Wan-Tai Au-Yeung

Dr. Wan-Tai Au-Yeung


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2020 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
RSRahul Kumar Sevakula
Rahul Kumar Sevakula
WAWan-Tai Au-Yeung
Wan-Tai Au-Yeung
JSJagmeet P. Singh
Jagmeet P. Singh
EHE. Kevin Heist
E. Kevin Heist
EIEric M. Isselbacher
Eric M. Isselbacher
AAAntonis Armoundas
Antonis Armoundas

26 November 2020 in Digital Biomarkers
Verified
Journal Article
Open access
PDF file
ZBZachary Beattie
Zachary Beattie
LMLyndsey M. Miller
Lyndsey M. Miller
CACarlos Almirola
Carlos Almirola
WAWan-Tai Au-Yeung
Wan-Tai Au-Yeung
HBHannah Bernard
Hannah Bernard
JKJeffrey Kaye
Jeffrey Kaye
Introduction: Future digital health research hinges on methodologies to conduct remote clinical assessments and in-home monitoring. The Collaborative Aging Research Using Technology (CART) initiative was introduced to establish a digital technology research platform that could widely assess activity in the homes of diverse cohorts of older adults and detect meaningful change longitudinally. This paper reports on the built end-to-end design of the CART platform, its functionality, and the resulting research capabilities. Methods: CART platform development followed a principled design process aiming for scalability, use case flexibility, longevity, and data privacy protection while allowing sharability. The platform, comprising ambient technology, wearables, and other sensors, was deployed in participants’ homes to provide continuous, long-term (months to years), and ecologically valid data. Data gathered from CART homes were sent securely to a research server for analysis and future data sharing. Results: The CART system was created, iteratively tested, and deployed to 232 homes representing four diverse cohorts (African American, Latinx, low-income, and predominantly rural-residing veterans) of older adults (n = 301) across the USA. Multiple measurements of wellness such as cognition (e.g., mean daily computer use time = 160–169 min), physical mobility (e.g., mean daily transitions between rooms = 96–155), sleep (e.g., mean nightly sleep duration = 6.3–7.4 h), and level of social engagement (e.g., reports of overnight visitors = 15–45%) were collected across cohorts. Conclusion: The CART initiative resulted in a minimally obtrusive digital health-enabled system that met the design principles while allowing for data capture over extended periods and can be widely used by the research community. The ability to monitor and manage health digitally within the homes of older adults is an important alternative to in-person assessments in many research contexts. Further advances will come with wider, shared use of the CART system in additional settings, within different disease contexts, and by diverse research teams.

5 September 2019 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
WAWan-Tai Au-Yeung
Wan-Tai Au-Yeung
ASAshish K. Sahani
Ashish K. Sahani
EIEric M. Isselbacher
Eric M. Isselbacher
AAAntonis Armoundas
Antonis Armoundas
This work attempts to reduce the number of false alarms generated by bedside monitors in the intensive care unit (ICU), as a majority of current alarms are false. In this study, we applied methods that can be categorized into three stages: signal processing, feature extraction, and optimized machine learning. At the stage of signal processing, we ensured that the heartbeats were properly annotated. During feature extraction, besides extracting features that are relevant to the arrhythmic alarms, we also extracted a set of signal quality indices (SQIs), which we used to distinguish noise/artifact from normal physiological signals. When applying a machine learning algorithm (Random Forest), we performed feature selection in order to reduce the complexity of the models and improve the efficiency of the algorithm. The dataset used is from Reducing False Arrhythmia Alarms in the ICU: the PhysioNet/Computing in Cardiology Challenge 2015. Using the performance metric “score” from the Challenge, we achieved a score of 83.08 in the real-time category on the hidden test set, which is the highest in all published work.

