Mihailo Ristic

Dr. Mihailo Ristic

orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2000 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
IAI. Ainsworth
I. Ainsworth
Mihailo RisticMihailo Ristic
Mihailo Ristic
DBD. Brujic
D. Brujic

3 September 2015 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
EFEnrico Franco
Enrico Franco
DBDjordje Brujic
Djordje Brujic
MRMarc Rea
Marc Rea
WGWladyslaw M. Gedroyc
Wladyslaw M. Gedroyc
Mihailo RisticMihailo Ristic
Mihailo Ristic
This paper presents the design, control, and experimental evaluation of a needle-guiding robot intended for use in laser ablation (LA) of liver tumors under guidance by magnetic resonance imaging (MRI). The robot provides alignment of a needle guide inside the MRI scanner bore and employs manual needle insertion. In order to minimize MR-image deterioration, the robot is actuated using plastic pneumatic cylinders and long pipes connecting to control valves located outside the MRI scanner room. A new time-delay control scheme was employed to achieve high position accuracy without requiring pressure or force measurements in the MRI scanner. The control scheme was compared with experiments to a previously developed sliding mode controller. A marker localization method based on the convolution theorem of Fourier transform was employed to register the robot in the MRI scanner coordinate system and to verify the position of the needle guide before the manual needle insertion. Experiments in a closed-bore MRI scanner showed a variation in SNR below 5%. A phantom study indicates that the targeting error in robot-assisted needle insertions is below 5 mm and suggest a potential time saving of 30 min compared to the manual MRI-guided LA procedure.

30 September 2010 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
DBDjordje Brujic
Djordje Brujic
IAIain Ainsworth
Iain Ainsworth
Mihailo RisticMihailo Ristic
Mihailo Ristic

3 March 2009 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
ZTZion Tse
Zion Tse
HJH Janssen
H Janssen
AHA Hamed
A Hamed
Mihailo RisticMihailo Ristic
Mihailo Ristic
IYI Young
I Young
MLM Lamperth
M Lamperth
Magnetic resonance elastography (MRE) is an emerging technique capable of measuring the shear modulus of tissue. A suspected tumour can be identified by comparing its properties with those of tissues surrounding it; this can be achieved even in deep-lying areas as long as mechanical excitation is possible. This would allow non-invasive methods for cancer-related diagnosis in areas not accessible with conventional palpation. An actuating mechanism is required to generate the necessary tissue displacements directly on the patient in the scanner and three different approaches, in terms of actuator action and position, exist to derive stiffness measurements. However, the magnetic resonance (MR) environment places considerable constraints on the design of such devices, such as the possibility of mutual interference between electrical components, the scanner field, and radio frequency pulses, and the physical space restrictions of the scanner bore. This paper presents a review of the current solutions that have been developed for MRE devices giving particular consideration to the design criteria including the required vibration frequency and amplitude in different applications, the issue of MR compatibility, actuation principles, design complexity, and scanner synchronization issues. The future challenges in this field are also described.

15 November 2000 in Journal of Materials Processing Technology
Verified
Journal Article
Closed access
TRT.M Rupp
T.M Rupp
Mihailo RisticMihailo Ristic
Mihailo Ristic

1 January 2003 in International Journal of Production Research
Verified
Journal Article
Closed access
HXH. Q. Xu
H. Q. Xu
CBC. B. Besant
C. B. Besant
Mihailo RisticMihailo Ristic
Mihailo Ristic