Hongjian Gao

Dr. Hongjian Gao

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2012 in International Journal of Hyperthermia
Verified
Journal Article
Closed access
PDF file
HAHaiming Ai
Haiming Ai
SWShuicai Wu
Shuicai Wu
HGHongjian Gao
Hongjian Gao
LZLei Zhao
Lei Zhao
CYChunlan Yang
Chunlan Yang
YZYi Zeng
Yi Zeng
The temperature distribution in the region near a microwave antenna is a critical factor that affects the entire temperature field during microwave ablation of tissue. It is challenging to predict this distribution precisely, because the temperature in the near-antenna region varies greatly. The effects of water vaporisation and subsequent tissue carbonisation in an ex vivo porcine liver were therefore studied experimentally and in simulations. The enthalpy and high-temperature specific absorption rate (SAR) of liver tissues were calculated and incorporated into the simulation process. The accuracy of predictions for near-field temperatures in our simulations has reached the level where the average maximum error is less than 5°C. In addition, a modified thermal model that accounts for water vaporisation and the change in the SAR distribution pattern is proposed and validated with experiment. The results from this study may be useful in the clinical practice of microwave ablation and can be applied to predict the temperature field in surgical planning.

12 August 2024 in Tomography
Verified
Journal Article
Open access
YWYutong Wu
Yutong Wu
HGHongjian Gao
Hongjian Gao
CZChen Zhang
Chen Zhang
XMXiangge Ma
Xiangge Ma
XZXinyu Zhu
Xinyu Zhu
LLLan Lin
Lan Lin
The concept of ‘brain age’, derived from neuroimaging data, serves as a crucial biomarker reflecting cognitive vitality and neurodegenerative trajectories. In the past decade, machine learning (ML) and deep learning (DL) integration has transformed the field, providing advanced models for brain age estimation. However, achieving precise brain age prediction across all ages remains a significant analytical challenge. This comprehensive review scrutinizes advancements in ML- and DL-based brain age prediction, analyzing 52 peer-reviewed studies from 2020 to 2024. It assesses various model architectures, highlighting their effectiveness and nuances in lifespan brain age studies. By comparing ML and DL, strengths in forecasting and methodological limitations are revealed. Finally, key findings from the reviewed articles are summarized and a number of major issues related to ML/DL-based lifespan brain age prediction are discussed. Through this study, we aim at the synthesis of the current state of brain age prediction, emphasizing both advancements and persistent challenges, guiding future research, technological advancements, and improving early intervention strategies for neurodegenerative diseases.

1 January 2019 in International Journal of Hyperthermia
Verified
Journal Article
Open access
HGHongjian Gao
Hongjian Gao
XWXiaoru Wang
Xiaoru Wang
SWShuicai Wu
Shuicai Wu
Zhuhuang ZhouZhuhuang Zhou
Zhuhuang Zhou
YBYanping Bai
Yanping Bai
WWWeiwei Wu
Weiwei Wu
Purpose: To optimize treatment schemes using 2450-MHz microwave ablation (MWA), a novel conformal coverage method based on bipolar-angle mapping is proposed that determines whether a liver tumor is completely encompassed by thermal coagulation zones. Materials and methods: Firstly, three-dimensional (3-D) triangular mesh data of liver tumors were reconstructed from clinical computed tomography (CT) slices using the Marching cubes (MC) algorithm. Secondly, characterization models of thermal coagulation zones were established based on finite element simulation results of 40, 45, 50, 55, and 60 W ablations. Finally, coagulation zone models and tumor surface data were mapped and fused on a two-dimensional (2-D) plane to achieve conformal coverage of liver tumors by comparing the corresponding polar radii. Results: Optimal parameters for ablation treatment of liver tumors were efficiently obtained with the proposed conformal coverage method. Fifteen liver tumors were obtained with maximal diameters of 12.329–78.612 mm (mean ± standard deviation, 39.094 ± 19.447 mm). The insertion positions and orientations of the MWA antenna were determined based on 3-D reconstruction results of these tumors. The ablation patterns and durations of tumors were planned according to the minimum mean standard deviations between the ablative margin and tumor surface. Conclusion: The proposed method can be applied to computer-assisted MWA treatment planning of liver tumors, and is expected to guide clinical procedures in future.