14 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WAWan-Tai Au-Yeung
Wan-Tai Au-Yeung
PRPer G Reinhall
Per G Reinhall
GBGust H Bardy
Gust H Bardy
SBSteven L Brunton
Steven L Brunton
Implantable-cardioverter defibrillators (ICD) detect and terminate life-threatening ventricular tachyarrhythmia with electric shocks after they occur. This puts patients at risk if they are driving or in a situation where they can fall. ICD’s shocks are also very painful and affect a patient’s quality of life. It would be ideal if ICDs can accurately predict the occurrence of ventricular tachyarrhythmia and then issue a warning or provide preventive therapy. Our study explores the use of ICD data to automatically predict ventricular arrhythmia using heart rate variability (HRV). A 5 minute and a 10 second warning system are both developed and compared. The participants for this study consist of 788 patients who were enrolled in the ICD arm of the Sudden Cardiac Death–Heart Failure Trial (SCD-HeFT). Two groups of patient rhythms, regular heart rhythms and pre-ventricular-tachyarrhythmic rhythms, are analyzed and different HRV features are extracted. Machine learning algorithms, including random forests (RF) and support vector machines (SVM), are trained on these features to classify the two groups of rhythms in a subset of the data comprising the training set. These algorithms are then used to classify rhythms in a separate test set. This performance is quantified by the area under the curve (AUC) of the ROC curve. Both RF and SVM methods achieve a mean AUC of 0.81 for 5-minute prediction and mean AUC of 0.87–0.88 for 10-second prediction; an AUC over 0.8 typically warrants further clinical investigation. Our work shows that moderate classification accuracy can be achieved to predict ventricular tachyarrhythmia with machine learning algorithms using HRV features from ICD data. These results provide a realistic view of the practical challenges facing implementation of machine learning algorithms to predict ventricular tachyarrhythmia using HRV data, motivating continued research on improved algorithms and additional features with higher predictive power.

1 January 2022 in The American Journal of Geriatric Psychiatry
Verified
Journal Article
Closed access
WAWan-Tai Au-Yeung
Wan-Tai Au-Yeung
LMLyndsey Miller
Lyndsey Miller
ZBZachary Beattie
Zachary Beattie
RMRose May
Rose May
HCHailey V. Cray
Hailey V. Cray
IVIpsit V. Vahia
Ipsit V. Vahia

1 January 2020 in Alzheimer's & Dementia: Translational Research & Clinical Interventions
Verified
Journal Article
Open access
PDF file
WAWan-Tai Au-Yeung
Wan-Tai Au-Yeung
LMLyndsey Miller
Lyndsey Miller
ZBZachary Beattie
Zachary Beattie
HDHiroko H. Dodge
Hiroko H. Dodge
CRChristina Reynolds
Christina Reynolds
JKJeffrey Kaye
Jeffrey Kaye
Introduction: Agitation, experienced by patients with dementia, is difficult to manage and stressful for caregivers. Currently, agitation is primarily assessed by caregivers or clinicians based on self‐report or very brief periods of observation. This limits availability of comprehensive or sensitive enough reporting to detect early signs of agitation or identify its precipitants. The purpose of this article is to provide proof of concept for characterizing and predicting agitation using a system that continuously monitors patients’ activities and living environment within memory care facilities. Methods: Continuous and unobtrusive monitoring of a participant is achieved using behavioral sensors, which include passive infrared motion sensors, door contact sensors, a wearable actigraphy device, and a bed pressure mat sensor installed in the living quarters of the participant. Environmental sensors are also used to continuously assess temperature, light, sound, and humidity. Episodes of agitation are reported by nursing staff. Data collected for 138 days were divided by 8‐hour nursing shifts. Features from agitated shifts were compared to those from non‐agitated shifts using t ‐tests. Results: A total of 37 episodes of agitation were reported for a male participant, aged 64 with Alzheimer's disease, living in a memory care unit. Participant activity metrics (eg, transitions within the living room, sleep scores from the bedmat, and total activity counts from the actigraph) significantly correlated with occurrences of agitation at night ( P < 0.05). Environmental variables (eg, humidity) also correlated with the occurrences of agitation at night ( P < 0.05). Higher activity levels were also observed in the evenings before agitated nights. Discussion: A platform of sensors used for unobtrusive and continuous monitoring of participants with dementia and their living space seems feasible and shows promise for characterization of episodes of agitation and identification of behavioral and environmental precipitants of agitation.