The principle of duality is applied for electromagnetic transient (EMT) modeling of industry scale (i.e. 50, 390MVA) multilimb transformers. While saturation, hysteresis, deep-saturation, and remanent flux are accounted for, the need for transformer internal design information such as core dimension or material is eliminated. This is achieved by formulating the equivalent circuits with an alternative set of parameters that are either provided by the manufacturer or can be determined using conventional techniques. Open-circuit tests confirm that the models produce accurate excitation currents at different saturation levels when compared with measurement results. Furthermore, the models facilitate correct short-circuit condition with support for arbitrary number of windings. Upon validating the models, inrush current is simulated and the worst-case scenario is determined due to potential remanent flux values. The findings agree with an established EMT simulation model as well as manufacturer analytical approximations. Simulated hysteresis loops are also investigated.
30 November 2023 in IEEE Canadian Journal of Electrical and Computer Engineering
In this article, a new device to test the on-load tap changer (OLTC) is proposed. The presented device, which is called OLTC tap scan (OLTCTS), enables the user to find the location of the error without opening the transformer and removing OLTC. The proposed device applies the electrical parameters to the bushings of transformers and utilizes electrical parameters, such as voltage, current, current and voltage slopes, and resistance. All the mentioned electrical parameters are evaluated both statistically and dynamically in the presented device. Dynamic current ripple and dynamic voltage ripple are the main parameters that are evaluated for OLTC testing in this article. After designing and building this device, it was used for practical testing on three power transformers, and the results obtained from those tests are analyzed in this article.
22 August 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Partial discharges (PD) in transformer windings can lead to failures, causing power grid instability and outages. Therefore, early detection and accurate localization of PD incidents are crucial. This paper introduces an electrical approach for PD localization in transformer windings. The approach involves non-invasive injection of pulses (resembling PD) into the winding and recording the propagated signals at the winding terminals (i.e. line bushing and neutral ends). Noninvasive PD injection is performed using a capacitive coupling due to the absence of electrical access to transformer winding conductors. Next, features are extracted from the recorded signals to correlate them with the location of the injection point. This study investigates the effect of the PD pulse injection point on its response waveform recorded at the terminals to identify features corresponding to the PD source using a single measurement. Certain features of captured signals are highly correlated with PD location. The proposed approach establishes an accurate disk-to-disk localization model, particularly for large transformers. It employs a supervised classifier for PD localization. The performance of the proposed approach is verified using experimental measurements.
17 September 2025 in Electric Power Systems Research