(1) Background: Mid-stromal isolated Bowman layer transplantation aims to reduce and stabilize corneal ectasia in patients with advanced, progressive keratoconus. The purpose of this review is to evaluate the effectiveness and safety of this new surgical technique. (2) Methods: Following the PRISMA statement and checklist, we searched Medline, the Cochrane Controlled Trials Register, and Embase and used a broad systematic search strategy according to the Cochrane Collaboration. (3) Results: Eight studies with a total number of 120 eyes of 106 patients met our inclusion criteria. One month after Bowman layer transplantation, patients with keratoconus showed a significant decrease in the measured simulated keratometry (−4.74 D [95% CI −6.79 to −2.69]) and the maximum keratometry (−7.41 D [95% CI −9.64 to −5.19]), which remained significant one year postoperatively (−2.91 D [95% CI −5.29 to −0.53] and −5.80 D [−8.49 to −3.12]). Intra- and postoperative complications were observed in 3% and 9% of the patients, respectively. An estimated success rate of 75% to 85% was achieved by experienced surgeons at 5 to 8 years postoperatively. (4) Conclusions: Bowman layer transplantation may be an effective and safe treatment option in patients with advanced, progressive keratoconus. Additional multicenter prospective interventional studies are needed to confirm these preliminary findings.
6 May 2020 in Graefe's Archive for Clinical and Experimental Ophthalmology
Background: The aim of the study was to compare macular thickness behavior and clinical outcomes after femtosecond laser-assisted cataract surgery (FLACS) versus phacoemulsification conventional surgery (PCS). Methods: Macular Optical Coherence Tomography OCT was analyzed in 42 patients preoperatively, 1 day, 12 days, 4 weeks and 6 weeks postoperatively according to the 9-field Early Treatment Diabetic Retinopathy Study (ETDRS) grid. Clinical findings were collected in both the FLACS group and the PCS group. Results: There was no significant difference in macular thickness between the FLACS and PCS groups (p > 0.05). However, from postoperative day 12 onwards, there was a significant increase in macular thickness observed in both groups (p < 0.001). In the FLACS group, a significant increase in visual acuity was observed on the first postoperative day, as compared to the PCS group (p = 0.006). Conclusions: The use of a low-energy high-frequency femtosecond laser has potentially no effect on postoperative macular thickness. In the FLACS group, visual rehabilitation was significantly faster as compared to the PCS group. No complications occurred intraoperatively in either group.
Background: The purpose of this study is to evaluate the outcome of deep sclerectomy (DS) as a secondary procedure following failed ab-interno XEN gel stent implantation in patients with open-angle glaucoma. Methods: Prospective, single-center, non-randomized, interventional study. Consecutive eyes that underwent mitomycin C (MMC) augmented XEN gel stent surgery, with uncontrolled intraocular pressure (IOP) or signs of disease progression, were included to undergo MMC-augmented DS. Primary efficacy outcome was surgical success, defined as complete when the unmedicated IOP was 12 mmHg or less, or 15 mmHg or less and 20% lower than at the timing of XEN failure and defined as qualified when the IOP fulfilled the same conditions with fewer medications than before deep sclerectomy. Secondary measures were mean reduction in IOP and in the number of medications, and the rates of complications. Results: Seventeen eyes were enrolled with a mean age of 72.1 ± 8.2 years (66.7% women). The mean follow-up was 20.1 ± 4.9 months, with more than 12-month data available from 15 eyes. Following DS, IOP decreased significantly from 22.6 ± 5.3 mmHg to 12.3 ± 5.5 (45.6%; p < 0.001). Antiglaucoma medications dropped from 1.1 ± 0.9 to 0.3 ± 0.7. Complete success was obtained in 40% of eyes using the threshold of 12 mmHg or less and a 20% decrease of IOP, and in 60% using the 15 mmHg or less threshold. Adverse events were observed in 20% of eyes (bleb leakage (13.3%); hypotony (6.7%)). No cases of choroidal detachment or hypotony maculopathy were reported. Conclusions: Failed XEN gel stent implantation does not seem to negatively affect the safety and efficacy of subsequent deep sclerectomy surgery.