BACKGROUND AND PURPOSE: Many patients with dementia may have comorbid or misdiagnosed normal pressure hydrocephalus, a treatable neurologic disorder. The callosal angle is a validated biomarker for normal pressure hydrocephalus with 93% diagnostic accuracy. Our purpose was to develop and evaluate an algorithm for automatically computing callosal angles from MR images of the brain. MATERIALS AND METHODS: This article reports the results of analyzing callosal angles from 1856 subjects with 5264 MR images from the Open Access Series of Imaging Studies and the Alzheimer’s Disease Neuroimaging Initiative databases. Measurement variability was examined between 2 neuroradiologists (n = 50) and between manual and automatic measurements (n = 281); from differences in simulated head orientation; and from real-world changes in patients with multiple examinations (n = 906). We evaluated the effectiveness of the automatic callosal angle to differentiate normal pressure hydrocephalus from Alzheimer disease in a simulated cohort. RESULTS: The algorithm identified that 12.4% of subjects from these carefully screened cohorts had callosal angles of <90°, a published threshold for possible normal pressure hydrocephalus. The intraclass correlation coefficient was 0.97 for agreement between neuroradiologists and 0.90 for agreement between manual and automatic measurement. The method was robust to different head orientations. The median coefficient of variation for repeat examinations was 4.2% (Q1 = 3.1%, Q3 = 5.8%). The simulated classification of normal pressure hydrocephalus versus Alzheimer using the automatic callosal angle had an accuracy, sensitivity, and specificity of 0.87 each. CONCLUSIONS: In even the most pristine research databases, analyses of the callosal angle indicate that some patients may have normal pressure hydrocephalus. The automatic callosal angle measurement can rapidly and objectively screen for normal pressure hydrocephalus in patients who would otherwise be misdiagnosed.
In vivo MR spectroscopy is a non -invasive methodology that provides information about the biochemistry of tissues. It is available as a “push-button” application on state-of-the-art clinical MR scanners. MR spectroscopy has been used to study various brain diseases including tumors, stroke, trauma, degenerative disorders, epilepsy/seizures, inborn errors, neuropsychiatric disorders, and others. The purpose of this review is to provide an overview of MR spectroscopy findings in the pediatric population and its clinical use.
<!-- *** Custom HTML *** --> Purpose: To evaluate six cerebral arterial segmentation algorithms in a set of patients with a wide range of hemodynamic characteristics to determine real-world performance. Approach: Time-of-flight magnetic resonance angiograms were acquired from 33 subjects: normal controls (N = 11), sickle cell disease (N = 11), and non-sickle anemia (N = 11) using a 3 Tesla Philips Achieva scanner. Six segmentation algorithms were tested: (1) Otsu’s method, (2) K-means, (3) region growing, (4) active contours, (5) minimum cost path, and (6) U-net machine learning. Segmentation algorithms were tested with two region-selection methods: global, which selects the entire volume; and local, which iteratively tracks the arteries. Five slices were manually segmented from each patient by two readers. Agreement between manual and automatic segmentation was measured using Matthew’s correlation coefficient (MCC). Results: Median algorithm segmentation times ranged from 0.1 to 172.9 s for a single angiogram versus 10 h for manual segmentation. Algorithms had inferior performance to inter-observer vessel-based (p < 0.0001, MCC = 0.65) and voxel-based (p < 0.0001, MCC = 0.73) measurements. There were significant differences between algorithms (p < 0.0001) and between patients (p < 0.0042). Post-hoc analyses indicated (1) local minimum cost path performed best with vessel-based (p = 0.0261, MCC = 0.50) and voxel-based (p = 0.0131, MCC = 0.66) analyses; and (2) higher vessel-based performance in non-sickle anemia (p = 0.0002) and lower voxel-based performance in sickle cell (p = 0.0422) compared with normal controls. All reported MCCs are medians. Conclusions: The best-performing algorithm (local minimum cost path, voxel-based) had 9.59% worse performance than inter-observer agreement but was 3 orders of magnitude faster. Automatic segmentation was non-inferior in patients with sickle cell disease and superior in non-sickle anemia.