Liming Chen

Dr. Liming Chen

ZhongShan Ophthalmic Center Sun Yat-sen University, Guangzhou, Guangdong, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YYYe Yiming
Ye Yiming
CXChen Xi
Chen Xi
YHYao Huan
Yao Huan
LCLiming Chen
Liming Chen
YNYu Na
Yu Na
KYKeming Yu
Keming Yu
Purpose: To investigate the ciliary body anatomy and position of the implantable collamer lens (ICL) in low-vault eyes and analyze factors related to insufficient vault. Setting: Zhongshan Ophthalmic Center, Guangzhou, China. Design: Retrospective case–control observational study. Methods: In this study, 73 eyes of 73 patients with an insufficient vault (<250 μm) were matched with 73 eyes with an ideal vault (250 to 750 μm). Ultrasound biomicroscopy was used to determine the ciliary body morphology and ICL position. The biometric parameters acquired by Scheimpflug tomography were compared. The correlation between the vault and these factors was analyzed, and the least absolute shrinkage and selection operator method was used to screen the risk factors for low vault. Results: The low-vault group had a steeper corneal curvature, thicker lens thickness (LT), higher crystalline lens rise, and shorter axial length (AL) (all P < .005). The ciliary process length (CPL) and maximum ciliary body thickness (CBTmax) were significantly smaller, and the trabecular–ciliary angle (TCA), iris–ciliary angle (ICA), and ciliary sulcus width (CSW) were significantly greater in the low-vault eyes (all P < .005). The low-vault group had more ICL haptics below the ciliary process, and TCA, ICA, CPL, CBTmax, CSW, and haptic position were related to the postoperative vault (all P < .05). CPL, AL, and LT were identified as predictors of a low vault. Conclusions: Malposition of ICL haptics behind the ciliary process is a risk factor for low vault. A shorter CPL, thicker LT, and shorter AL are significant risk factors for the postoperative low vault.

21 April 2020 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
CZChengguo Zuo
Chengguo Zuo
BLBing Long
Bing Long
XGXinxing Guo
Xinxing Guo
LCLiming Chen
Liming Chen
XLXing Liu
Xing Liu
Purpose. To evaluate the effect of phacoemulsification and intraocular lens (IOLs) implantation in eyes with medically uncontrolled primary angle-closure glaucoma (PACG) previously treated with trabeculectomy and to quantify the anatomical changes in the anterior chamber angle by ultrasound biomicroscopy (UBM). Methods. Forty-four eyes of 37 consecutive patients with medically uncontrolled PACG coexisting cataracts with a surgical history of trabeculectomy were included in this study. Each patient underwent phacoemulsification and IOL implantation. Indentation gonioscopy and UBM were performed preoperatively and then again 3 months after surgery. The main outcome measures were best-corrected visual acuity (BCVA), intraocular pressure (IOP), number of antiglaucoma medications and anatomical changes in the anterior chamber angle. Results. The mean logarithm of the minimum angle of resolution BCVA significantly improved from 0.52 ± 0.30 preoperatively to 0.26 ± 0.23 postoperatively (p<0.001). The mean IOP significantly decreased from 24.33 ± 9.65 mmHg preoperatively to 18.04 ± 7.86 mmHg postoperatively (p<0.05). 001). The median number of antiglaucoma medications decreased from 2 preoperatively to 1 postoperatively (p<0.001). There was no significant difference in the extent of peripheral anterior synechia after the surgery (p>0.05). Some parameters, including anterior central chamber depth, angle opening distance at 500 μm, trabecular-iris angle, and scleral ciliary process angle, were significantly higher after than before surgery (p<0.001). However, the crystalline lens rise was significantly smaller following the surgery (p<0.001). Conclusions. Phacoemulsification and IOL implantation reduced the IOP and improved vision in eyes with medically uncontrolled filtered PACG. The mechanism underlying the outcomes observed following surgery might be related to the anterior chamber deepening, widened drainage angle, and improved aqueous fluid flow to the trabecular meshwork.

Verified
Journal Article
Open access
PDF file
JRJiawei Ren
Jiawei Ren
XGXinbo Gao
Xinbo Gao
LCLiming Chen
Liming Chen
HLHuishan Lin
Huishan Lin
YLYao Liu
Yao Liu
MLMingkai Lin
Mingkai Lin
Background: The imaging and analysis of the ciliary body (CB) are valuable in many potential clinical applications. This study aims to demonstrate the anatomy characteristics of CB using radial and transverse imaging of ultrasound biometric microscopy (UBM) in healthy Chinese subjects, and to explore the determining factors. Methods: Fifty-four eyes of 30 healthy Chinese subjects were evaluated. Clinical data, including age, body mass index (BMI), intraocular pressure (IOP), axial length (AL), and lens thickness (LT), were collected. Radial and transverse UBM measurements of the ciliary body were performed. Anterior chamber depth (ACD), ciliary sulcus diameter (CSD), ciliary process length (CPL), ciliary process density (CPD), ciliary process area (CPA), ciliary muscle area (CMA), ciliary body area (CBA), ciliary body thickness (CBT0, CBT1, and CBTmax), anterior placement of ciliary body (APCB), and trabecular-ciliary angle (TCA) of four (superior, nasal, inferior, and temporal) quadrants were measured. Results: The average CPL was 0.513 ± 0.074 mm, and the average CPA was 0.890 ± 0.141 mm2. CPL and CPA tended to be longer and larger in the superior quadrant (p < 0.001) than in the other three quadrants. Average CPL was significantly correlated with AL (r = 0.535, p < 0.001), ACD (r = 0.511, p < 0.001), and LT (r = −0.512, p < 0.001). Intraclass correlation coefficient (ICC) scores were high for CPL (0.979), CPD (0.992), CPA (0.966), CMA (0.963), and CBA (0.951). Conclusions: In healthy Chinese subjects, CPL was greatest in the superior quadrant, followed by the inferior, temporal, and nasal quadrants, and CPA was largest in the superior quadrant, followed by the tempdoral, inferior, and nasal quadrants. Transverse UBM images can be used to measure the anatomy of the ciliary process with relatively good repeatability and reliability.

