Yoshitaka Sakata

Dr. Yoshitaka Sakata

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Energy Conversion and Management
Verified
Journal Article
Closed access
ASAhmed A. Serageldin
Ahmed A. Serageldin
ARAli Radwan
Ali Radwan
TKTakao Katsura
Takao Katsura
YSYoshitaka Sakata
Yoshitaka Sakata
SNShigeyuki Nagasaka
Shigeyuki Nagasaka
KNKatsunori Nagano
Katsunori Nagano

18 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
Ahmed SerageldinAhmed Serageldin
Ahmed Serageldin
Ali RadwanAli Radwan
Ali Radwan
YSYoshitaka Sakata
Yoshitaka Sakata
Takao KatsuraTakao Katsura
Takao Katsura
Katsunori NaganoKatsunori Nagano
Katsunori Nagano
New small-scale experiments are carried out to study the effect of groundwater flow on the thermal performance of water ground heat exchangers for ground source heat pump systems. Four heat exchanger configurations are investigated; single U-tube with circular cross-section (SUC), single U-tube with an oval cross-section (SUO), single U-tube with circular cross-section and single spacer with circular cross-section (SUC + SSC) and single U-tube with an oval cross-section and single spacer with circular cross-section (SUO + SSC). The soil temperature distributions along the horizontal and vertical axis are measured and recorded simultaneously with measuring the electrical energy injected into the fluid, and the borehole wall temperature is measured as well; consequently, the borehole thermal resistance (Rb) is calculated. Moreover, two dimensional and steady-state CFD simulations are validated against the experimental measurements at the groundwater velocity of 1000 m/year with an average error of 3%. Under saturated conditions without groundwater flow effect; using a spacer with SUC decreases the Rb by 13% from 0.15 m·K/W to 0.13 m·K/W, also using a spacer with the SUO decreases the Rb by 9% from 0.11 m·K/W to 0.1 m·K/W. In addition, the oval cross-section with spacer SUO + SSC decreases the Rb by 33% compared with SUC. Under the effect of groundwater flow of 1000 m/year; Rb of the SUC, SUO, SUC + SSC and SUO + SSC cases decrease by 15.5%, 12.3%, 6.1% and 4%, respectively, compared with the saturated condition.

29 March 2017 in Hydrology
Verified
Journal Article
Open access
PDF file
YSYoshitaka Sakata
Yoshitaka Sakata
Takao KatsuraTakao Katsura
Takao Katsura
Katsunori NaganoKatsunori Nagano
Katsunori Nagano
MIManabu Ishizuka
Manabu Ishizuka
Heat advection caused by groundwater flow can potentially improve the performance of a borehole heat exchanger. However, the required flow velocity is not achieved under most natural conditions. This study focuses on artificial groundwater flow generated by pumping and investigates the associated effect in a lowland area near the Toyohira River alluvial fan, Sapporo, Japan. Thermal response test results are compared under natural and artificial groundwater flow conditions. A pumping well is constructed one meter from the borehole. Temperature profiles are measured in the U-tube during testing, using a pair of optic fiber distributed temperature sensors. The effective thermal conductivity is calculated from the profiles obtained in each 10-m sub-layer; this thermal conductivity is termed the stepwise thermal conductivity. Additionally, the upward flow velocity in the pumping well is measured to estimate the mean groundwater flow velocity at the borehole. The results show that effective thermal conductivity increases at depths less than 50 m, where the pumping creates mean velocities greater than 0.1 m d−1 in each sub-layer (1.5 md−1 on average). Thus, a borehole length of 50 m is more reasonable at the test site for its efficiency in a ground source heat pump system coupled with the pumping well than that used.

