In this paper, a sliding-mode control (SMC) strategy is proposed for three-phase grid-tied LCL-filtered voltage source inverters in the natural frame. The SMC in the natural frame is based on controlling the sliding surface functions of phase-legs a and b. The sliding surface function of phase-leg c is obtained from the sliding surface functions of phase-legs a and b. This eliminates the need for sensing capacitor voltage and grid current of phase-leg c. The capacitor voltage references are generated by the proportional-resonant (PR) controllers which result in zero steady-state error in the grid current. The feasibility and performance of the proposed SMC strategy is investigated under steady-state, transient, unbalanced and distorted grid conditions. Experimental results taken from a 9.8kW system are provided to demonstrate the validity of the proposed SMC strategy.
5 September 2019 in IEEE Transactions on Industry Applications
In this article, a four-port solid-state transformer and a control scheme to control the power flow and output voltage are studied, developed, and tested. The converter consists of three ports with H-bridge converters and one port with a diode bridge rectifier. The ports with H-bridge converters are capable of bidirectional power routing as well as reactive power contribution in a volt/Var control scenario. The diode bridge rectifier provides a dc voltage for load connection. Different arrangements for the four transformer windings are analyzed, simulated, and compared to achieve an optimal design. A new control strategy, which uses a combination of phase-shift and duty cycle control, is employed to control the flow of power between the converter branches and to regulate the output voltage. While phase-shift control ensures the balance of power on each port based on a reference value, the duty cycle control keeps the load voltage at a desired voltage level. A high-level control scheme is employed to determine the power references for all ports according to the load demand, generation capacity of the distributed generation system, and state of charge of the energy storage. The performance of the proposed system is validated with simulation and experimental analysis. A prototype is designed and built with 10-kW power rating at each port. The operating frequency of the system is designed at 100 kHz to obtain a very compact size for the whole converter.
This paper proposes a new method to determine the optimal size of a photovoltaic (PV) and battery energy storage system (BESS) in a grid-connected microgrid (MG). Energy cost minimization is selected as an objective function. Optimum BESS and PV size are determined via a novel energy management method and particle swarm optimization (PSO) algorithm to obtain minimum total cost. The MG was designed to use its own energy as much as possible, which is produced from renewable energy resources. Since it is a grid-connected system, it can demand energy from the grid within the determined limit with penalty. It differs from the studies in the literature in terms of optimizing both parameters such as PV and BESS size, being a grid-connected self-contained MG structure and controlling the grid energy by an energy management algorithm and optimizing the parameter via PSO with an energy management system (EMS). Results are compared for different PV and BESS. Moreover, effectiveness of the novel energy management method with PSO is compared with the genetic algorithm, which is the one of the well-known optimization algorithms. The results show that the proposed algorithm can achieve optimum PV and BESS size with minimum cost by using the new energy management method with the PSO algorithm.
7 May 2018 in IEEE Transactions on Sustainable Energy
In this paper, an enhanced Lyapunov-function based control scheme is proposed for three-phase grid-tied LCL-filtered voltage source inverters (VSIs). The grid-tied VSI is modeled in the synchronously rotating dq-frame. Motivated from the energy distribution in the system, an energy-like function (referred to as Lyapunov-function) is defined. Then, Lyapunov-function based control scheme is derived, which guarantees the global stability of the system. However, the derived Lyapunov-function based control scheme with single-loop cannot exhibit a satisfactory damping performance due to the poles located near imaginary axis. Therefore, an enhanced Lyapunov-function based control scheme is proposed by adding a second loop into the control variable. Unlike the existing control schemes where cross-coupling interaction exists between d and q-axes actual currents, the cross coupling in the proposed control scheme is dependent on the inverter current references. The performance and validity of the proposed control scheme are verified by computer simulations and experimental results.
29 March 2022 in IEEE Transactions on Industry Applications
In this article, a new topology for a grid-connected solar photovoltaic inverter for the direct connection to the medium-voltage grid is proposed. This topology employs an LLC resonant converter with a high-frequency (HF) isolation transformer in the dc–dc stage. The output of the dc–dc stage is a rectified sine wave voltage and current at the line frequency. An unfolder inverter interfaces between this dc stage and the grid. A combined phase-shift and frequency control method is used to control the LLC resonant converter. The phase-shift angle and switching frequency values of the LLC resonant converter are regulated to track the reference current signal for the whole operation range. The Lagrange multiplier method is applied to find the optimal trajectory to calculate the optimal phase-shift angle and switching frequency pairs for any operation condition by considering power converter and HF transformer losses to achieve the highest efficiency at a varying current. The transformer leakage and magnetization inductances are properly designed to provide a zero-voltage switching (ZVS) for a wide operation area, and additional resonant inductor requirement is removed. The LLC converter operates in a ZVS region except in a narrow band around the zero-current crossings of the inverter output. Using an HF transformer in the LLC resonant converter, a bulky line frequency transformer requirement is eliminated, and thus, a more compact and efficient design is obtained. The proposed topology is validated by the simulation and experimental results.
1 March 2022 in CES Transactions on Electrical Machines and Systems
The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies. For that, the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems. The objective of this paper is to present the design, implementation, and testing of a compact multi-port solid-state transformer for microgrid integration applications. The proposed system has a four-port transformer and four converters connected to the ports. The transformer has four windings integrated on a single common core. Thus, it can integrate different renewable energy resources and energy storage systems. Each port has a rated power of 25kW, and the switching frequency is pushed to 50kHz. The ports are chosen to represent a realistic industrial microgrid model consisting of grid, energy storage system, photovoltaic system, and load. The grid port is designed to operate at 4.16kVAC corresponding to 7.2kV DC bus voltage, while the other three ports operate at 500VDC. Moreover, the grid, energy storage and photovoltaic ports are active ports with dual active bridge topologies, while the load port is a passive port with full bridge rectifier one. The proposed design is first validated with simulation results, and then the proposed transformer is implemented and tested. Experimental results show that the designed system is suitable for 4.16kVAC medium voltage grid integration.