27 July 2023 in American Journal of Ophthalmology
Verified
Journal Article
Open access
LFLei Fang
Lei Fang
YZYingting Zhu
Yingting Zhu
SLShufen Lin
Shufen Lin
YSYihua Su
Yihua Su
LCLiming Chen
Liming Chen
XLXing Liu
Xing Liu
To evaluate the outcomes of microcatheter-assisted trabeculotomy (MAT) in childhood glaucoma (primary congenital glaucoma [PCG], juvenile open-angle glaucoma [JOAG], and secondary childhood glaucoma [SCG]) after failed glaucoma surgery. Retrospective interventional case series. Patients with childhood glaucoma who underwent MAT after failed glaucoma surgery with at least 12 months of follow-up were evaluated. Pre- and postoperative intraocular pressure (IOP) and the number of glaucoma medications were recorded and compared. Success was defined as an IOP ≤21 mm Hg with or without glaucoma medication. Analysis of variance was used to compare the glaucoma subgroups. Forty-five eyes (42 patients) with a median follow-up period of 19 months were included. The median age at the time of MAT was 10 (range, 0.8-33) years. The mean number of previous surgeries was 1.3 ± 0.5. The IOP had significantly reduced from baseline in all PCG, JOAG, and SCG patients (27.9 ± 4.5 vs 16.3 ± 8.0 mm Hg, P = .001; and 30.8 ± 9.4 vs 13.5 ± 3.0 mm Hg, P < .001; and 31.5 ± 7.1 vs 16.5 ± 5.3 mm Hg, P = .001, respectively). Fewer glaucoma medications were needed after MAT in all 3 groups (each P < .001). At the last visit, the total success rates in PCG, JOAG, and SCG were 93.8%, 100%, and 88.9%, respectively. No severe complications were observed. MAT can effectively manage PCG, JOAG, and SCG after failed surgeries, providing successful outcomes and no serious complications. Following failed glaucoma surgeries, MAT may offer these patients with childhood glaucoma an excellent opportunity to achieve IOP control.

18 July 2023 in Ophthalmic Research
Verified
Journal Article
Open access
PDF file
SZShaoyang Zheng
Shaoyang Zheng
DWDingqiao Wang
Dingqiao Wang
ZHZhihong Huang
Zhihong Huang
ZWZhenyu Wang
Zhenyu Wang
YLYuan Liu
Yuan Liu
CZChengguo Zuo
Chengguo Zuo
Purpose: The aim of the study was to compare and explore the agreement between the nomogram tool and ultrasound biomicroscopy (UBM) images method to calculate the ultrasound cycloplasty (UCP) probe model in Chinese glaucoma patients. Methods: Retrospective analysis of Chinese glaucoma patients who visited Zhongshan Ophthalmic Center in Guangzhou from January to December 2019 and were eligible for UCP surgery. Visual acuity, intraocular pressure (IOP), ocular axial length (AL), and horizontal corneal diameter (white to white [WTW]) were measured. UBM images with clear ciliary body imaging and AL and WTW data were sent to trained personnel for probe model measurements. The data calculated by both methods were analyzed using unweighted and weighted κ statistics. The level of agreement refers to Landis and Koch’s guideline for the strength of agreement indicated with weighted κ values. Results: 1,061 eyes of 642 patients were involved, with a mean age of 61.66 ± 11.66 years. Their best-corrected visual acuity converted to logarithm of minimal-angle-of-resolution (logMAR) scores of −0.18–3.00 with a mean value of 0.69 ± 0.77. IOP was 22.0–60.0 mm Hg with a mean of 27.97 ± 5.66 mm Hg. The mean AL and WTW were 22.88 ± 1.33 (19.15–32.14) mm and 11.52 ± 0.49 (10.00–12.90) mm, respectively. The agreement between the two methods was fair (weighted κ = 0.299), matching in 62.86% of eyes (weighted κ = 0.299, κ = 0.264). The agreement in primary open angle glaucoma, acute primary angle-closure glaucoma, chronic primary angle-closure glaucoma, and secondary glaucoma patients was 60.85% (weighted κ = 0.336, κ = 0.301), 65.06% (weighted κ = 0.146, κ = 0.127), 62.26% (weighted κ = 0.204, κ = 0.184), and 57.97% (weighted κ = 0.332, κ = 0.280) of eyes, respectively. Conclusion: The agreement between UBM images and the nomogram tool to calculate the UCP probe model of Chinese patients is at a fair level. The nomogram tool prefers to use larger probes. Improvements to the nomogram tool, such as including data from more ethnic groups and being able to calculate separately for different types of glaucoma, are needed to improve accuracy. The inclusion of parameters or images from more directions of the eye may help measure probe models more accurately for both the nomogram tool and the UBM image measurement.