattern with dominant blue areas corresponding to type “c” elasticity. Elasticity type “c” was 70.59% predictive for HCCs. In conclusion, combining B-mode ultrasound, CEUS, pSWE and RTE can provide complementary diagnostic information and potentially decrease the requirements for other imaging modalities.

18 November 2022 in Journal of Multidisciplinary Healthcare
Verified
Journal Article
Open access
PDF file
PPPetrica Popa
Petrica Popa
SISevastita Iordache
Sevastita Iordache
DFDan Nicolae Florescu
Dan Nicolae Florescu
VIVlad Florin Iovanescu
Vlad Florin Iovanescu
AVAlexandru Vieru
Alexandru Vieru
SCSergiu Marian Cazacu
Sergiu Marian Cazacu
Introduction: During the last few years, a progressive higher proportion of patients have had upper gastrointestinal bleeding (UGIB) related to antithrombotic therapy. The introduction of direct oral anticoagulant (DOAC) and COVID-19 pandemic may change the incidence, mortality, and follow-up, especially in patients at high risk of bleeding. Patients and Methods: We studied the use of anti-thrombotic therapy (AT) in patients with upper gastrointestinal bleeding for 5 years (January 2017–December 2021) including Covid-19 pandemic period (March 2020–December 2021). We analyzed mortality rate, rebleeding rate and need for transfusion in patients with AT therapy compared with those without AT therapy and risk factors for mortality, and also the incidence of gastrointestinal bleeding in patients admitted for COVID-19 infection. Results: A total of 824 patients were admitted during Covid-19 pandemic period and 1631 before pandemic period; a total of 426 cases of bleeding were recorded in patients taking antithrombotic therapy and the frequency of antithrombotic therapy in patients with UGIB was higher in pandemic period (24.39% versus 13.8%). Unadjusted mortality was 12.21%, similar with patients with no antithrombotic treatment but age-adjusted mortality was 9.62% (28% lower). The rate of endoscopy was similar but fewer therapeutic procedures were required. Mean Hb level was 10% lower, and more than 60% of patients required blood transfusion. Conclusion: Mortality was similar compared with patients with no antithrombotic therapy, fewer therapeutic endoscopies were performed and similar rebleeding rate and emergency surgery were noted. Hb level was 10% lower and a higher proportion of patients required blood transfusions. Mortality was higher in DOAC treatment group compared with VKA patients but with no statistical significance. The rate of upper gastrointestinal bleeding in Covid-19 positive hospitalized cases was 0.58%. The mortality risk in multivariate analysis was associated with GB score, with no endoscopy performed, with obscure and variceal bleeding and with LMWH versus VKA therapy.

29 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
ACAdriana Ciocalteu
Adriana Ciocalteu
SISevastita Iordache
Sevastita Iordache
SCSergiu Marian Cazacu
Sergiu Marian Cazacu
Cristiana Marinela UrhutCristiana Marinela Urhut
Cristiana Marinela Urhut
SSSarmis Marian Sandulescu
Sarmis Marian Sandulescu
DSDaniela Larisa D Sandulescu
Daniela Larisa D Sandulescu
Clinical utility of ancillary features (AFs) in contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS®) is yet to be established. In this study, we assessed the diagnostic yield of CEUS LI-RADS and AFs in hepatocellular carcinoma (HCC). We retrospectively included patients with risk factors for HCC and newly diagnosed focal liver lesions (FLL). All lesions have been categorized according to the CEUS LI-RADS v2017 by an experienced sonographer blinded to clinical data and to the final diagnosis. From a total of 143 patients with 191 FLL, AFs favoring HCC were observed in 19.8% cases as hypoechoic rim and in 16.7% cases as nodule-in nodule architecture. From the total of 141 HCC cases, 83.6% were correctly classified: 57.4%- LR-5 and 26.2%- LR-4. In 9.21% cases, CEUS indicated LR-M; 2.12% cases- LR-3. The LR-5 category was 96.2% predictive (PPV) of HCC. LR-5 had 60.4% sensitivity and 93.6% specificity. PPV for primitive malignancy (LR-4 + LR-5) was 95.7%, with 88% sensitivity, 89.3% specificity and 88.4% accuracy for HCC. LR-4 category had 94.8% PPV and 26.2% sensitivity. CEUS LR4 + LR5 had 81,8% sensitivity for HCCs over 2 cm and 78.57% sensitivity for smaller HCCs. CEUS LR-5 remains an excellent diagnostic tool for HCC, despite the size of the lesion. The use of AFs might improve the overarching goal of LR-5 + LR-4 diagnosis of high specificity for HCC and exclusion of non-HCC malignancy.