Hamed Moradi Tavasani

Mr. Hamed Moradi Tavasani

University of Manitoba, Winnipeg, Manitoba, Canada
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
SMSara Mantach
Sara Mantach
ALAbdulla Lutfi
Abdulla Lutfi
HTHamed Moradi Tavasani
Hamed Moradi Tavasani
AAAhmed Ashraf
Ahmed Ashraf
Ayman El-HagAyman El-Hag
Ayman El-Hag
Behzad KordiBehzad Kordi
Behzad Kordi
Condition monitoring of high voltage apparatus is of much importance for the maintenance of electric power systems. Whether it is detecting faults or partial discharges that take place in high voltage equipment, or detecting contamination and degradation of outdoor insulators, deep learning which is a branch of machine learning has been extensively investigated. Instead of using hand-crafted manual features as an input for the traditional machine learning algorithms, deep learning algorithms use raw data as the input where the feature extraction stage is integrated in the learning stage, resulting in a more automated process. This is the main advantage of using deep learning instead of traditional machine learning techniques. This paper presents a review of the recent literature on the application of deep learning techniques in monitoring high voltage apparatus such as GIS, transformers, cables, rotating machines, and outdoor insulators.

22 August 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
HTHamed Moradi Tavasani
Hamed Moradi Tavasani
WZWaldemar Ziomek
Waldemar Ziomek
Behzad KordiBehzad Kordi
Behzad Kordi
Partial discharges (PD) in transformer windings can lead to failures, causing power grid instability and outages. Therefore, early detection and accurate localization of PD incidents are crucial. This paper introduces an electrical approach for PD localization in transformer windings. The approach involves non-invasive injection of pulses (resembling PD) into the winding and recording the propagated signals at the winding terminals (i.e. line bushing and neutral ends). Noninvasive PD injection is performed using a capacitive coupling due to the absence of electrical access to transformer winding conductors. Next, features are extracted from the recorded signals to correlate them with the location of the injection point. This study investigates the effect of the PD pulse injection point on its response waveform recorded at the terminals to identify features corresponding to the PD source using a single measurement. Certain features of captured signals are highly correlated with PD location. The proposed approach establishes an accurate disk-to-disk localization model, particularly for large transformers. It employs a supervised classifier for PD localization. The performance of the proposed approach is verified using experimental measurements.

17 September 2025 in Electric Power Systems Research
Verified
Journal Article
Closed access
ANAmir Ali Kaabi Nejadian
Amir Ali Kaabi Nejadian
HTHamed Moradi Tavasani
Hamed Moradi Tavasani
MGManuja Gunawardana
Manuja Gunawardana
WZWaldemar Ziomek
Waldemar Ziomek
Behzad KordiBehzad Kordi
Behzad Kordi