Background: Large cavity designs and access cavities impair endodontically treated tooth fracture resistance. As the tooth’s strength is known to reduce significantly after the root canal treatment, occlusal loading as a result of functions such as chewing, biting and certain parafunctional tendencies makes the endodontically treated tooth vulnerable to fracture. Hence, after endodontic treatment, it is vital to give adequate and appropriate restorative material to avoid tooth fractures. Accordingly, the choice of such restorative material should be dictated by the property of fracture resistance. Objective: The goal of this study was to conduct a systematic review and critical analysis of available data from in vitro studies examining the fracture resistance of endodontically treated posterior teeth restored with fiber-reinforced composites. Methodology: The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRIS-MA) Statement was used to guide the reporting of this systematic review A comprehensive literature search was performed using MEDLINE (via PubMed), Scopus, ScienceDirect, Google Scholar, and LILACS. A manual search of the reference lists of the articles was also performed. The databases provided a total of 796 studies from the electronic systematic search. The databases provided a total of 796 studies from the electronic systematic search. Two reviewers scrutinized the papers for eligibility based on inclusion/exclusion criteria and extracted data. The studies were assessed for their potential risk of bias. Based on modified JBI & CRIS (checklist for reporting in vitro studies) guidelines, along with the methodology and treatment objective, we have formulated 13 parameters specifically to assess the risk of bias. A total of 18 studies met the inclusion criteria and were included for qualitative analysis. Considering the high heterogeneity of the studies included, a meta-analysis could not be performed. Results: The majority of the included studies had a moderate or high risk of bias. When compared to traditional hybrid composites, fiber-reinforced composites showed increased fracture resistance of endodontically treated teeth in the majority of investigations. On the other hand, limited evidence was found for the bulk fill composites. Moreover, moderate evidence was found for the fracture resistance of inlays and fiber posts with fiber-reinforced composites for core build-up in endodontically treated teeth. No evidence could be found comparing the fracture resistance of endo crowns and fiber-reinforced composites in endodontically treated teeth. Conclusion: According to the research, using fiber-reinforced composites instead of conventional hybrid composites improves the fracture resistance of endodontically treated teeth. However, there was a high risk of bias in the research considered. No judgments could be reached about the superiority of one material over another based-on comparisons between other core restorations.
The healing of the periapical tissues is crucial to the success of root canal treatment. The review studies effectively examine various endodontic root canal sealants in terms of periapical healing. This systematic review was formulated following the PRISMA 2020 guidelines and registered in the international prospective register of systematic reviews (PROSPERO) number‐CRD42021239192. To find relevant articles, PubMed Central and Medline databases (until February 2022) were searched. Studies that evaluated healing following the application of different endodontic sealers were analysed. A primary outcome measure was the resolution of periapical lesions following the endodontic treatment. In vivo studies comparing radiographic treatment outcomes and articles with a minimum of 6‐month follow‐up were included. A total of 9 clinical trial studies that met all the inclusion criteria were included in the analysis. The overall risk of bias was high in four studies out of nine studies. Periapical lesions showed significant healing after endodontic treatment regardless of sealer type, although bioceramic and bioactive sealers had shown better results.
Background: the efficiency of the diagnostic aids plays an important role in the treatment plan. This study aims to assess the diagnostic accuracy of dental pulse oximeter with a customized sensor holder, thermal test and electric pulp tester in assessing the actual pulp status and to evaluate the oxygen saturation level in control healthy teeth, non-vital and teeth with irreversible pulpitis. Material and methods: thirty-seven single canal teeth requiring endodontic therapy were included in the study. The selected teeth were tested with dental pulse oximeter, electric pulp test, cold spray, and heated gutta percha stick. Between each test a time lag of 2 minutes was allowed for the central sensitization to occur. Three blinded operators were involved in the study. The actual status of the pulp was evaluated after the initiation of endodontic treatment. To assess the actual pulp status direct visual examination of access cavity as performed. The data was statistically analysed using (ANOVA) Analysis of Variance and Post-hoc Tukey test. Results: sensitivity of pulse oximeter, heat test, cold and electric pulp test, was 100, 25, 50, and 12, respectively. The specificity of these tests was 100, 72 81, and 77, respectively. The ANOVA showed that there was statistical difference between all the groups (p=0.0005). Post-Hoc Tukey revealed that there was statistical difference among all the groups, nonvital group (p=0.0005), control group (p=0.01) and for irreversible pulpitis (p=0.01). The overall diagnostic accuracy of pulse oximeter was 100% followed by cold test 66%, heat test to be 49% and electric pulp test to be 45%. Conclusion: the custom-made holder used in the present study aided in providing accurate response for pulp vitality testing. In this study the diagnostic accuracy was high with dental pulse oximeter followed by cold, heat and the least was electric pulp tester in different pulpal conditions.KEYWORDS Cold test; Heat test; Oxygen saturation; Pulse oximeter; Vitality tests.
