Changda Xing

Mr. Changda Xing


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
ZYZhihao Yu
Zhihao Yu
LZLibin Zeng
Libin Zeng
CXChangda Xing
Changda Xing
LSLituo Shang
Lituo Shang
XYXiuyue Yan
Xiuyue Yan
JLJingyu Li
Jingyu Li
In high-precision Hemispherical Resonator Gyroscope (HRG) control systems, readout circuit noise critically determines resonator displacement detection precision. Addressing noise issues, this paper compares the noise characteristics and contribution mechanisms of the Transimpedance Amplifier (TIA) and Charge-Sensitive Amplifier (CSA). By establishing a noise model and analyzing circuit bandwidth, the dominant role of feedback resistor thermal noise in the TIA is revealed. These analyses further demonstrate the significant suppression of high-frequency noise by the CSA capacitive feedback network. Simulation and experimental results demonstrate that the measured noise of the TIA and CSA is consistent with the theoretical model. The TIA output noise is 25.8 μVrms, with feedback resistor thermal noise accounting for 99.8%, while CSA output noise is reduced to 13.2 μVrms, a reduction of 48.8%. Near resonant frequency, the equivalent displacement noise of the CSA is 1.69×10−14m/Hz, a reduction of 86.7% compared to the TIA’s 1.27×10−13m/Hz, indicating the CSA is more suitable for high-precision applications. This research provides theoretical guidance and technical references for the topological selection and parameter design of HRG readout circuits.

3 August 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
CXChangda Xing
Changda Xing
XWXinning Wang
Xinning Wang
ZWZishuo Wang
Zishuo Wang
YWYuchen Wang
Yuchen Wang
CLChong Li
Chong Li
During in-run mode matching under a dual-mode gyro scheme, the stability of the closed-loop control system has a boundary. This phenomenon will lead to the failure of the in-run frequency split calibration scheme when the initial mode mismatch is too severe to exceed the stability boundary. This paper gives a detailed analysis of this stability boundary through simulations and experiments. Results show that the length of the stable region will be affected by the resonant frequency and the Q value. High resonant frequency and low Q value will widen the stable region, but also reduce the sensitivity and rapidity of the calibration. In order to remove the limitation of the stability boundary while applying the in-run frequency split calibration under dual-mode architecture, this paper proposes an enhanced solution that combines both the dual-mode scheme and technology of mode switching. The application of mode switching achieves a pre-calibration of frequency split before the normal gyro operation. This solution is implemented in engineering on a hybrid gyro interface circuit prototype with single-mode and dual-mode. Validation experiments confirmed the effectiveness of this solution.