30 September 2021 in Frontiers in Bioscience-Landmark
Verified
Journal Article
Open access
JWJinying Wang
Jinying Wang
SWShuicai Wu
Shuicai Wu
ZWZeyi Wu
Zeyi Wu
HGHongjian Gao
Hongjian Gao
SHShengyang Huang
Shengyang Huang
Highlights: (1) A 3D simulation model of MWA (microwave ablation) based on the temperature-dependent characteristic parameters and blood flow parameters was established to realize the visual simulation of temperature distribution and coagulation zone. The internal forced convection condition was used to accurately characterize the large vessel. (2) The ex vivo MWA experimental platform was built to verify the accuracy of the simulation model. A peristaltic pump was employed for operatively controlling blood circulation and a medical soft plastic tube was introduced for appropriately simulating a blood vessel. (3) The influences of blood flow parameters of large vessels on temperature distribution and coagulation zone were systematically analyzed in order to provide reference and guidance for MWA clinicians. Purpose: Clinical MWA of liver tumor is significantly limited by the accurate prediction of vascular cooling effects. To provide reference and guidance for clinical MWA of liver tumor, the three-dimensional effects of different blood flow parameters of large vessels on MWA temperature distribution were systematically evaluated. Materials and methods: Firstly, the MWA three-dimensional finite element simulation model with blood flow parameters was established. Secondly, to verify the effectiveness of the model, MWA was performed ex vivo in porcine liver for 360 s and the temperature was measured by thermocouples. A medical soft plastic tube was placed parallel to the MWA antenna to simulate a natural liver vessel. Finally, based on this model, the influences of different vessel diameters and vessel-antenna spacings on MWA temperature distribution were analyzed. Results: Sixteen ablations were performed to verify the accuracy of the simulation model. The mean temperature errors between measured data and simulation results at six measurement points were 3.87 ℃. In the first 10 seconds of MWA, the vessel cooling effect on temperature distribution was negligible. When the vessel-antenna spacing was 5 mm and the vessel diameter varied from 3 mm to 6 mm, the temperature at the measured point near the vessel decreased by 2.11 ℃ at 360 s. When the vessel diameter was 6 mm and the vessel-antenna spacing varied from 5 mm to 7 mm, the temperature at the measured point near the vessel reduced by 14.91 ℃ at 360 s. In addition, blood diameter had little influence on the temperature distribution near the heating point. The volume of coagulation zone will not be obviously affected once the vessel lies outside the predicted coagulation zone. Conclusions: The MWA simulation model with blood flow parameters is established. Vessel-antenna spacing is the primary factor affecting the temperature distribution. A vessel with larger diameter can have a more significant effect on the temperature distribution. The large vessel will take away and block part of conduction heat, so the coagulation zone will not be formed on the lateral side of the vessel.

1 January 2018 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
XWXiaoru Wang
Xiaoru Wang
HGHongjian Gao
Hongjian Gao
SWShuicai Wu
Shuicai Wu
YBYanping Bai
Yanping Bai
Zhuhuang ZhouZhuhuang Zhou
Zhuhuang Zhou
OBJECTIVE: The aim of the research is to obtain the relative influences of some critical electro-thermal parameters on the ablation temperature and lesion volume during temperature-controlled radiofrequency ablation (RFA) of liver tumor by parameter

20 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JWJinying Wang
Jinying Wang
SHShengyang Huang
Shengyang Huang
HGHongjian Gao
Hongjian Gao
JLJu Liu
Ju Liu
YZYubo Zhang
Yubo Zhang
SWShuicai Wu
Shuicai Wu
Single-antenna microwave ablation (MWA) is mainly used to treat small tumors less than 3 cm in diameter. To obtain a larger coagulation zone in a single ablation, a dual-antenna ablation approach was proposed. A three-dimensional finite element method (FEM) simulation model of parallel dual-antennas was developed. Ex vivo experiments at 50 W for 8 min were performed to verify the model. Both the temperature changes in tissue and the size of the coagulation zone were recorded. The effects of dual-antenna spacing, heating power, and blood perfusion on the coagulation zone were analyzed. Fifteen experiments were carried out. The errors between the mean measurements and simulated results at the set temperature points were 1.08 °C, 0.95 °C, and 2.1 °C, respectively. For the same conditions, the blood perfusion of 1.0, 1.5, and 3.0 kg/(m3·s) can result in a reduction in the coagulation volume by 18.4%, 25.4%, and 42.5%. As the spacing increased, the coagulation zone of each antenna started to fuse together later and the resulting integral coagulation zone became larger. Dual-antenna MWA is expected to be used for the treatment of tumors larger than 5 cm in diameter.