The interest in the use of green-mediated synthesis of nanoparticles (NPs) is shown to have increased due to their biocompatibility and reduction of overall production costs. The current study aimed to evaluate a novel nanocomposite (NC) prepared by using a combination of zinc oxide, silver and chitosan with lemon extract as a cross-linking agent and assessed its antimicrobial effectiveness against Enterococcus faecalis (E. faecalis). The NPs and NC were prepared individually using a modification of previously established methods. Ananalys is of the physiochemical properties of the NC was conducted using ultraviolet-visible spectroscopy (UV-Vis) (Shimadzu Corporation, Kyoto, Japan). and transmission electron microscopy (TEM) imaging(HR-TEM; JEOL Ltd., Akishima-shi, Japan. The microbial reduction with this novel NC was evaluated by measuring the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) using a tube assay analytic technique. A time-kill assay analysis was conducted to evaluate the kinetic potential against E. faecalis at different time intervals. The novel NC showed a homogenous nanoparticle size under TEM imaging and under UV-Vis established an absorption range of 350–420 nm making it similar to its individual counterparts. The MIC and MIB were measured at 62.5 ± 20 mg/L (p < 0.05) and 250 ± 72 mg/L (p < 0.05), respectively. A time-kill assay analysis for the NC showed 5 h was required to eradicate E. faecalis. Based on the achieved results, it was seen that the novel NC using a combination of silver, zinc oxide and chitosan showed improved antimicrobial action against E. faecalis compared with its individual components under laboratory conditions. A complete eradication of 108 log units of E. faecalis at 250 mg/L occurred after a total of 5 h. These preliminary results establish the use of lemon extract-mediated silver, zinc and chitosan-based NC had an antibacterial effectiveness against E. faecalis similar to the individual counterparts used for its production under laboratory conditions.
1 February 2019 in Journal of Maxillofacial and Oral Surgery
Esthetics, improved colour stability and ease of contour have made photo-activated resin based restorative materials being widely used in routine dental clinical practice. Perhaps improper and inadequate polymerization of resin based composite material might lead to elution of monomer. Thus, the aim of the current study was to quantify the monomer elution from three resin composites. The intended analysis was made using high performance liquid chromatography (HPLC) at two different time periods. Three different materials that were investigated in the current study included Swiss Tech resin composite (Group A), Ceram X (Group B) and Beautifil Injectable composite (Group C). Ten cylindrical samples were fabricated in each study group. In 75% wt of ethanol, the samples were ingressed immediately and stored at room temperature. A 0.5 mL of the samples was assessed at pre-defined time intervals at 24 h and 7th day. Later, assessment of the samples was performed with HPLC and the data was analyzed using statistical test. Bisphenol A-glycidyl methacrylate (Bis-GMA), Triethylene glycol dimethacrylate (TEGDMA), 2-hydroxyethyl methacrylate (HEMA) and Urethane dimethacrylate (UDMA) were quantified in the samples. When analyzing the release monomer, it was found that at the end of 24 h Bis-GMA was eluted more in the injectable resin composite whereas, TEGDMA was eluted from Swiss Tech and Ceram X resin composites. At the end of the 7th day it was evident that Bis-GMA was eluted maximum in all the three resin composites. Thus, monomer release was found to be evident among all three resin composites and it is of utmost important to be assessed in routine clinical practice.