31 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
Takao KatsuraTakao Katsura
Takao Katsura
YSYoshitaka Sakata
Yoshitaka Sakata
LDLan Ding
Lan Ding
Katsunori NaganoKatsunori Nagano
Katsunori Nagano
The authors developed a ground heat exchanger (GHE) calculation model influenced by the ground surface by applying the superposition theorem. Furthermore, a simulation tool for ground source heat pump (GSHP) systems affected by ground surface was developed by combining the GHE calculation model with the simulation tool for GSHP systems that the authors previously developed. In this paper, the outlines of GHE calculation model is explained. Next, in order to validate the calculation precision of the tool, a thermal response test (TRT) was carried out using a borehole GHE with a length of 30 m and the outlet temperature of the GHE calculated using the tool was compared to the measured one. The relative error between the temperatures of the heat carrier fluid in the GHE obtained by measurement and calculation was 3.3% and this result indicated that the tool can reproduce the measurement with acceptable precision. In addition, the authors assumed that the GSHP system was installed in residential houses and predicted the performances of GSHP systems using the GHEs with different lengths and numbers, but the same total length. The result showed that the average surface temperature of GHE with a length of 10 m becomes approximately 2 °C higher than the average surface temperature of a GHE with a length of 100 m in August.

6 January 2019 in Hydrology
Verified
Journal Article
Open access
PDF file
Kazuhisa Augustine ChikitaKazuhisa Augustine Chikita
Kazuhisa Augustine Chikita
YOYasuhiro Ochiai
Yasuhiro Ochiai
HOHideo Oyagi
Hideo Oyagi
YSYoshitaka Sakata
Yoshitaka Sakata
Kuttara Volcano, Hokkaido, Japan, consists of temperate Lake Kuttara and the western Noboribetsu geothermal area. In order to explore geothermal relations between Lake Kuttara and the geothermal area, the heat budget of a hydrothermal pond, Okunoyu, was evaluated, and the heat storage change in the lower layer of Lake Kuttara was calculated by monitoring the water temperature at the deepest point. The lake water temperature consistently increased during the thermal stratification in June–November of 2013–2016. The heat flux QB at lake bottom was then calculated at a range of 4.1–10.9 W/m2, which is probably due to the leakage from a hydrothermal reservoir below the lake bottom. Meanwhile, the heat flux HGin by geothermal groundwater input in Okunoyu was evaluated at 3.5–8.5 kW/m2, which is rapidly supplied through faults from underlying hydrothermal reservoirs. With a time lag of 5 months to monthly mean QB values in Lake Kuttara, the correlation with monthly mean HGin in Okunoyu was significant (R2 = 0.586; p < 0.01). Applying Darcy’s law to the leakage from the hydrothermal reservoir at 260–310 m below the lake bottom, the time needed for groundwater’s passage through the media 260–310 m thick was evaluated at 148–149 days (ca. 5 months). These findings suggest that the hydrothermal reservoir below lake bottom and the underlying hydrothermal reservoirs in the western geothermal area are both connected to a unique geothermal source in the deeper zone as a geothermal flow system of Kuttara Volcano.

28 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
YSYoshitaka Sakata
Yoshitaka Sakata
Takao KatsuraTakao Katsura
Takao Katsura
Ahmed SerageldinAhmed Serageldin
Ahmed Serageldin
Katsunori NaganoKatsunori Nagano
Katsunori Nagano
MOMotoaki Ooe
Motoaki Ooe
The variability of ground thermal conductivity, based on underground conditions, is often ignored during the design of ground-source heat pump systems. This study shows a field evidence of such site-scale variations through thermal response tests in eight borehole heat exchangers aligned at a site on a terrace along the foothills of mountains in northern Japan. Conventional analysis of the overall ground thermal conductivity along the total installation length finds that the value at one borehole heat exchanger is 2.5 times that at the other seven boreholes. History matching analysis of underground distributed temperature measurements generates vertical partial ground thermal conductivity data for four depth layers. Based on the moving line heat source theory, the partial values are generally within a narrow range expected for gravel deposits. Darcy velocities of groundwater are estimated to be 74–204 m/y at the borehole with high conductivity, increasing in the shallow layers above a depth of 41 m. In contrast, the velocities at the other seven boreholes are one-to-two orders of magnitude smaller with no trend. These high and low velocity values are considered for the topography and permeability. However, the relatively slow groundwater velocities might not apparently increase the partial conductivity.